Establishment of ex vivo calibration curve for X-ray induced “dicentric + ring” and micronuclei in human peripheral lymphocytes for biodosimetry during radiological emergencies, and validation with dose blinded samples

In the modern developing society, application of radiation has increased extensively. With significant improvement in the radiation protection practices, exposure to human could be minimized substantially, but cannot be avoided completely. Assessment of exposure is essential for regulatory decision...

Descripción completa

Detalles Bibliográficos
Autores principales: Vijayalakshmi, J., Chaurasia, Rajesh Kumar, Srinivas, K. Satish, Vijayalakshmi, K., Paul, Solomon F.D., Bhat, N.N., Sapra, B.K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10361230/
https://www.ncbi.nlm.nih.gov/pubmed/37484390
http://dx.doi.org/10.1016/j.heliyon.2023.e17068
_version_ 1785076173142753280
author Vijayalakshmi, J.
Chaurasia, Rajesh Kumar
Srinivas, K. Satish
Vijayalakshmi, K.
Paul, Solomon F.D.
Bhat, N.N.
Sapra, B.K.
author_facet Vijayalakshmi, J.
Chaurasia, Rajesh Kumar
Srinivas, K. Satish
Vijayalakshmi, K.
Paul, Solomon F.D.
Bhat, N.N.
Sapra, B.K.
author_sort Vijayalakshmi, J.
collection PubMed
description In the modern developing society, application of radiation has increased extensively. With significant improvement in the radiation protection practices, exposure to human could be minimized substantially, but cannot be avoided completely. Assessment of exposure is essential for regulatory decision and medical management as applicable. Until now, cytogenetic changes have served as surrogate marker of radiation exposure and have been extensively employed for biological dose estimation of various planned and unplanned exposures. Dicentric Chromosomal Aberration (DCA) is radiation specific and is considered as gold standard, micronucleus is not very specific to radiation and is considered as an alternative method for biodosimetry. In this study dose response curves were generated for X-ray induced “dicentric + ring” and micronuclei, in lymphocytes of three healthy volunteers [2 females (age 22, 23 years) and 1 male (24 year)]. The blood samples were irradiated with X-ray using LINAC (energy 6 MV, dose rate 6 Gy/min), in the dose range of 0–5Gy. Irradiated blood samples were cultured and processed to harvest metaphases, as per standard procedures recommended by International Atomic Energy Agency. Pooled data obtained from all the three volunteers, were in agreement with Poisson distribution for “dicentric + ring”, however over dispersion was observed for micronuclei. Data (“dicentric + ring” and micronuclei) were fitted by linear quadratic model of the expression Y[bond, double bond]C + αD + βD(2) using Dose Estimate software, version 5.2. The data fit has resulted in linear coefficient α = 0.0006 (±0.0068) “dicentric + ring” cell(−1) Gy(−1) and quadratic coefficient β = 0.0619 (±0.0043) “dicentric + ring” cell(−1) Gy(−2) for “dicentric + ring” and linear coefficient α = 0.0459 ± (0.0038) micronuclei cell(−1) Gy(−1) and quadratic coefficient β = 0.0185 ± (0.0010) micronuclei cell(−1) Gy(−2) for micronuclei, respectively. Background frequencies for “dicentric + ring” and micronuclei were 0.0006 ± 0.0004 and 0.0077 ± 0.0012 cell(−1), respectively. Established curves were validated, by reconstructing the doses of 8 dose blinded samples (4 by DCA and 4 by CBMN) using coefficients generated here. Estimated doses were within the variation of 0.9–16% for “dicentric + ring” and 21.7–31.2% for micronuclei respectively. These established curves have potential to be employed for biodosimetry of occupational, clinical and accidental exposures, for initial triage and medical management.
format Online
Article
Text
id pubmed-10361230
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-103612302023-07-22 Establishment of ex vivo calibration curve for X-ray induced “dicentric + ring” and micronuclei in human peripheral lymphocytes for biodosimetry during radiological emergencies, and validation with dose blinded samples Vijayalakshmi, J. Chaurasia, Rajesh Kumar Srinivas, K. Satish Vijayalakshmi, K. Paul, Solomon F.D. Bhat, N.N. Sapra, B.K. Heliyon Research Article In the modern developing society, application of radiation has increased extensively. With significant improvement in the radiation protection practices, exposure to human could be minimized substantially, but cannot be avoided completely. Assessment of exposure is essential for regulatory decision and medical management as applicable. Until now, cytogenetic changes have served as surrogate marker of radiation exposure and have been extensively employed for biological dose estimation of various planned and unplanned exposures. Dicentric Chromosomal Aberration (DCA) is radiation specific and is considered as gold standard, micronucleus is not very specific to radiation and is considered as an alternative method for biodosimetry. In this study dose response curves were generated for X-ray induced “dicentric + ring” and micronuclei, in lymphocytes of three healthy volunteers [2 females (age 22, 23 years) and 1 male (24 year)]. The blood samples were irradiated with X-ray using LINAC (energy 6 MV, dose rate 6 Gy/min), in the dose range of 0–5Gy. Irradiated blood samples were cultured and processed to harvest metaphases, as per standard procedures recommended by International Atomic Energy Agency. Pooled data obtained from all the three volunteers, were in agreement with Poisson distribution for “dicentric + ring”, however over dispersion was observed for micronuclei. Data (“dicentric + ring” and micronuclei) were fitted by linear quadratic model of the expression Y[bond, double bond]C + αD + βD(2) using Dose Estimate software, version 5.2. The data fit has resulted in linear coefficient α = 0.0006 (±0.0068) “dicentric + ring” cell(−1) Gy(−1) and quadratic coefficient β = 0.0619 (±0.0043) “dicentric + ring” cell(−1) Gy(−2) for “dicentric + ring” and linear coefficient α = 0.0459 ± (0.0038) micronuclei cell(−1) Gy(−1) and quadratic coefficient β = 0.0185 ± (0.0010) micronuclei cell(−1) Gy(−2) for micronuclei, respectively. Background frequencies for “dicentric + ring” and micronuclei were 0.0006 ± 0.0004 and 0.0077 ± 0.0012 cell(−1), respectively. Established curves were validated, by reconstructing the doses of 8 dose blinded samples (4 by DCA and 4 by CBMN) using coefficients generated here. Estimated doses were within the variation of 0.9–16% for “dicentric + ring” and 21.7–31.2% for micronuclei respectively. These established curves have potential to be employed for biodosimetry of occupational, clinical and accidental exposures, for initial triage and medical management. Elsevier 2023-06-07 /pmc/articles/PMC10361230/ /pubmed/37484390 http://dx.doi.org/10.1016/j.heliyon.2023.e17068 Text en © 2023 Published by Elsevier Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Vijayalakshmi, J.
Chaurasia, Rajesh Kumar
Srinivas, K. Satish
Vijayalakshmi, K.
Paul, Solomon F.D.
Bhat, N.N.
Sapra, B.K.
Establishment of ex vivo calibration curve for X-ray induced “dicentric + ring” and micronuclei in human peripheral lymphocytes for biodosimetry during radiological emergencies, and validation with dose blinded samples
title Establishment of ex vivo calibration curve for X-ray induced “dicentric + ring” and micronuclei in human peripheral lymphocytes for biodosimetry during radiological emergencies, and validation with dose blinded samples
title_full Establishment of ex vivo calibration curve for X-ray induced “dicentric + ring” and micronuclei in human peripheral lymphocytes for biodosimetry during radiological emergencies, and validation with dose blinded samples
title_fullStr Establishment of ex vivo calibration curve for X-ray induced “dicentric + ring” and micronuclei in human peripheral lymphocytes for biodosimetry during radiological emergencies, and validation with dose blinded samples
title_full_unstemmed Establishment of ex vivo calibration curve for X-ray induced “dicentric + ring” and micronuclei in human peripheral lymphocytes for biodosimetry during radiological emergencies, and validation with dose blinded samples
title_short Establishment of ex vivo calibration curve for X-ray induced “dicentric + ring” and micronuclei in human peripheral lymphocytes for biodosimetry during radiological emergencies, and validation with dose blinded samples
title_sort establishment of ex vivo calibration curve for x-ray induced “dicentric + ring” and micronuclei in human peripheral lymphocytes for biodosimetry during radiological emergencies, and validation with dose blinded samples
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10361230/
https://www.ncbi.nlm.nih.gov/pubmed/37484390
http://dx.doi.org/10.1016/j.heliyon.2023.e17068
work_keys_str_mv AT vijayalakshmij establishmentofexvivocalibrationcurveforxrayinduceddicentricringandmicronucleiinhumanperipherallymphocytesforbiodosimetryduringradiologicalemergenciesandvalidationwithdoseblindedsamples
AT chaurasiarajeshkumar establishmentofexvivocalibrationcurveforxrayinduceddicentricringandmicronucleiinhumanperipherallymphocytesforbiodosimetryduringradiologicalemergenciesandvalidationwithdoseblindedsamples
AT srinivasksatish establishmentofexvivocalibrationcurveforxrayinduceddicentricringandmicronucleiinhumanperipherallymphocytesforbiodosimetryduringradiologicalemergenciesandvalidationwithdoseblindedsamples
AT vijayalakshmik establishmentofexvivocalibrationcurveforxrayinduceddicentricringandmicronucleiinhumanperipherallymphocytesforbiodosimetryduringradiologicalemergenciesandvalidationwithdoseblindedsamples
AT paulsolomonfd establishmentofexvivocalibrationcurveforxrayinduceddicentricringandmicronucleiinhumanperipherallymphocytesforbiodosimetryduringradiologicalemergenciesandvalidationwithdoseblindedsamples
AT bhatnn establishmentofexvivocalibrationcurveforxrayinduceddicentricringandmicronucleiinhumanperipherallymphocytesforbiodosimetryduringradiologicalemergenciesandvalidationwithdoseblindedsamples
AT saprabk establishmentofexvivocalibrationcurveforxrayinduceddicentricringandmicronucleiinhumanperipherallymphocytesforbiodosimetryduringradiologicalemergenciesandvalidationwithdoseblindedsamples