Cargando…

The optimum condition of the toluidine red unheated serum test for the replacement of the venereal disease research laboratory test in cerebrospinal fluid for neurosyphilis diagnosis

BACKGROUND: The cerebrospinal fluid (CSF) venereal disease research laboratory (VDRL) test remains the standard for the laboratory diagnosis of neurosyphilis. The toluidine red unheated serum test (TRUST) is an alternative to the VDRL test as a serological test for syphilis, but it lacks guidelines...

Descripción completa

Detalles Bibliográficos
Autores principales: Xiao, Yao, Tong, Man-Li, Yang, Yang, Gu, Wei-Ming, Liu, Li-Li, Yang, Tian-Ci
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10361306/
https://www.ncbi.nlm.nih.gov/pubmed/37484402
http://dx.doi.org/10.1016/j.heliyon.2023.e17157
_version_ 1785076189631610880
author Xiao, Yao
Tong, Man-Li
Yang, Yang
Gu, Wei-Ming
Liu, Li-Li
Yang, Tian-Ci
author_facet Xiao, Yao
Tong, Man-Li
Yang, Yang
Gu, Wei-Ming
Liu, Li-Li
Yang, Tian-Ci
author_sort Xiao, Yao
collection PubMed
description BACKGROUND: The cerebrospinal fluid (CSF) venereal disease research laboratory (VDRL) test remains the standard for the laboratory diagnosis of neurosyphilis. The toluidine red unheated serum test (TRUST) is an alternative to the VDRL test as a serological test for syphilis, but it lacks guidelines for its use in CSF for neurosyphilis diagnosis. METHODS: A total of 210 suspected neurosyphilis patients were included, consisting of 124 neurosyphilis patients and 86 syphilis/non-neurosyphilis patients. The TRUST was modified into the CSF-TRUST-10 test with 10 μL of antigen by referring to the CSF-VDRL test, and the CSF-TRUST-17 test with 17 μL of antigen by referring to its procedures in serum. The diagnostic performance of the CSF-TRUST-10 and CSF-TRUST-17 tests and the concordance between them and the CSF-VDRL test were evaluated. RESULTS: The diagnostic performance of the CSF-TRUST-10 and CSF-TRUST-17 tests for diagnosing neurosyphilis were comparable to the CSF-VDRL test, as well as the positive rate. The agreement rate was 98.7% between the qualitative CSF-TRUST-10 and CSF-VDRL tests. A total of 91.4% of the quantitative CSF-TRUST-10 results were consistent with the CSF-VDRL test, and the discordant results were no more than two titres. The agreement rate was 98.1% between the qualitative CSF-TRUST-17 and CSF-VDRL tests and 87.6% between the quantitative CSF-TRUST-17 and CSF-VDRL tests. CONCLUSIONS: The CSF-TRUST with 10 μL of antigen could be an alternative for the CSF-VDRL test for neurosyphilis diagnosis. Our results provide a basis for using the TRUST to guide the diagnosis of neurosyphilis.
format Online
Article
Text
id pubmed-10361306
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-103613062023-07-22 The optimum condition of the toluidine red unheated serum test for the replacement of the venereal disease research laboratory test in cerebrospinal fluid for neurosyphilis diagnosis Xiao, Yao Tong, Man-Li Yang, Yang Gu, Wei-Ming Liu, Li-Li Yang, Tian-Ci Heliyon Research Article BACKGROUND: The cerebrospinal fluid (CSF) venereal disease research laboratory (VDRL) test remains the standard for the laboratory diagnosis of neurosyphilis. The toluidine red unheated serum test (TRUST) is an alternative to the VDRL test as a serological test for syphilis, but it lacks guidelines for its use in CSF for neurosyphilis diagnosis. METHODS: A total of 210 suspected neurosyphilis patients were included, consisting of 124 neurosyphilis patients and 86 syphilis/non-neurosyphilis patients. The TRUST was modified into the CSF-TRUST-10 test with 10 μL of antigen by referring to the CSF-VDRL test, and the CSF-TRUST-17 test with 17 μL of antigen by referring to its procedures in serum. The diagnostic performance of the CSF-TRUST-10 and CSF-TRUST-17 tests and the concordance between them and the CSF-VDRL test were evaluated. RESULTS: The diagnostic performance of the CSF-TRUST-10 and CSF-TRUST-17 tests for diagnosing neurosyphilis were comparable to the CSF-VDRL test, as well as the positive rate. The agreement rate was 98.7% between the qualitative CSF-TRUST-10 and CSF-VDRL tests. A total of 91.4% of the quantitative CSF-TRUST-10 results were consistent with the CSF-VDRL test, and the discordant results were no more than two titres. The agreement rate was 98.1% between the qualitative CSF-TRUST-17 and CSF-VDRL tests and 87.6% between the quantitative CSF-TRUST-17 and CSF-VDRL tests. CONCLUSIONS: The CSF-TRUST with 10 μL of antigen could be an alternative for the CSF-VDRL test for neurosyphilis diagnosis. Our results provide a basis for using the TRUST to guide the diagnosis of neurosyphilis. Elsevier 2023-06-12 /pmc/articles/PMC10361306/ /pubmed/37484402 http://dx.doi.org/10.1016/j.heliyon.2023.e17157 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Xiao, Yao
Tong, Man-Li
Yang, Yang
Gu, Wei-Ming
Liu, Li-Li
Yang, Tian-Ci
The optimum condition of the toluidine red unheated serum test for the replacement of the venereal disease research laboratory test in cerebrospinal fluid for neurosyphilis diagnosis
title The optimum condition of the toluidine red unheated serum test for the replacement of the venereal disease research laboratory test in cerebrospinal fluid for neurosyphilis diagnosis
title_full The optimum condition of the toluidine red unheated serum test for the replacement of the venereal disease research laboratory test in cerebrospinal fluid for neurosyphilis diagnosis
title_fullStr The optimum condition of the toluidine red unheated serum test for the replacement of the venereal disease research laboratory test in cerebrospinal fluid for neurosyphilis diagnosis
title_full_unstemmed The optimum condition of the toluidine red unheated serum test for the replacement of the venereal disease research laboratory test in cerebrospinal fluid for neurosyphilis diagnosis
title_short The optimum condition of the toluidine red unheated serum test for the replacement of the venereal disease research laboratory test in cerebrospinal fluid for neurosyphilis diagnosis
title_sort optimum condition of the toluidine red unheated serum test for the replacement of the venereal disease research laboratory test in cerebrospinal fluid for neurosyphilis diagnosis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10361306/
https://www.ncbi.nlm.nih.gov/pubmed/37484402
http://dx.doi.org/10.1016/j.heliyon.2023.e17157
work_keys_str_mv AT xiaoyao theoptimumconditionofthetoluidineredunheatedserumtestforthereplacementofthevenerealdiseaseresearchlaboratorytestincerebrospinalfluidforneurosyphilisdiagnosis
AT tongmanli theoptimumconditionofthetoluidineredunheatedserumtestforthereplacementofthevenerealdiseaseresearchlaboratorytestincerebrospinalfluidforneurosyphilisdiagnosis
AT yangyang theoptimumconditionofthetoluidineredunheatedserumtestforthereplacementofthevenerealdiseaseresearchlaboratorytestincerebrospinalfluidforneurosyphilisdiagnosis
AT guweiming theoptimumconditionofthetoluidineredunheatedserumtestforthereplacementofthevenerealdiseaseresearchlaboratorytestincerebrospinalfluidforneurosyphilisdiagnosis
AT liulili theoptimumconditionofthetoluidineredunheatedserumtestforthereplacementofthevenerealdiseaseresearchlaboratorytestincerebrospinalfluidforneurosyphilisdiagnosis
AT yangtianci theoptimumconditionofthetoluidineredunheatedserumtestforthereplacementofthevenerealdiseaseresearchlaboratorytestincerebrospinalfluidforneurosyphilisdiagnosis
AT xiaoyao optimumconditionofthetoluidineredunheatedserumtestforthereplacementofthevenerealdiseaseresearchlaboratorytestincerebrospinalfluidforneurosyphilisdiagnosis
AT tongmanli optimumconditionofthetoluidineredunheatedserumtestforthereplacementofthevenerealdiseaseresearchlaboratorytestincerebrospinalfluidforneurosyphilisdiagnosis
AT yangyang optimumconditionofthetoluidineredunheatedserumtestforthereplacementofthevenerealdiseaseresearchlaboratorytestincerebrospinalfluidforneurosyphilisdiagnosis
AT guweiming optimumconditionofthetoluidineredunheatedserumtestforthereplacementofthevenerealdiseaseresearchlaboratorytestincerebrospinalfluidforneurosyphilisdiagnosis
AT liulili optimumconditionofthetoluidineredunheatedserumtestforthereplacementofthevenerealdiseaseresearchlaboratorytestincerebrospinalfluidforneurosyphilisdiagnosis
AT yangtianci optimumconditionofthetoluidineredunheatedserumtestforthereplacementofthevenerealdiseaseresearchlaboratorytestincerebrospinalfluidforneurosyphilisdiagnosis