A novel device with pedicular anchorage provides better biomechanical properties than balloon kyphoplasty for the treatment of vertebral compression fractures

PURPOSE: To compare the biomechanical behavior of vertebrae with vertebral compression fractures (VCF) treated by a novel system with pedicular anchorage (dowelplasty) versus balloon kyphoplasty. METHODS: Four cadaveric spines (T12-L5) were harvested, cleaned from soft tissues, and separated into ve...

Descripción completa

Detalles Bibliográficos
Autores principales: Le Huec, Jean-Charles, Droulout, Thomas, Boue, Lisa, Dejour, Edouard, Ramos-Pascual, Sonia, Bourret, Stephane
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10361952/
https://www.ncbi.nlm.nih.gov/pubmed/37477733
http://dx.doi.org/10.1186/s40634-023-00635-7
Descripción
Sumario:PURPOSE: To compare the biomechanical behavior of vertebrae with vertebral compression fractures (VCF) treated by a novel system with pedicular anchorage (dowelplasty) versus balloon kyphoplasty. METHODS: Four cadaveric spines (T12-L5) were harvested, cleaned from soft tissues, and separated into vertebrae. Axial compressive loads were applied to each vertebra until a VCF was generated. Half of the vertebrae (n = 11) were instrumented using the “dowelplasty” system, consisting of a hollow titanium dowel anchored into the pedicle, through which a cannulated titanium nail is inserted and locked and through which cement is injected. The other half (n = 11) were instrumented using balloon kyphoplasty. Axial compressive loads were re-applied to each vertebra until fracture. Fracture load and fracture energy were calculated from load–displacement data for the pre- and post-treatment states. RESULTS: Compared to balloon kyphoplasty, dowelplasty granted greater net change in fracture load (373N; 95%CI,-331–1076N) and fracture energy (755Nmm; 95%CI,-563–2072Nmm). A sensitivity analysis was performed without L4 and L5 vertebrae from the dowelplasty group, since the length of the cannulated nails was too short for these vertebrae: compared to balloon kyphoplasty, dowelplasty granted an even greater net change in fracture load (680N; 95%CI,-96–1457N) and fracture energy (1274Nmm; 95%CI,-233–2781Nmm). CONCLUSION: Treating VCFs with dowelplasty grants increased fracture load and fracture energy compared to the pre-treatment state. Furthermore, dowelplasty grants greater improvement in fracture load and fracture energy compared to balloon kyphoplasty, which suggests that dowelplasty may be a good alternative for the treatment of VCF. LEVEL OF EVIDENCE: level IV.