Cargando…

Development of non-electrically controlled SalivaDirect LAMP (NEC-SD-LAMP), a new nonelectrical infectious disease testing method

In this study, non-electrically controlled SalivaDirect loop-mediated isothermal amplification (NEC-SD-LAMP), which can detect infections by amplifying viral DNA expression in saliva without using electrical control systems, was developed. By this method, only by adding water to the device, viral DN...

Descripción completa

Detalles Bibliográficos
Autores principales: Kimura, Yusuke, Ikeuchi, Masashi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10362045/
https://www.ncbi.nlm.nih.gov/pubmed/37479724
http://dx.doi.org/10.1038/s41598-023-38800-8
_version_ 1785076335612264448
author Kimura, Yusuke
Ikeuchi, Masashi
author_facet Kimura, Yusuke
Ikeuchi, Masashi
author_sort Kimura, Yusuke
collection PubMed
description In this study, non-electrically controlled SalivaDirect loop-mediated isothermal amplification (NEC-SD-LAMP), which can detect infections by amplifying viral DNA expression in saliva without using electrical control systems, was developed. By this method, only by adding water to the device, viral DNA was extracted from saliva using SalivaDirect, the extracted DNA was amplified via loop-mediated isothermal amplification (LAMP), and the results were visually confirmed. Melting palmitic acid maintained the optimal temperature for the LAMP reaction, as the temperature of palmitic acid is maintained at 62.9 °C, its melting point. By exploiting the proximity of the melting point to the optimal temperature for LAMP, LAMP can be performed without electricity. We detected several viruses in the saliva using this method. NEC-SD-LAMP could clearly distinguish 3 types of viral DNA, indicating the high specificity of this reaction. Furthermore, the viral concentration detection limit of the device was 2 copies per µL, indicating that it is possible to detect DNA viral infections in saliva even before the onset of viral infection.
format Online
Article
Text
id pubmed-10362045
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-103620452023-07-23 Development of non-electrically controlled SalivaDirect LAMP (NEC-SD-LAMP), a new nonelectrical infectious disease testing method Kimura, Yusuke Ikeuchi, Masashi Sci Rep Article In this study, non-electrically controlled SalivaDirect loop-mediated isothermal amplification (NEC-SD-LAMP), which can detect infections by amplifying viral DNA expression in saliva without using electrical control systems, was developed. By this method, only by adding water to the device, viral DNA was extracted from saliva using SalivaDirect, the extracted DNA was amplified via loop-mediated isothermal amplification (LAMP), and the results were visually confirmed. Melting palmitic acid maintained the optimal temperature for the LAMP reaction, as the temperature of palmitic acid is maintained at 62.9 °C, its melting point. By exploiting the proximity of the melting point to the optimal temperature for LAMP, LAMP can be performed without electricity. We detected several viruses in the saliva using this method. NEC-SD-LAMP could clearly distinguish 3 types of viral DNA, indicating the high specificity of this reaction. Furthermore, the viral concentration detection limit of the device was 2 copies per µL, indicating that it is possible to detect DNA viral infections in saliva even before the onset of viral infection. Nature Publishing Group UK 2023-07-21 /pmc/articles/PMC10362045/ /pubmed/37479724 http://dx.doi.org/10.1038/s41598-023-38800-8 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Kimura, Yusuke
Ikeuchi, Masashi
Development of non-electrically controlled SalivaDirect LAMP (NEC-SD-LAMP), a new nonelectrical infectious disease testing method
title Development of non-electrically controlled SalivaDirect LAMP (NEC-SD-LAMP), a new nonelectrical infectious disease testing method
title_full Development of non-electrically controlled SalivaDirect LAMP (NEC-SD-LAMP), a new nonelectrical infectious disease testing method
title_fullStr Development of non-electrically controlled SalivaDirect LAMP (NEC-SD-LAMP), a new nonelectrical infectious disease testing method
title_full_unstemmed Development of non-electrically controlled SalivaDirect LAMP (NEC-SD-LAMP), a new nonelectrical infectious disease testing method
title_short Development of non-electrically controlled SalivaDirect LAMP (NEC-SD-LAMP), a new nonelectrical infectious disease testing method
title_sort development of non-electrically controlled salivadirect lamp (nec-sd-lamp), a new nonelectrical infectious disease testing method
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10362045/
https://www.ncbi.nlm.nih.gov/pubmed/37479724
http://dx.doi.org/10.1038/s41598-023-38800-8
work_keys_str_mv AT kimurayusuke developmentofnonelectricallycontrolledsalivadirectlampnecsdlampanewnonelectricalinfectiousdiseasetestingmethod
AT ikeuchimasashi developmentofnonelectricallycontrolledsalivadirectlampnecsdlampanewnonelectricalinfectiousdiseasetestingmethod