Cargando…

CPA-Cas12a-based lateral flow strip for portable assay of Methicillin-resistant Staphylococcus aureus in clinical sample

The rapid and accurate identification of methicillin-resistant Staphylococcus aureus at an early antibiotic therapy stage would be benefit to disease diagnosis and antibiotic selection. Herein, we integrated cross-priming amplification (CPA) and CRISPR/Cas 12a (designated as CPA-Cas 12a) systems to...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Jiangling, Huang, Yu, Ding, Xiaojuan, Kang, Lina, Wang, Xiaoliang, Li, Dandan, Cheng, Wei, Liu, Gang, Xue, Jianjiang, Ding, Shijia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10362775/
https://www.ncbi.nlm.nih.gov/pubmed/37481551
http://dx.doi.org/10.1186/s12951-023-02002-1
_version_ 1785076503814340608
author Wu, Jiangling
Huang, Yu
Ding, Xiaojuan
Kang, Lina
Wang, Xiaoliang
Li, Dandan
Cheng, Wei
Liu, Gang
Xue, Jianjiang
Ding, Shijia
author_facet Wu, Jiangling
Huang, Yu
Ding, Xiaojuan
Kang, Lina
Wang, Xiaoliang
Li, Dandan
Cheng, Wei
Liu, Gang
Xue, Jianjiang
Ding, Shijia
author_sort Wu, Jiangling
collection PubMed
description The rapid and accurate identification of methicillin-resistant Staphylococcus aureus at an early antibiotic therapy stage would be benefit to disease diagnosis and antibiotic selection. Herein, we integrated cross-priming amplification (CPA) and CRISPR/Cas 12a (designated as CPA-Cas 12a) systems to establish a sensitive and efficient lateral flow assay to detect methicillin-resistant Staphylococcus aureus. This assay relies on the CPA isothermal nucleic acid amplification strategy which can amplify the DNA extracted from Staphylococcus aureus and accompanying the indiscriminately trans-cleavage process of Cas 12a/CrRNA duplex after recognizing specific sequence. Taking the advantage of reporter and high turnover Cas 12a activity, a dramatic change in response was achieved to produce a significant increase in the analytical sensitivity. The signal conversion and output were realized using a lateral flow strip to achieve field-deployable detection. Furthermore, this bioassay was accommodated with a microfluidic device to realize automatically portable detection. This proposed assay completed within 30 min with the detection limit of 5 CFU mL(-1), was verified by testing bacterial suspension and 202 clinical samples. Given the high sensitivity, specificity and efficiency, this colorimetric readout assay through strip could be further promoted to the clinical diagnosis, clinical medication of multidrug-resistant bacteria. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12951-023-02002-1.
format Online
Article
Text
id pubmed-10362775
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-103627752023-07-23 CPA-Cas12a-based lateral flow strip for portable assay of Methicillin-resistant Staphylococcus aureus in clinical sample Wu, Jiangling Huang, Yu Ding, Xiaojuan Kang, Lina Wang, Xiaoliang Li, Dandan Cheng, Wei Liu, Gang Xue, Jianjiang Ding, Shijia J Nanobiotechnology Research The rapid and accurate identification of methicillin-resistant Staphylococcus aureus at an early antibiotic therapy stage would be benefit to disease diagnosis and antibiotic selection. Herein, we integrated cross-priming amplification (CPA) and CRISPR/Cas 12a (designated as CPA-Cas 12a) systems to establish a sensitive and efficient lateral flow assay to detect methicillin-resistant Staphylococcus aureus. This assay relies on the CPA isothermal nucleic acid amplification strategy which can amplify the DNA extracted from Staphylococcus aureus and accompanying the indiscriminately trans-cleavage process of Cas 12a/CrRNA duplex after recognizing specific sequence. Taking the advantage of reporter and high turnover Cas 12a activity, a dramatic change in response was achieved to produce a significant increase in the analytical sensitivity. The signal conversion and output were realized using a lateral flow strip to achieve field-deployable detection. Furthermore, this bioassay was accommodated with a microfluidic device to realize automatically portable detection. This proposed assay completed within 30 min with the detection limit of 5 CFU mL(-1), was verified by testing bacterial suspension and 202 clinical samples. Given the high sensitivity, specificity and efficiency, this colorimetric readout assay through strip could be further promoted to the clinical diagnosis, clinical medication of multidrug-resistant bacteria. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12951-023-02002-1. BioMed Central 2023-07-22 /pmc/articles/PMC10362775/ /pubmed/37481551 http://dx.doi.org/10.1186/s12951-023-02002-1 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Wu, Jiangling
Huang, Yu
Ding, Xiaojuan
Kang, Lina
Wang, Xiaoliang
Li, Dandan
Cheng, Wei
Liu, Gang
Xue, Jianjiang
Ding, Shijia
CPA-Cas12a-based lateral flow strip for portable assay of Methicillin-resistant Staphylococcus aureus in clinical sample
title CPA-Cas12a-based lateral flow strip for portable assay of Methicillin-resistant Staphylococcus aureus in clinical sample
title_full CPA-Cas12a-based lateral flow strip for portable assay of Methicillin-resistant Staphylococcus aureus in clinical sample
title_fullStr CPA-Cas12a-based lateral flow strip for portable assay of Methicillin-resistant Staphylococcus aureus in clinical sample
title_full_unstemmed CPA-Cas12a-based lateral flow strip for portable assay of Methicillin-resistant Staphylococcus aureus in clinical sample
title_short CPA-Cas12a-based lateral flow strip for portable assay of Methicillin-resistant Staphylococcus aureus in clinical sample
title_sort cpa-cas12a-based lateral flow strip for portable assay of methicillin-resistant staphylococcus aureus in clinical sample
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10362775/
https://www.ncbi.nlm.nih.gov/pubmed/37481551
http://dx.doi.org/10.1186/s12951-023-02002-1
work_keys_str_mv AT wujiangling cpacas12abasedlateralflowstripforportableassayofmethicillinresistantstaphylococcusaureusinclinicalsample
AT huangyu cpacas12abasedlateralflowstripforportableassayofmethicillinresistantstaphylococcusaureusinclinicalsample
AT dingxiaojuan cpacas12abasedlateralflowstripforportableassayofmethicillinresistantstaphylococcusaureusinclinicalsample
AT kanglina cpacas12abasedlateralflowstripforportableassayofmethicillinresistantstaphylococcusaureusinclinicalsample
AT wangxiaoliang cpacas12abasedlateralflowstripforportableassayofmethicillinresistantstaphylococcusaureusinclinicalsample
AT lidandan cpacas12abasedlateralflowstripforportableassayofmethicillinresistantstaphylococcusaureusinclinicalsample
AT chengwei cpacas12abasedlateralflowstripforportableassayofmethicillinresistantstaphylococcusaureusinclinicalsample
AT liugang cpacas12abasedlateralflowstripforportableassayofmethicillinresistantstaphylococcusaureusinclinicalsample
AT xuejianjiang cpacas12abasedlateralflowstripforportableassayofmethicillinresistantstaphylococcusaureusinclinicalsample
AT dingshijia cpacas12abasedlateralflowstripforportableassayofmethicillinresistantstaphylococcusaureusinclinicalsample