Cargando…

Evaluation of the Efficiency and Safety of a 27-Gauge 20,000 Cuts per Minute Vitreous Cutter

PURPOSE: The aim of this study was to evaluate the efficiency and safety of a 27-gauge (G) 20,000 cuts per minute (cpm) vitreous cutter in clinical settings. PATIENTS AND METHODS: This was a retrospective and observational study of 40 eyes of 40 patients with idiopathic epiretinal membrane (ERM). Tw...

Descripción completa

Detalles Bibliográficos
Autores principales: Doi, Yuta, Muraoka, Yuki, Tsujikawa, Akitaka
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10362866/
https://www.ncbi.nlm.nih.gov/pubmed/37483843
http://dx.doi.org/10.2147/OPTH.S418371
_version_ 1785076525490503680
author Doi, Yuta
Muraoka, Yuki
Tsujikawa, Akitaka
author_facet Doi, Yuta
Muraoka, Yuki
Tsujikawa, Akitaka
author_sort Doi, Yuta
collection PubMed
description PURPOSE: The aim of this study was to evaluate the efficiency and safety of a 27-gauge (G) 20,000 cuts per minute (cpm) vitreous cutter in clinical settings. PATIENTS AND METHODS: This was a retrospective and observational study of 40 eyes of 40 patients with idiopathic epiretinal membrane (ERM). Twenty patients (20 eyes) were treated using a 27G 10,000-cpm vitreous cutter (Advanced ULTRAVIT(®) Probe, Alcon), whereas the remaining 20 patients (20 eyes) were treated using a 27G 20,000-cpm cutter (Hypervit(®) dual-blade probe, Alcon). All the surgeries were performed by the same surgeon (YM). The time from the start of vitrectomy to the start of ERM peeling was independently measured by two separate examiners using digital videos of each surgery. The average duration of vitrectomy was calculated for each patient. Additionally, the data of the patients in the two groups were extracted from their medical and surgical records and compared. RESULTS: The time from the initiation of vitrectomy until the start of ERM peeling was 184 ± 56.9 and 152 ± 39.5 s for the 10,000-cpm and 20,000-cpm groups, respectively. The duration of vitrectomy was significantly shorter in the 20,000-cpm group than in the 10,000-cpm group (p = 0.041). Postoperative vitreous hemorrhage was observed in one patient in the 10,000-cpm group, whereas no complications were observed in the 20,000-cpm group. CONCLUSION: In a clinical setting, the 27G 20,000-cpm vitreous cutter may have a higher safety profile and higher efficacy for vitreous removal than that of the 27G 10,000-cpm vitreous cutter.
format Online
Article
Text
id pubmed-10362866
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-103628662023-07-23 Evaluation of the Efficiency and Safety of a 27-Gauge 20,000 Cuts per Minute Vitreous Cutter Doi, Yuta Muraoka, Yuki Tsujikawa, Akitaka Clin Ophthalmol Original Research PURPOSE: The aim of this study was to evaluate the efficiency and safety of a 27-gauge (G) 20,000 cuts per minute (cpm) vitreous cutter in clinical settings. PATIENTS AND METHODS: This was a retrospective and observational study of 40 eyes of 40 patients with idiopathic epiretinal membrane (ERM). Twenty patients (20 eyes) were treated using a 27G 10,000-cpm vitreous cutter (Advanced ULTRAVIT(®) Probe, Alcon), whereas the remaining 20 patients (20 eyes) were treated using a 27G 20,000-cpm cutter (Hypervit(®) dual-blade probe, Alcon). All the surgeries were performed by the same surgeon (YM). The time from the start of vitrectomy to the start of ERM peeling was independently measured by two separate examiners using digital videos of each surgery. The average duration of vitrectomy was calculated for each patient. Additionally, the data of the patients in the two groups were extracted from their medical and surgical records and compared. RESULTS: The time from the initiation of vitrectomy until the start of ERM peeling was 184 ± 56.9 and 152 ± 39.5 s for the 10,000-cpm and 20,000-cpm groups, respectively. The duration of vitrectomy was significantly shorter in the 20,000-cpm group than in the 10,000-cpm group (p = 0.041). Postoperative vitreous hemorrhage was observed in one patient in the 10,000-cpm group, whereas no complications were observed in the 20,000-cpm group. CONCLUSION: In a clinical setting, the 27G 20,000-cpm vitreous cutter may have a higher safety profile and higher efficacy for vitreous removal than that of the 27G 10,000-cpm vitreous cutter. Dove 2023-07-18 /pmc/articles/PMC10362866/ /pubmed/37483843 http://dx.doi.org/10.2147/OPTH.S418371 Text en © 2023 Doi et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Doi, Yuta
Muraoka, Yuki
Tsujikawa, Akitaka
Evaluation of the Efficiency and Safety of a 27-Gauge 20,000 Cuts per Minute Vitreous Cutter
title Evaluation of the Efficiency and Safety of a 27-Gauge 20,000 Cuts per Minute Vitreous Cutter
title_full Evaluation of the Efficiency and Safety of a 27-Gauge 20,000 Cuts per Minute Vitreous Cutter
title_fullStr Evaluation of the Efficiency and Safety of a 27-Gauge 20,000 Cuts per Minute Vitreous Cutter
title_full_unstemmed Evaluation of the Efficiency and Safety of a 27-Gauge 20,000 Cuts per Minute Vitreous Cutter
title_short Evaluation of the Efficiency and Safety of a 27-Gauge 20,000 Cuts per Minute Vitreous Cutter
title_sort evaluation of the efficiency and safety of a 27-gauge 20,000 cuts per minute vitreous cutter
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10362866/
https://www.ncbi.nlm.nih.gov/pubmed/37483843
http://dx.doi.org/10.2147/OPTH.S418371
work_keys_str_mv AT doiyuta evaluationoftheefficiencyandsafetyofa27gauge20000cutsperminutevitreouscutter
AT muraokayuki evaluationoftheefficiencyandsafetyofa27gauge20000cutsperminutevitreouscutter
AT tsujikawaakitaka evaluationoftheefficiencyandsafetyofa27gauge20000cutsperminutevitreouscutter