Cargando…
Variability and reproducibility of multi-echo T(2) relaxometry: Insights from multi-site, multi-session and multi-subject MRI acquisitions
Quantitative magnetic resonance imaging (qMRI) can increase the specificity and sensitivity of conventional weighted MRI to underlying pathology by comparing meaningful physical or chemical parameters, measured in physical units, with normative values acquired in a healthy population. This study foc...
Autores principales: | , , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10365099/ https://www.ncbi.nlm.nih.gov/pubmed/37492668 http://dx.doi.org/10.3389/fradi.2022.930666 |
_version_ | 1785076981122990080 |
---|---|
author | Fischi-Gomez, Elda Girard, Gabriel Koch, Philipp J. Yu, Thomas Pizzolato, Marco Brügger, Julia Piredda, Gian Franco Hilbert, Tom Cadic-Melchior, Andéol G. Beanato, Elena Park, Chang-Hyun Morishita, Takuya Wessel, Maximilian J. Schiavi, Simona Daducci, Alessandro Kober, Tobias Canales-Rodríguez, Erick J. Hummel, Friedhelm C. Thiran, Jean-Philippe |
author_facet | Fischi-Gomez, Elda Girard, Gabriel Koch, Philipp J. Yu, Thomas Pizzolato, Marco Brügger, Julia Piredda, Gian Franco Hilbert, Tom Cadic-Melchior, Andéol G. Beanato, Elena Park, Chang-Hyun Morishita, Takuya Wessel, Maximilian J. Schiavi, Simona Daducci, Alessandro Kober, Tobias Canales-Rodríguez, Erick J. Hummel, Friedhelm C. Thiran, Jean-Philippe |
author_sort | Fischi-Gomez, Elda |
collection | PubMed |
description | Quantitative magnetic resonance imaging (qMRI) can increase the specificity and sensitivity of conventional weighted MRI to underlying pathology by comparing meaningful physical or chemical parameters, measured in physical units, with normative values acquired in a healthy population. This study focuses on multi-echo T(2) relaxometry, a qMRI technique that probes the complex tissue microstructure by differentiating compartment-specific T(2) relaxation times. However, estimation methods are still limited by their sensitivity to the underlying noise. Moreover, estimating the model's parameters is challenging because the resulting inverse problem is ill-posed, requiring advanced numerical regularization techniques. As a result, the estimates from distinct regularization strategies are different. In this work, we aimed to investigate the variability and reproducibility of different techniques for estimating the transverse relaxation time of the intra- and extra-cellular space ([Formula: see text]) in gray (GM) and white matter (WM) tissue in a clinical setting, using a multi-site, multi-session, and multi-run T(2) relaxometry dataset. To this end, we evaluated three different techniques for estimating the T(2) spectra (two regularized non-negative least squares methods and a machine learning approach). Two independent analyses were performed to study the effect of using raw and denoised data. For both the GM and WM regions, and the raw and denoised data, our results suggest that the principal source of variance is the inter-subject variability, showing a higher coefficient of variation (CoV) than those estimated for the inter-site, inter-session, and inter-run, respectively. For all reconstruction methods studied, the CoV ranged between 0.32 and 1.64%. Interestingly, the inter-session variability was close to the inter-scanner variability with no statistical differences, suggesting that [Formula: see text] is a robust parameter that could be employed in multi-site neuroimaging studies. Furthermore, the three tested methods showed consistent results and similar intra-class correlation (ICC), with values superior to 0.7 for most regions. Results from raw data were slightly more reproducible than those from denoised data. The regularized non-negative least squares method based on the L-curve technique produced the best results, with ICC values ranging from 0.72 to 0.92. |
format | Online Article Text |
id | pubmed-10365099 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-103650992023-07-25 Variability and reproducibility of multi-echo T(2) relaxometry: Insights from multi-site, multi-session and multi-subject MRI acquisitions Fischi-Gomez, Elda Girard, Gabriel Koch, Philipp J. Yu, Thomas Pizzolato, Marco Brügger, Julia Piredda, Gian Franco Hilbert, Tom Cadic-Melchior, Andéol G. Beanato, Elena Park, Chang-Hyun Morishita, Takuya Wessel, Maximilian J. Schiavi, Simona Daducci, Alessandro Kober, Tobias Canales-Rodríguez, Erick J. Hummel, Friedhelm C. Thiran, Jean-Philippe Front Radiol Radiology Quantitative magnetic resonance imaging (qMRI) can increase the specificity and sensitivity of conventional weighted MRI to underlying pathology by comparing meaningful physical or chemical parameters, measured in physical units, with normative values acquired in a healthy population. This study focuses on multi-echo T(2) relaxometry, a qMRI technique that probes the complex tissue microstructure by differentiating compartment-specific T(2) relaxation times. However, estimation methods are still limited by their sensitivity to the underlying noise. Moreover, estimating the model's parameters is challenging because the resulting inverse problem is ill-posed, requiring advanced numerical regularization techniques. As a result, the estimates from distinct regularization strategies are different. In this work, we aimed to investigate the variability and reproducibility of different techniques for estimating the transverse relaxation time of the intra- and extra-cellular space ([Formula: see text]) in gray (GM) and white matter (WM) tissue in a clinical setting, using a multi-site, multi-session, and multi-run T(2) relaxometry dataset. To this end, we evaluated three different techniques for estimating the T(2) spectra (two regularized non-negative least squares methods and a machine learning approach). Two independent analyses were performed to study the effect of using raw and denoised data. For both the GM and WM regions, and the raw and denoised data, our results suggest that the principal source of variance is the inter-subject variability, showing a higher coefficient of variation (CoV) than those estimated for the inter-site, inter-session, and inter-run, respectively. For all reconstruction methods studied, the CoV ranged between 0.32 and 1.64%. Interestingly, the inter-session variability was close to the inter-scanner variability with no statistical differences, suggesting that [Formula: see text] is a robust parameter that could be employed in multi-site neuroimaging studies. Furthermore, the three tested methods showed consistent results and similar intra-class correlation (ICC), with values superior to 0.7 for most regions. Results from raw data were slightly more reproducible than those from denoised data. The regularized non-negative least squares method based on the L-curve technique produced the best results, with ICC values ranging from 0.72 to 0.92. Frontiers Media S.A. 2022-07-28 /pmc/articles/PMC10365099/ /pubmed/37492668 http://dx.doi.org/10.3389/fradi.2022.930666 Text en Copyright © 2022 Fischi-Gomez, Girard, Koch, Yu, Pizzolato, Brügger, Piredda, Hilbert, Cadic-Melchior, Beanato, Park, Morishita, Wessel, Schiavi, Daducci, Kober, Canales-Rodríguez, Hummel and Thiran. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Radiology Fischi-Gomez, Elda Girard, Gabriel Koch, Philipp J. Yu, Thomas Pizzolato, Marco Brügger, Julia Piredda, Gian Franco Hilbert, Tom Cadic-Melchior, Andéol G. Beanato, Elena Park, Chang-Hyun Morishita, Takuya Wessel, Maximilian J. Schiavi, Simona Daducci, Alessandro Kober, Tobias Canales-Rodríguez, Erick J. Hummel, Friedhelm C. Thiran, Jean-Philippe Variability and reproducibility of multi-echo T(2) relaxometry: Insights from multi-site, multi-session and multi-subject MRI acquisitions |
title | Variability and reproducibility of multi-echo T(2) relaxometry: Insights from multi-site, multi-session and multi-subject MRI acquisitions |
title_full | Variability and reproducibility of multi-echo T(2) relaxometry: Insights from multi-site, multi-session and multi-subject MRI acquisitions |
title_fullStr | Variability and reproducibility of multi-echo T(2) relaxometry: Insights from multi-site, multi-session and multi-subject MRI acquisitions |
title_full_unstemmed | Variability and reproducibility of multi-echo T(2) relaxometry: Insights from multi-site, multi-session and multi-subject MRI acquisitions |
title_short | Variability and reproducibility of multi-echo T(2) relaxometry: Insights from multi-site, multi-session and multi-subject MRI acquisitions |
title_sort | variability and reproducibility of multi-echo t(2) relaxometry: insights from multi-site, multi-session and multi-subject mri acquisitions |
topic | Radiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10365099/ https://www.ncbi.nlm.nih.gov/pubmed/37492668 http://dx.doi.org/10.3389/fradi.2022.930666 |
work_keys_str_mv | AT fischigomezelda variabilityandreproducibilityofmultiechot2relaxometryinsightsfrommultisitemultisessionandmultisubjectmriacquisitions AT girardgabriel variabilityandreproducibilityofmultiechot2relaxometryinsightsfrommultisitemultisessionandmultisubjectmriacquisitions AT kochphilippj variabilityandreproducibilityofmultiechot2relaxometryinsightsfrommultisitemultisessionandmultisubjectmriacquisitions AT yuthomas variabilityandreproducibilityofmultiechot2relaxometryinsightsfrommultisitemultisessionandmultisubjectmriacquisitions AT pizzolatomarco variabilityandreproducibilityofmultiechot2relaxometryinsightsfrommultisitemultisessionandmultisubjectmriacquisitions AT bruggerjulia variabilityandreproducibilityofmultiechot2relaxometryinsightsfrommultisitemultisessionandmultisubjectmriacquisitions AT pireddagianfranco variabilityandreproducibilityofmultiechot2relaxometryinsightsfrommultisitemultisessionandmultisubjectmriacquisitions AT hilberttom variabilityandreproducibilityofmultiechot2relaxometryinsightsfrommultisitemultisessionandmultisubjectmriacquisitions AT cadicmelchiorandeolg variabilityandreproducibilityofmultiechot2relaxometryinsightsfrommultisitemultisessionandmultisubjectmriacquisitions AT beanatoelena variabilityandreproducibilityofmultiechot2relaxometryinsightsfrommultisitemultisessionandmultisubjectmriacquisitions AT parkchanghyun variabilityandreproducibilityofmultiechot2relaxometryinsightsfrommultisitemultisessionandmultisubjectmriacquisitions AT morishitatakuya variabilityandreproducibilityofmultiechot2relaxometryinsightsfrommultisitemultisessionandmultisubjectmriacquisitions AT wesselmaximilianj variabilityandreproducibilityofmultiechot2relaxometryinsightsfrommultisitemultisessionandmultisubjectmriacquisitions AT schiavisimona variabilityandreproducibilityofmultiechot2relaxometryinsightsfrommultisitemultisessionandmultisubjectmriacquisitions AT daduccialessandro variabilityandreproducibilityofmultiechot2relaxometryinsightsfrommultisitemultisessionandmultisubjectmriacquisitions AT kobertobias variabilityandreproducibilityofmultiechot2relaxometryinsightsfrommultisitemultisessionandmultisubjectmriacquisitions AT canalesrodriguezerickj variabilityandreproducibilityofmultiechot2relaxometryinsightsfrommultisitemultisessionandmultisubjectmriacquisitions AT hummelfriedhelmc variabilityandreproducibilityofmultiechot2relaxometryinsightsfrommultisitemultisessionandmultisubjectmriacquisitions AT thiranjeanphilippe variabilityandreproducibilityofmultiechot2relaxometryinsightsfrommultisitemultisessionandmultisubjectmriacquisitions |