Sound insulation dataset of 30 wooden and 8 concrete floors tested in laboratory conditions
In a Finnish-Swedish consortium project, a large amount of sound insulation tests was conducted for several intermediate floors in laboratory conditions to serve various scientific research questions. The dataset contains 30 wooden and 8 concrete constructions which are commonly used between apartme...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10365936/ https://www.ncbi.nlm.nih.gov/pubmed/37492232 http://dx.doi.org/10.1016/j.dib.2023.109393 |
_version_ | 1785077060417355776 |
---|---|
author | Hongisto, Valtteri Alakoivu, Reijo Virtanen, Juho Hakala, Jarkko Saarinen, Pekka Laukka, Johann Linderholt, Andreas Olsson, Jörgen Jarnerö, Kirsi Keränen, Jukka |
author_facet | Hongisto, Valtteri Alakoivu, Reijo Virtanen, Juho Hakala, Jarkko Saarinen, Pekka Laukka, Johann Linderholt, Andreas Olsson, Jörgen Jarnerö, Kirsi Keränen, Jukka |
author_sort | Hongisto, Valtteri |
collection | PubMed |
description | In a Finnish-Swedish consortium project, a large amount of sound insulation tests was conducted for several intermediate floors in laboratory conditions to serve various scientific research questions. The dataset contains 30 wooden and 8 concrete constructions which are commonly used between apartments in multistorey buildings. Impact sound insulation was determined according to ISO 10140-3 standard using both tapping machine and rubber ball as standard sound sources. Airborne sound insulation was determined according to the ISO 10140-2 standard. The data are special since they have a broad frequency range: 20−5000 Hz. Data are reported in 1/3-octave frequency bands and the single-number values of ISO 717-1 and ISO 717-2 are also reported. Detailed construction drawings are available for all reported constructions. The data are highly valuable for research, education, and development purposes since all data were obtained in the same laboratory (Turku University of Applied Sciences, Turku, Finland), and all the constructions were built by the same installation team. |
format | Online Article Text |
id | pubmed-10365936 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-103659362023-07-25 Sound insulation dataset of 30 wooden and 8 concrete floors tested in laboratory conditions Hongisto, Valtteri Alakoivu, Reijo Virtanen, Juho Hakala, Jarkko Saarinen, Pekka Laukka, Johann Linderholt, Andreas Olsson, Jörgen Jarnerö, Kirsi Keränen, Jukka Data Brief Data Article In a Finnish-Swedish consortium project, a large amount of sound insulation tests was conducted for several intermediate floors in laboratory conditions to serve various scientific research questions. The dataset contains 30 wooden and 8 concrete constructions which are commonly used between apartments in multistorey buildings. Impact sound insulation was determined according to ISO 10140-3 standard using both tapping machine and rubber ball as standard sound sources. Airborne sound insulation was determined according to the ISO 10140-2 standard. The data are special since they have a broad frequency range: 20−5000 Hz. Data are reported in 1/3-octave frequency bands and the single-number values of ISO 717-1 and ISO 717-2 are also reported. Detailed construction drawings are available for all reported constructions. The data are highly valuable for research, education, and development purposes since all data were obtained in the same laboratory (Turku University of Applied Sciences, Turku, Finland), and all the constructions were built by the same installation team. Elsevier 2023-07-09 /pmc/articles/PMC10365936/ /pubmed/37492232 http://dx.doi.org/10.1016/j.dib.2023.109393 Text en © 2023 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Data Article Hongisto, Valtteri Alakoivu, Reijo Virtanen, Juho Hakala, Jarkko Saarinen, Pekka Laukka, Johann Linderholt, Andreas Olsson, Jörgen Jarnerö, Kirsi Keränen, Jukka Sound insulation dataset of 30 wooden and 8 concrete floors tested in laboratory conditions |
title | Sound insulation dataset of 30 wooden and 8 concrete floors tested in laboratory conditions |
title_full | Sound insulation dataset of 30 wooden and 8 concrete floors tested in laboratory conditions |
title_fullStr | Sound insulation dataset of 30 wooden and 8 concrete floors tested in laboratory conditions |
title_full_unstemmed | Sound insulation dataset of 30 wooden and 8 concrete floors tested in laboratory conditions |
title_short | Sound insulation dataset of 30 wooden and 8 concrete floors tested in laboratory conditions |
title_sort | sound insulation dataset of 30 wooden and 8 concrete floors tested in laboratory conditions |
topic | Data Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10365936/ https://www.ncbi.nlm.nih.gov/pubmed/37492232 http://dx.doi.org/10.1016/j.dib.2023.109393 |
work_keys_str_mv | AT hongistovaltteri soundinsulationdatasetof30woodenand8concretefloorstestedinlaboratoryconditions AT alakoivureijo soundinsulationdatasetof30woodenand8concretefloorstestedinlaboratoryconditions AT virtanenjuho soundinsulationdatasetof30woodenand8concretefloorstestedinlaboratoryconditions AT hakalajarkko soundinsulationdatasetof30woodenand8concretefloorstestedinlaboratoryconditions AT saarinenpekka soundinsulationdatasetof30woodenand8concretefloorstestedinlaboratoryconditions AT laukkajohann soundinsulationdatasetof30woodenand8concretefloorstestedinlaboratoryconditions AT linderholtandreas soundinsulationdatasetof30woodenand8concretefloorstestedinlaboratoryconditions AT olssonjorgen soundinsulationdatasetof30woodenand8concretefloorstestedinlaboratoryconditions AT jarnerokirsi soundinsulationdatasetof30woodenand8concretefloorstestedinlaboratoryconditions AT keranenjukka soundinsulationdatasetof30woodenand8concretefloorstestedinlaboratoryconditions |