Cargando…
Revision Distal Femoral Replacement Using Custom-made Stem and Cone to Augment Proximal Fixation
Achieving bone fixation during megaprosthesis revision presents a formidable challenge in view of the substantial bone loss. We report treatment of a failed revision distal femoral replacement in an active 36-year-old male mechanic remotely treated for osteosarcoma. A custom stem and cone were manuf...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10365986/ https://www.ncbi.nlm.nih.gov/pubmed/37497550 http://dx.doi.org/10.1016/j.artd.2023.101158 |
_version_ | 1785077073392435200 |
---|---|
author | AlFayyadh, Faisal Nooh, Anas Tanzer, Michael Turcotte, Robert Hart, Adam |
author_facet | AlFayyadh, Faisal Nooh, Anas Tanzer, Michael Turcotte, Robert Hart, Adam |
author_sort | AlFayyadh, Faisal |
collection | PubMed |
description | Achieving bone fixation during megaprosthesis revision presents a formidable challenge in view of the substantial bone loss. We report treatment of a failed revision distal femoral replacement in an active 36-year-old male mechanic remotely treated for osteosarcoma. A custom stem and cone were manufactured to augment fixation and preserve bone stock within a short segment of the remaining proximal femur. The patient returned to regular function without the need for assistive devices. Follow-up imaging demonstrated stable implant fixation at 1-year follow-up. While cones and sleeves have vastly improved fixation in revision knee arthroplasty, a custom-made cone for the proximal femur was used to augment fixation of a revision megaprosthesis and obviate the use of a total femoral replacement. |
format | Online Article Text |
id | pubmed-10365986 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-103659862023-07-26 Revision Distal Femoral Replacement Using Custom-made Stem and Cone to Augment Proximal Fixation AlFayyadh, Faisal Nooh, Anas Tanzer, Michael Turcotte, Robert Hart, Adam Arthroplast Today Case Report Achieving bone fixation during megaprosthesis revision presents a formidable challenge in view of the substantial bone loss. We report treatment of a failed revision distal femoral replacement in an active 36-year-old male mechanic remotely treated for osteosarcoma. A custom stem and cone were manufactured to augment fixation and preserve bone stock within a short segment of the remaining proximal femur. The patient returned to regular function without the need for assistive devices. Follow-up imaging demonstrated stable implant fixation at 1-year follow-up. While cones and sleeves have vastly improved fixation in revision knee arthroplasty, a custom-made cone for the proximal femur was used to augment fixation of a revision megaprosthesis and obviate the use of a total femoral replacement. Elsevier 2023-07-12 /pmc/articles/PMC10365986/ /pubmed/37497550 http://dx.doi.org/10.1016/j.artd.2023.101158 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report AlFayyadh, Faisal Nooh, Anas Tanzer, Michael Turcotte, Robert Hart, Adam Revision Distal Femoral Replacement Using Custom-made Stem and Cone to Augment Proximal Fixation |
title | Revision Distal Femoral Replacement Using Custom-made Stem and Cone to Augment Proximal Fixation |
title_full | Revision Distal Femoral Replacement Using Custom-made Stem and Cone to Augment Proximal Fixation |
title_fullStr | Revision Distal Femoral Replacement Using Custom-made Stem and Cone to Augment Proximal Fixation |
title_full_unstemmed | Revision Distal Femoral Replacement Using Custom-made Stem and Cone to Augment Proximal Fixation |
title_short | Revision Distal Femoral Replacement Using Custom-made Stem and Cone to Augment Proximal Fixation |
title_sort | revision distal femoral replacement using custom-made stem and cone to augment proximal fixation |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10365986/ https://www.ncbi.nlm.nih.gov/pubmed/37497550 http://dx.doi.org/10.1016/j.artd.2023.101158 |
work_keys_str_mv | AT alfayyadhfaisal revisiondistalfemoralreplacementusingcustommadestemandconetoaugmentproximalfixation AT noohanas revisiondistalfemoralreplacementusingcustommadestemandconetoaugmentproximalfixation AT tanzermichael revisiondistalfemoralreplacementusingcustommadestemandconetoaugmentproximalfixation AT turcotterobert revisiondistalfemoralreplacementusingcustommadestemandconetoaugmentproximalfixation AT hartadam revisiondistalfemoralreplacementusingcustommadestemandconetoaugmentproximalfixation |