An extendable optical fibre probe survey meter for naturally occurring radioactive material (NORM) and other weak emitters

We have developed a radioluminescence-based survey meter for use in industries in which there is involvement in naturally occurring radioactive material (NORM), also in support of those needing to detect other weak emitters of radiation. The functionality of the system confronts particular shortcomi...

Descripción completa

Detalles Bibliográficos
Autores principales: Zubair, H. T., Bradley, D. A., Khairina, M. D., Oresegun, Adebiyi, Basaif, A., Othman, J., Rifiat, R., Hamidi, F., Rahman, L., Ezzadeen, A., Ibrahim, S. A., Mansor, S., Alkhorayef, M., Abdul-Rashid, H. A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10366106/
https://www.ncbi.nlm.nih.gov/pubmed/37488183
http://dx.doi.org/10.1038/s41598-023-39180-9
_version_ 1785077098177626112
author Zubair, H. T.
Bradley, D. A.
Khairina, M. D.
Oresegun, Adebiyi
Basaif, A.
Othman, J.
Rifiat, R.
Hamidi, F.
Rahman, L.
Ezzadeen, A.
Ibrahim, S. A.
Mansor, S.
Alkhorayef, M.
Abdul-Rashid, H. A.
author_facet Zubair, H. T.
Bradley, D. A.
Khairina, M. D.
Oresegun, Adebiyi
Basaif, A.
Othman, J.
Rifiat, R.
Hamidi, F.
Rahman, L.
Ezzadeen, A.
Ibrahim, S. A.
Mansor, S.
Alkhorayef, M.
Abdul-Rashid, H. A.
author_sort Zubair, H. T.
collection PubMed
description We have developed a radioluminescence-based survey meter for use in industries in which there is involvement in naturally occurring radioactive material (NORM), also in support of those needing to detect other weak emitters of radiation. The functionality of the system confronts particular shortcomings of the handheld survey meters that are currently being made use of. The device couples a LYSO:Ce scintillator with a photodetector via a polymer optical fibre waveguide, allowing for "intrinsically safe" inspection within pipework, separators, valves and other such component pieces. The small-diameter optical fibre probe is electrically passive, immune to electromagnetic interference, and chemically inert. The readout circuit is entirely incorporated within a handheld casing housing a silicon photomultiplier (SiPM) detection circuit and a microprocessor circuit connected to an LCD display. A 15 m long flexible PMMA optical fibre waveguide is butt coupled to an ABS plastic probe that retains the LYSO:Ce scintillator. Initial tests have included the use of lab-based mixed gamma-ray sources, measurements being made in concert with a reference conventional GM survey-meter. Characterization, via NORM sources at a decontamination facility, has shown useful sensitivity, covering the dose-rate range 0.10- to 28 µSv h(−1) (R-squared 0.966), extending to 80 µSv/h as demonstrated in use of a Cs-137 source. The system is shown to provide an effective tool for detection of radioactivity within hard to access locations, in particular for sources emitting at low radiation levels, down to values that approach background.
format Online
Article
Text
id pubmed-10366106
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-103661062023-07-26 An extendable optical fibre probe survey meter for naturally occurring radioactive material (NORM) and other weak emitters Zubair, H. T. Bradley, D. A. Khairina, M. D. Oresegun, Adebiyi Basaif, A. Othman, J. Rifiat, R. Hamidi, F. Rahman, L. Ezzadeen, A. Ibrahim, S. A. Mansor, S. Alkhorayef, M. Abdul-Rashid, H. A. Sci Rep Article We have developed a radioluminescence-based survey meter for use in industries in which there is involvement in naturally occurring radioactive material (NORM), also in support of those needing to detect other weak emitters of radiation. The functionality of the system confronts particular shortcomings of the handheld survey meters that are currently being made use of. The device couples a LYSO:Ce scintillator with a photodetector via a polymer optical fibre waveguide, allowing for "intrinsically safe" inspection within pipework, separators, valves and other such component pieces. The small-diameter optical fibre probe is electrically passive, immune to electromagnetic interference, and chemically inert. The readout circuit is entirely incorporated within a handheld casing housing a silicon photomultiplier (SiPM) detection circuit and a microprocessor circuit connected to an LCD display. A 15 m long flexible PMMA optical fibre waveguide is butt coupled to an ABS plastic probe that retains the LYSO:Ce scintillator. Initial tests have included the use of lab-based mixed gamma-ray sources, measurements being made in concert with a reference conventional GM survey-meter. Characterization, via NORM sources at a decontamination facility, has shown useful sensitivity, covering the dose-rate range 0.10- to 28 µSv h(−1) (R-squared 0.966), extending to 80 µSv/h as demonstrated in use of a Cs-137 source. The system is shown to provide an effective tool for detection of radioactivity within hard to access locations, in particular for sources emitting at low radiation levels, down to values that approach background. Nature Publishing Group UK 2023-07-24 /pmc/articles/PMC10366106/ /pubmed/37488183 http://dx.doi.org/10.1038/s41598-023-39180-9 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Zubair, H. T.
Bradley, D. A.
Khairina, M. D.
Oresegun, Adebiyi
Basaif, A.
Othman, J.
Rifiat, R.
Hamidi, F.
Rahman, L.
Ezzadeen, A.
Ibrahim, S. A.
Mansor, S.
Alkhorayef, M.
Abdul-Rashid, H. A.
An extendable optical fibre probe survey meter for naturally occurring radioactive material (NORM) and other weak emitters
title An extendable optical fibre probe survey meter for naturally occurring radioactive material (NORM) and other weak emitters
title_full An extendable optical fibre probe survey meter for naturally occurring radioactive material (NORM) and other weak emitters
title_fullStr An extendable optical fibre probe survey meter for naturally occurring radioactive material (NORM) and other weak emitters
title_full_unstemmed An extendable optical fibre probe survey meter for naturally occurring radioactive material (NORM) and other weak emitters
title_short An extendable optical fibre probe survey meter for naturally occurring radioactive material (NORM) and other weak emitters
title_sort extendable optical fibre probe survey meter for naturally occurring radioactive material (norm) and other weak emitters
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10366106/
https://www.ncbi.nlm.nih.gov/pubmed/37488183
http://dx.doi.org/10.1038/s41598-023-39180-9
work_keys_str_mv AT zubairht anextendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT bradleyda anextendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT khairinamd anextendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT oresegunadebiyi anextendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT basaifa anextendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT othmanj anextendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT rifiatr anextendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT hamidif anextendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT rahmanl anextendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT ezzadeena anextendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT ibrahimsa anextendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT mansors anextendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT alkhorayefm anextendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT abdulrashidha anextendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT zubairht extendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT bradleyda extendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT khairinamd extendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT oresegunadebiyi extendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT basaifa extendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT othmanj extendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT rifiatr extendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT hamidif extendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT rahmanl extendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT ezzadeena extendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT ibrahimsa extendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT mansors extendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT alkhorayefm extendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters
AT abdulrashidha extendableopticalfibreprobesurveymeterfornaturallyoccurringradioactivematerialnormandotherweakemitters