Cargando…
Green and white MEKC for determination of different anti-diabetic binary mixtures and their triple-combo pill
The work introduces green and white sustainable micellar electrokinetic chromatography (MEKC) procedure that could analyze therapeutically related drugs, empagliflozin (EMP), linagliptin (LIN) and metformin (MET) which are antidiabetic drugs with different mechanism of action, in their different pha...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10367405/ https://www.ncbi.nlm.nih.gov/pubmed/37488616 http://dx.doi.org/10.1186/s13065-023-00997-0 |
Sumario: | The work introduces green and white sustainable micellar electrokinetic chromatography (MEKC) procedure that could analyze therapeutically related drugs, empagliflozin (EMP), linagliptin (LIN) and metformin (MET) which are antidiabetic drugs with different mechanism of action, in their different pharmaceutical combinations. The method not only comply with the green analytical concepts, but also it is in line with sustainable analytical concepts as it is economic by applying the same operating conditions to analyze different pharmaceuticals in quality control (QC) labs which is a crucial step in QC labs and research centers to save time, effort, and money. Moreover, the method functionality regarding its scope with its achieved levels of accuracy, precision, low detection, and quantitation limits is tested using white assessment tool and compared with reported methods. The proposed MEKC coupled with a diode array detector (DAD) has been developed and validated for micro estimation of EMP and LIN in their low critical concentrations with MET in a ratio of (EMP: MET, 1:40) and (LIN: MET, 1:200). Separation was achieved within 6 min using fused silica capillary (40 cm × 50 µm id) using 20 mM Tris buffer (pH 10) in presence of 50 mM sodium dodecyl sulphate and 10% v/v methanol. The concentration ranges of the studied anti-diabetic drugs were 10–500, 10–100 and 2.5–100 µg. mL(−1) for MET, EMP and LIN, respectively. The developed method is the first MEKC for concurrent determination of EMP, LIN and MET with high separation efficiency, low solvent consumption and regard as an easy green and white analytical tool. Moreover, Greenness and whiteness assessment were done via the most widely used Analytical Eco-Scale, the innovative AGREE tool and the RGB 12 algorithm. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13065-023-00997-0. |
---|