Cargando…
End Sigmoid Colostomy Reconstruction Using Purse-string Subcutaneous Suture via Extraperitoneal Route at the Site of a Previous Transperitoneal Loop Stoma
We previously experienced two cases of end sigmoid colostomy reconstruction via the extraperitoneal route at the same site as the transperitoneal loop stoma. For an anterior rectus fascia, the transperitoneal route used closed intraperitoneal interrupted sutures and continuous sutures with barbed su...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Japan Society of Coloproctology
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10368428/ https://www.ncbi.nlm.nih.gov/pubmed/37496572 http://dx.doi.org/10.23922/jarc.2023-005 |
_version_ | 1785077503949275136 |
---|---|
author | Yoshimatsu, Kazuhiko Tanaka, Hironori Ito, Yoshitomo Kinoshita, Seiya Higashida, Masaharu Okada, Toshimasa Endo, Shuji Fujiwara, Yoshinori Ueno, Tomio |
author_facet | Yoshimatsu, Kazuhiko Tanaka, Hironori Ito, Yoshitomo Kinoshita, Seiya Higashida, Masaharu Okada, Toshimasa Endo, Shuji Fujiwara, Yoshinori Ueno, Tomio |
author_sort | Yoshimatsu, Kazuhiko |
collection | PubMed |
description | We previously experienced two cases of end sigmoid colostomy reconstruction via the extraperitoneal route at the same site as the transperitoneal loop stoma. For an anterior rectus fascia, the transperitoneal route used closed intraperitoneal interrupted sutures and continuous sutures with barbed sutures. A new extraperitoneal route was established through the sutured anterior rectus sheath. Before reconstructing the end stoma, a subcutaneous purse-string with monofilament absorbable sutures tied to create an approximately 2.5 cm diameter was used. There were no early complications associated with the stoma. One year after surgery, a parastomal hernia was not defined. Using the presented technique, two cases were successfully recreated extraperitoneally at the same site's end stoma. |
format | Online Article Text |
id | pubmed-10368428 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | The Japan Society of Coloproctology |
record_format | MEDLINE/PubMed |
spelling | pubmed-103684282023-07-26 End Sigmoid Colostomy Reconstruction Using Purse-string Subcutaneous Suture via Extraperitoneal Route at the Site of a Previous Transperitoneal Loop Stoma Yoshimatsu, Kazuhiko Tanaka, Hironori Ito, Yoshitomo Kinoshita, Seiya Higashida, Masaharu Okada, Toshimasa Endo, Shuji Fujiwara, Yoshinori Ueno, Tomio J Anus Rectum Colon How I Do It We previously experienced two cases of end sigmoid colostomy reconstruction via the extraperitoneal route at the same site as the transperitoneal loop stoma. For an anterior rectus fascia, the transperitoneal route used closed intraperitoneal interrupted sutures and continuous sutures with barbed sutures. A new extraperitoneal route was established through the sutured anterior rectus sheath. Before reconstructing the end stoma, a subcutaneous purse-string with monofilament absorbable sutures tied to create an approximately 2.5 cm diameter was used. There were no early complications associated with the stoma. One year after surgery, a parastomal hernia was not defined. Using the presented technique, two cases were successfully recreated extraperitoneally at the same site's end stoma. The Japan Society of Coloproctology 2023-07-25 /pmc/articles/PMC10368428/ /pubmed/37496572 http://dx.doi.org/10.23922/jarc.2023-005 Text en Copyright © 2023 The Japan Society of Coloproctology https://creativecommons.org/licenses/by-nc-nd/4.0/Journal of the Anus, Rectum and Colon is an Open Access journal distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view the details of this license, please visit (https://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | How I Do It Yoshimatsu, Kazuhiko Tanaka, Hironori Ito, Yoshitomo Kinoshita, Seiya Higashida, Masaharu Okada, Toshimasa Endo, Shuji Fujiwara, Yoshinori Ueno, Tomio End Sigmoid Colostomy Reconstruction Using Purse-string Subcutaneous Suture via Extraperitoneal Route at the Site of a Previous Transperitoneal Loop Stoma |
title | End Sigmoid Colostomy Reconstruction Using Purse-string Subcutaneous Suture via Extraperitoneal Route at the Site of a Previous Transperitoneal Loop Stoma |
title_full | End Sigmoid Colostomy Reconstruction Using Purse-string Subcutaneous Suture via Extraperitoneal Route at the Site of a Previous Transperitoneal Loop Stoma |
title_fullStr | End Sigmoid Colostomy Reconstruction Using Purse-string Subcutaneous Suture via Extraperitoneal Route at the Site of a Previous Transperitoneal Loop Stoma |
title_full_unstemmed | End Sigmoid Colostomy Reconstruction Using Purse-string Subcutaneous Suture via Extraperitoneal Route at the Site of a Previous Transperitoneal Loop Stoma |
title_short | End Sigmoid Colostomy Reconstruction Using Purse-string Subcutaneous Suture via Extraperitoneal Route at the Site of a Previous Transperitoneal Loop Stoma |
title_sort | end sigmoid colostomy reconstruction using purse-string subcutaneous suture via extraperitoneal route at the site of a previous transperitoneal loop stoma |
topic | How I Do It |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10368428/ https://www.ncbi.nlm.nih.gov/pubmed/37496572 http://dx.doi.org/10.23922/jarc.2023-005 |
work_keys_str_mv | AT yoshimatsukazuhiko endsigmoidcolostomyreconstructionusingpursestringsubcutaneoussutureviaextraperitonealrouteatthesiteofaprevioustransperitonealloopstoma AT tanakahironori endsigmoidcolostomyreconstructionusingpursestringsubcutaneoussutureviaextraperitonealrouteatthesiteofaprevioustransperitonealloopstoma AT itoyoshitomo endsigmoidcolostomyreconstructionusingpursestringsubcutaneoussutureviaextraperitonealrouteatthesiteofaprevioustransperitonealloopstoma AT kinoshitaseiya endsigmoidcolostomyreconstructionusingpursestringsubcutaneoussutureviaextraperitonealrouteatthesiteofaprevioustransperitonealloopstoma AT higashidamasaharu endsigmoidcolostomyreconstructionusingpursestringsubcutaneoussutureviaextraperitonealrouteatthesiteofaprevioustransperitonealloopstoma AT okadatoshimasa endsigmoidcolostomyreconstructionusingpursestringsubcutaneoussutureviaextraperitonealrouteatthesiteofaprevioustransperitonealloopstoma AT endoshuji endsigmoidcolostomyreconstructionusingpursestringsubcutaneoussutureviaextraperitonealrouteatthesiteofaprevioustransperitonealloopstoma AT fujiwarayoshinori endsigmoidcolostomyreconstructionusingpursestringsubcutaneoussutureviaextraperitonealrouteatthesiteofaprevioustransperitonealloopstoma AT uenotomio endsigmoidcolostomyreconstructionusingpursestringsubcutaneoussutureviaextraperitonealrouteatthesiteofaprevioustransperitonealloopstoma |