Cargando…

End Sigmoid Colostomy Reconstruction Using Purse-string Subcutaneous Suture via Extraperitoneal Route at the Site of a Previous Transperitoneal Loop Stoma

We previously experienced two cases of end sigmoid colostomy reconstruction via the extraperitoneal route at the same site as the transperitoneal loop stoma. For an anterior rectus fascia, the transperitoneal route used closed intraperitoneal interrupted sutures and continuous sutures with barbed su...

Descripción completa

Detalles Bibliográficos
Autores principales: Yoshimatsu, Kazuhiko, Tanaka, Hironori, Ito, Yoshitomo, Kinoshita, Seiya, Higashida, Masaharu, Okada, Toshimasa, Endo, Shuji, Fujiwara, Yoshinori, Ueno, Tomio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Japan Society of Coloproctology 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10368428/
https://www.ncbi.nlm.nih.gov/pubmed/37496572
http://dx.doi.org/10.23922/jarc.2023-005
_version_ 1785077503949275136
author Yoshimatsu, Kazuhiko
Tanaka, Hironori
Ito, Yoshitomo
Kinoshita, Seiya
Higashida, Masaharu
Okada, Toshimasa
Endo, Shuji
Fujiwara, Yoshinori
Ueno, Tomio
author_facet Yoshimatsu, Kazuhiko
Tanaka, Hironori
Ito, Yoshitomo
Kinoshita, Seiya
Higashida, Masaharu
Okada, Toshimasa
Endo, Shuji
Fujiwara, Yoshinori
Ueno, Tomio
author_sort Yoshimatsu, Kazuhiko
collection PubMed
description We previously experienced two cases of end sigmoid colostomy reconstruction via the extraperitoneal route at the same site as the transperitoneal loop stoma. For an anterior rectus fascia, the transperitoneal route used closed intraperitoneal interrupted sutures and continuous sutures with barbed sutures. A new extraperitoneal route was established through the sutured anterior rectus sheath. Before reconstructing the end stoma, a subcutaneous purse-string with monofilament absorbable sutures tied to create an approximately 2.5 cm diameter was used. There were no early complications associated with the stoma. One year after surgery, a parastomal hernia was not defined. Using the presented technique, two cases were successfully recreated extraperitoneally at the same site's end stoma.
format Online
Article
Text
id pubmed-10368428
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher The Japan Society of Coloproctology
record_format MEDLINE/PubMed
spelling pubmed-103684282023-07-26 End Sigmoid Colostomy Reconstruction Using Purse-string Subcutaneous Suture via Extraperitoneal Route at the Site of a Previous Transperitoneal Loop Stoma Yoshimatsu, Kazuhiko Tanaka, Hironori Ito, Yoshitomo Kinoshita, Seiya Higashida, Masaharu Okada, Toshimasa Endo, Shuji Fujiwara, Yoshinori Ueno, Tomio J Anus Rectum Colon How I Do It We previously experienced two cases of end sigmoid colostomy reconstruction via the extraperitoneal route at the same site as the transperitoneal loop stoma. For an anterior rectus fascia, the transperitoneal route used closed intraperitoneal interrupted sutures and continuous sutures with barbed sutures. A new extraperitoneal route was established through the sutured anterior rectus sheath. Before reconstructing the end stoma, a subcutaneous purse-string with monofilament absorbable sutures tied to create an approximately 2.5 cm diameter was used. There were no early complications associated with the stoma. One year after surgery, a parastomal hernia was not defined. Using the presented technique, two cases were successfully recreated extraperitoneally at the same site's end stoma. The Japan Society of Coloproctology 2023-07-25 /pmc/articles/PMC10368428/ /pubmed/37496572 http://dx.doi.org/10.23922/jarc.2023-005 Text en Copyright © 2023 The Japan Society of Coloproctology https://creativecommons.org/licenses/by-nc-nd/4.0/Journal of the Anus, Rectum and Colon is an Open Access journal distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view the details of this license, please visit (https://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle How I Do It
Yoshimatsu, Kazuhiko
Tanaka, Hironori
Ito, Yoshitomo
Kinoshita, Seiya
Higashida, Masaharu
Okada, Toshimasa
Endo, Shuji
Fujiwara, Yoshinori
Ueno, Tomio
End Sigmoid Colostomy Reconstruction Using Purse-string Subcutaneous Suture via Extraperitoneal Route at the Site of a Previous Transperitoneal Loop Stoma
title End Sigmoid Colostomy Reconstruction Using Purse-string Subcutaneous Suture via Extraperitoneal Route at the Site of a Previous Transperitoneal Loop Stoma
title_full End Sigmoid Colostomy Reconstruction Using Purse-string Subcutaneous Suture via Extraperitoneal Route at the Site of a Previous Transperitoneal Loop Stoma
title_fullStr End Sigmoid Colostomy Reconstruction Using Purse-string Subcutaneous Suture via Extraperitoneal Route at the Site of a Previous Transperitoneal Loop Stoma
title_full_unstemmed End Sigmoid Colostomy Reconstruction Using Purse-string Subcutaneous Suture via Extraperitoneal Route at the Site of a Previous Transperitoneal Loop Stoma
title_short End Sigmoid Colostomy Reconstruction Using Purse-string Subcutaneous Suture via Extraperitoneal Route at the Site of a Previous Transperitoneal Loop Stoma
title_sort end sigmoid colostomy reconstruction using purse-string subcutaneous suture via extraperitoneal route at the site of a previous transperitoneal loop stoma
topic How I Do It
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10368428/
https://www.ncbi.nlm.nih.gov/pubmed/37496572
http://dx.doi.org/10.23922/jarc.2023-005
work_keys_str_mv AT yoshimatsukazuhiko endsigmoidcolostomyreconstructionusingpursestringsubcutaneoussutureviaextraperitonealrouteatthesiteofaprevioustransperitonealloopstoma
AT tanakahironori endsigmoidcolostomyreconstructionusingpursestringsubcutaneoussutureviaextraperitonealrouteatthesiteofaprevioustransperitonealloopstoma
AT itoyoshitomo endsigmoidcolostomyreconstructionusingpursestringsubcutaneoussutureviaextraperitonealrouteatthesiteofaprevioustransperitonealloopstoma
AT kinoshitaseiya endsigmoidcolostomyreconstructionusingpursestringsubcutaneoussutureviaextraperitonealrouteatthesiteofaprevioustransperitonealloopstoma
AT higashidamasaharu endsigmoidcolostomyreconstructionusingpursestringsubcutaneoussutureviaextraperitonealrouteatthesiteofaprevioustransperitonealloopstoma
AT okadatoshimasa endsigmoidcolostomyreconstructionusingpursestringsubcutaneoussutureviaextraperitonealrouteatthesiteofaprevioustransperitonealloopstoma
AT endoshuji endsigmoidcolostomyreconstructionusingpursestringsubcutaneoussutureviaextraperitonealrouteatthesiteofaprevioustransperitonealloopstoma
AT fujiwarayoshinori endsigmoidcolostomyreconstructionusingpursestringsubcutaneoussutureviaextraperitonealrouteatthesiteofaprevioustransperitonealloopstoma
AT uenotomio endsigmoidcolostomyreconstructionusingpursestringsubcutaneoussutureviaextraperitonealrouteatthesiteofaprevioustransperitonealloopstoma