Cargando…
Usefulness of 3D T1-Turbo Spin Echo Imaging for the Evaluation of Intracranial Stent Placement
OBJECTIVE: Evaluation of intracranial stent placement by MRI suffers the problems of signal artifacts during time-of-flight MRA (TOF-MRA). Therefore, angiographic examination is required for detailed intravascular assessment of the stent placement site. Recently, 3D T1-turbo spin echo (3D-TSE) has b...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Japanese Society for Neuroendovascular Therapy
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10370516/ https://www.ncbi.nlm.nih.gov/pubmed/37501886 http://dx.doi.org/10.5797/jnet.oa.2022-0039 |
_version_ | 1785077950086905856 |
---|---|
author | Mizuno, Hiroyuki Aihara, Masanori Sato, Koji Negishi, Chikashi Sasaguchi, Nobuo Kurihara, Hideyuki Yoshimoto, Yuhei |
author_facet | Mizuno, Hiroyuki Aihara, Masanori Sato, Koji Negishi, Chikashi Sasaguchi, Nobuo Kurihara, Hideyuki Yoshimoto, Yuhei |
author_sort | Mizuno, Hiroyuki |
collection | PubMed |
description | OBJECTIVE: Evaluation of intracranial stent placement by MRI suffers the problems of signal artifacts during time-of-flight MRA (TOF-MRA). Therefore, angiographic examination is required for detailed intravascular assessment of the stent placement site. Recently, 3D T1-turbo spin echo (3D-TSE) has been developed for evaluation of carotid artery stent placement. We investigated the use of the 3D-TSE imaging method for the evaluation of intracranial vascular stent placement. METHODS: The subjects consisted of nine patients who underwent intracranial vascular stent placement between April 2015 and December 2019. Postoperatively, the lumens of the placed stents were measured by TOF-MRA, DSA, and 3D-TSE imaging. Analysis was performed by type of stent and placement site. RESULTS: The stents used were Neuroform Atlas (3 patients), LVIS (3 patients), LVIS Jr (2 patients), and Integrity (1 patient). TOF-MRA of the stent placement site showed defects in the image or poor visualization in all nine patients, whereas 3D-TSE imaging visualized the lumen at the stent indwelling site in all patients. The blood vessel diameter measured by the DSA and 3D-TSE imaging exhibited positive correlations regardless of the stent type and placement site. CONCLUSION: 3D-TSE imaging allows visualization of the lumen of the site of an intracranial vascular stent, regardless of the type of stent or the vessel. Thus, this method may be useful for evaluating the vascular lumen of a lesion. |
format | Online Article Text |
id | pubmed-10370516 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | The Japanese Society for Neuroendovascular Therapy |
record_format | MEDLINE/PubMed |
spelling | pubmed-103705162023-07-27 Usefulness of 3D T1-Turbo Spin Echo Imaging for the Evaluation of Intracranial Stent Placement Mizuno, Hiroyuki Aihara, Masanori Sato, Koji Negishi, Chikashi Sasaguchi, Nobuo Kurihara, Hideyuki Yoshimoto, Yuhei J Neuroendovasc Ther Original Article OBJECTIVE: Evaluation of intracranial stent placement by MRI suffers the problems of signal artifacts during time-of-flight MRA (TOF-MRA). Therefore, angiographic examination is required for detailed intravascular assessment of the stent placement site. Recently, 3D T1-turbo spin echo (3D-TSE) has been developed for evaluation of carotid artery stent placement. We investigated the use of the 3D-TSE imaging method for the evaluation of intracranial vascular stent placement. METHODS: The subjects consisted of nine patients who underwent intracranial vascular stent placement between April 2015 and December 2019. Postoperatively, the lumens of the placed stents were measured by TOF-MRA, DSA, and 3D-TSE imaging. Analysis was performed by type of stent and placement site. RESULTS: The stents used were Neuroform Atlas (3 patients), LVIS (3 patients), LVIS Jr (2 patients), and Integrity (1 patient). TOF-MRA of the stent placement site showed defects in the image or poor visualization in all nine patients, whereas 3D-TSE imaging visualized the lumen at the stent indwelling site in all patients. The blood vessel diameter measured by the DSA and 3D-TSE imaging exhibited positive correlations regardless of the stent type and placement site. CONCLUSION: 3D-TSE imaging allows visualization of the lumen of the site of an intracranial vascular stent, regardless of the type of stent or the vessel. Thus, this method may be useful for evaluating the vascular lumen of a lesion. The Japanese Society for Neuroendovascular Therapy 2022-10-14 2023 /pmc/articles/PMC10370516/ /pubmed/37501886 http://dx.doi.org/10.5797/jnet.oa.2022-0039 Text en ©2023 The Japanese Society for Neuroendovascular Therapy https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives International License (https://creativecommons.org/licenses/by-nc-nd/4.0/) |
spellingShingle | Original Article Mizuno, Hiroyuki Aihara, Masanori Sato, Koji Negishi, Chikashi Sasaguchi, Nobuo Kurihara, Hideyuki Yoshimoto, Yuhei Usefulness of 3D T1-Turbo Spin Echo Imaging for the Evaluation of Intracranial Stent Placement |
title | Usefulness of 3D T1-Turbo Spin Echo Imaging for the Evaluation of Intracranial Stent Placement |
title_full | Usefulness of 3D T1-Turbo Spin Echo Imaging for the Evaluation of Intracranial Stent Placement |
title_fullStr | Usefulness of 3D T1-Turbo Spin Echo Imaging for the Evaluation of Intracranial Stent Placement |
title_full_unstemmed | Usefulness of 3D T1-Turbo Spin Echo Imaging for the Evaluation of Intracranial Stent Placement |
title_short | Usefulness of 3D T1-Turbo Spin Echo Imaging for the Evaluation of Intracranial Stent Placement |
title_sort | usefulness of 3d t1-turbo spin echo imaging for the evaluation of intracranial stent placement |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10370516/ https://www.ncbi.nlm.nih.gov/pubmed/37501886 http://dx.doi.org/10.5797/jnet.oa.2022-0039 |
work_keys_str_mv | AT mizunohiroyuki usefulnessof3dt1turbospinechoimagingfortheevaluationofintracranialstentplacement AT aiharamasanori usefulnessof3dt1turbospinechoimagingfortheevaluationofintracranialstentplacement AT satokoji usefulnessof3dt1turbospinechoimagingfortheevaluationofintracranialstentplacement AT negishichikashi usefulnessof3dt1turbospinechoimagingfortheevaluationofintracranialstentplacement AT sasaguchinobuo usefulnessof3dt1turbospinechoimagingfortheevaluationofintracranialstentplacement AT kuriharahideyuki usefulnessof3dt1turbospinechoimagingfortheevaluationofintracranialstentplacement AT yoshimotoyuhei usefulnessof3dt1turbospinechoimagingfortheevaluationofintracranialstentplacement |