Cargando…
A Case of Coil Embolization with Crossing Y-Configuration Stenting for a Recurrent IC-PC Aneurysm after Clipping
OBJECTIVE: We report a case in which coil embolization using crossing Y-configuration stenting was effective for an internal carotid-posterior communicating artery (IC-PC) aneurysm with repeated recurrence after clipping. CASE PRESENTATION: The patient was a 57-year-old woman. Nine months after unde...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Japanese Society for Neuroendovascular Therapy
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10370556/ https://www.ncbi.nlm.nih.gov/pubmed/37502227 http://dx.doi.org/10.5797/jnet.cr.2021-0065 |
_version_ | 1785077959224197120 |
---|---|
author | Sato, Shinji Kokubo, Yasuaki Kawanami, Kanako Itagaki, Hiroshi Matsumoto, Yasushi Sonoda, Yukihiko |
author_facet | Sato, Shinji Kokubo, Yasuaki Kawanami, Kanako Itagaki, Hiroshi Matsumoto, Yasushi Sonoda, Yukihiko |
author_sort | Sato, Shinji |
collection | PubMed |
description | OBJECTIVE: We report a case in which coil embolization using crossing Y-configuration stenting was effective for an internal carotid-posterior communicating artery (IC-PC) aneurysm with repeated recurrence after clipping. CASE PRESENTATION: The patient was a 57-year-old woman. Nine months after undergoing clipping for a ruptured right IC-PC aneurysm at 55 years of age, she developed a second subarachnoid hemorrhage (SAH) due to recurrence of the aneurysm and underwent clipping at the same site. A third SAH due to rupture of the left IC-PC aneurysm developed 1.5 years after the second clipping. Simultaneously, recurrence of a right IC-PC aneurysm was noted and she was referred to our department. The recurrent right IC-PC aneurysm was considered to have originated from the distal to the initial neck. It was 7 mm in size and had an irregularly shaped wide neck. As it was assumed that there would be marked adhesion due to repeated surgery, we decided to treat the aneurysm by coil embolization instead of direct surgery. Although the aneurysm neck partially involved the posterior communicating artery (Pcom), tight packing with a minimal residual neck was required. Therefore, crossing Y-configuration stenting was deployed on the internal carotid artery and Pcom using two Neuroform Atlas stents, and coil embolization was performed by the jail technique. The recurrent aneurysm was obliterated. There were no deficits or thrombotic complications after surgery. On DSA follow-up, no compaction or recurrence was observed, and the Pcom was well visualized one year later. CONCLUSION: Coil embolization by crossing Y-configuration stenting is a viable treatment option for a recurrent IC-PC wide neck aneurysm. |
format | Online Article Text |
id | pubmed-10370556 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | The Japanese Society for Neuroendovascular Therapy |
record_format | MEDLINE/PubMed |
spelling | pubmed-103705562023-07-27 A Case of Coil Embolization with Crossing Y-Configuration Stenting for a Recurrent IC-PC Aneurysm after Clipping Sato, Shinji Kokubo, Yasuaki Kawanami, Kanako Itagaki, Hiroshi Matsumoto, Yasushi Sonoda, Yukihiko J Neuroendovasc Ther Case Report OBJECTIVE: We report a case in which coil embolization using crossing Y-configuration stenting was effective for an internal carotid-posterior communicating artery (IC-PC) aneurysm with repeated recurrence after clipping. CASE PRESENTATION: The patient was a 57-year-old woman. Nine months after undergoing clipping for a ruptured right IC-PC aneurysm at 55 years of age, she developed a second subarachnoid hemorrhage (SAH) due to recurrence of the aneurysm and underwent clipping at the same site. A third SAH due to rupture of the left IC-PC aneurysm developed 1.5 years after the second clipping. Simultaneously, recurrence of a right IC-PC aneurysm was noted and she was referred to our department. The recurrent right IC-PC aneurysm was considered to have originated from the distal to the initial neck. It was 7 mm in size and had an irregularly shaped wide neck. As it was assumed that there would be marked adhesion due to repeated surgery, we decided to treat the aneurysm by coil embolization instead of direct surgery. Although the aneurysm neck partially involved the posterior communicating artery (Pcom), tight packing with a minimal residual neck was required. Therefore, crossing Y-configuration stenting was deployed on the internal carotid artery and Pcom using two Neuroform Atlas stents, and coil embolization was performed by the jail technique. The recurrent aneurysm was obliterated. There were no deficits or thrombotic complications after surgery. On DSA follow-up, no compaction or recurrence was observed, and the Pcom was well visualized one year later. CONCLUSION: Coil embolization by crossing Y-configuration stenting is a viable treatment option for a recurrent IC-PC wide neck aneurysm. The Japanese Society for Neuroendovascular Therapy 2021-09-11 2022 /pmc/articles/PMC10370556/ /pubmed/37502227 http://dx.doi.org/10.5797/jnet.cr.2021-0065 Text en ©2022 The Japanese Society for Neuroendovascular Therapy https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives International License (https://creativecommons.org/licenses/by-nc-nd/4.0/) |
spellingShingle | Case Report Sato, Shinji Kokubo, Yasuaki Kawanami, Kanako Itagaki, Hiroshi Matsumoto, Yasushi Sonoda, Yukihiko A Case of Coil Embolization with Crossing Y-Configuration Stenting for a Recurrent IC-PC Aneurysm after Clipping |
title | A Case of Coil Embolization with Crossing Y-Configuration Stenting for a Recurrent IC-PC Aneurysm after Clipping |
title_full | A Case of Coil Embolization with Crossing Y-Configuration Stenting for a Recurrent IC-PC Aneurysm after Clipping |
title_fullStr | A Case of Coil Embolization with Crossing Y-Configuration Stenting for a Recurrent IC-PC Aneurysm after Clipping |
title_full_unstemmed | A Case of Coil Embolization with Crossing Y-Configuration Stenting for a Recurrent IC-PC Aneurysm after Clipping |
title_short | A Case of Coil Embolization with Crossing Y-Configuration Stenting for a Recurrent IC-PC Aneurysm after Clipping |
title_sort | case of coil embolization with crossing y-configuration stenting for a recurrent ic-pc aneurysm after clipping |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10370556/ https://www.ncbi.nlm.nih.gov/pubmed/37502227 http://dx.doi.org/10.5797/jnet.cr.2021-0065 |
work_keys_str_mv | AT satoshinji acaseofcoilembolizationwithcrossingyconfigurationstentingforarecurrenticpcaneurysmafterclipping AT kokuboyasuaki acaseofcoilembolizationwithcrossingyconfigurationstentingforarecurrenticpcaneurysmafterclipping AT kawanamikanako acaseofcoilembolizationwithcrossingyconfigurationstentingforarecurrenticpcaneurysmafterclipping AT itagakihiroshi acaseofcoilembolizationwithcrossingyconfigurationstentingforarecurrenticpcaneurysmafterclipping AT matsumotoyasushi acaseofcoilembolizationwithcrossingyconfigurationstentingforarecurrenticpcaneurysmafterclipping AT sonodayukihiko acaseofcoilembolizationwithcrossingyconfigurationstentingforarecurrenticpcaneurysmafterclipping AT satoshinji caseofcoilembolizationwithcrossingyconfigurationstentingforarecurrenticpcaneurysmafterclipping AT kokuboyasuaki caseofcoilembolizationwithcrossingyconfigurationstentingforarecurrenticpcaneurysmafterclipping AT kawanamikanako caseofcoilembolizationwithcrossingyconfigurationstentingforarecurrenticpcaneurysmafterclipping AT itagakihiroshi caseofcoilembolizationwithcrossingyconfigurationstentingforarecurrenticpcaneurysmafterclipping AT matsumotoyasushi caseofcoilembolizationwithcrossingyconfigurationstentingforarecurrenticpcaneurysmafterclipping AT sonodayukihiko caseofcoilembolizationwithcrossingyconfigurationstentingforarecurrenticpcaneurysmafterclipping |