Cargando…

A Case of Coil Embolization with Crossing Y-Configuration Stenting for a Recurrent IC-PC Aneurysm after Clipping

OBJECTIVE: We report a case in which coil embolization using crossing Y-configuration stenting was effective for an internal carotid-posterior communicating artery (IC-PC) aneurysm with repeated recurrence after clipping. CASE PRESENTATION: The patient was a 57-year-old woman. Nine months after unde...

Descripción completa

Detalles Bibliográficos
Autores principales: Sato, Shinji, Kokubo, Yasuaki, Kawanami, Kanako, Itagaki, Hiroshi, Matsumoto, Yasushi, Sonoda, Yukihiko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Japanese Society for Neuroendovascular Therapy 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10370556/
https://www.ncbi.nlm.nih.gov/pubmed/37502227
http://dx.doi.org/10.5797/jnet.cr.2021-0065
_version_ 1785077959224197120
author Sato, Shinji
Kokubo, Yasuaki
Kawanami, Kanako
Itagaki, Hiroshi
Matsumoto, Yasushi
Sonoda, Yukihiko
author_facet Sato, Shinji
Kokubo, Yasuaki
Kawanami, Kanako
Itagaki, Hiroshi
Matsumoto, Yasushi
Sonoda, Yukihiko
author_sort Sato, Shinji
collection PubMed
description OBJECTIVE: We report a case in which coil embolization using crossing Y-configuration stenting was effective for an internal carotid-posterior communicating artery (IC-PC) aneurysm with repeated recurrence after clipping. CASE PRESENTATION: The patient was a 57-year-old woman. Nine months after undergoing clipping for a ruptured right IC-PC aneurysm at 55 years of age, she developed a second subarachnoid hemorrhage (SAH) due to recurrence of the aneurysm and underwent clipping at the same site. A third SAH due to rupture of the left IC-PC aneurysm developed 1.5 years after the second clipping. Simultaneously, recurrence of a right IC-PC aneurysm was noted and she was referred to our department. The recurrent right IC-PC aneurysm was considered to have originated from the distal to the initial neck. It was 7 mm in size and had an irregularly shaped wide neck. As it was assumed that there would be marked adhesion due to repeated surgery, we decided to treat the aneurysm by coil embolization instead of direct surgery. Although the aneurysm neck partially involved the posterior communicating artery (Pcom), tight packing with a minimal residual neck was required. Therefore, crossing Y-configuration stenting was deployed on the internal carotid artery and Pcom using two Neuroform Atlas stents, and coil embolization was performed by the jail technique. The recurrent aneurysm was obliterated. There were no deficits or thrombotic complications after surgery. On DSA follow-up, no compaction or recurrence was observed, and the Pcom was well visualized one year later. CONCLUSION: Coil embolization by crossing Y-configuration stenting is a viable treatment option for a recurrent IC-PC wide neck aneurysm.
format Online
Article
Text
id pubmed-10370556
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Japanese Society for Neuroendovascular Therapy
record_format MEDLINE/PubMed
spelling pubmed-103705562023-07-27 A Case of Coil Embolization with Crossing Y-Configuration Stenting for a Recurrent IC-PC Aneurysm after Clipping Sato, Shinji Kokubo, Yasuaki Kawanami, Kanako Itagaki, Hiroshi Matsumoto, Yasushi Sonoda, Yukihiko J Neuroendovasc Ther Case Report OBJECTIVE: We report a case in which coil embolization using crossing Y-configuration stenting was effective for an internal carotid-posterior communicating artery (IC-PC) aneurysm with repeated recurrence after clipping. CASE PRESENTATION: The patient was a 57-year-old woman. Nine months after undergoing clipping for a ruptured right IC-PC aneurysm at 55 years of age, she developed a second subarachnoid hemorrhage (SAH) due to recurrence of the aneurysm and underwent clipping at the same site. A third SAH due to rupture of the left IC-PC aneurysm developed 1.5 years after the second clipping. Simultaneously, recurrence of a right IC-PC aneurysm was noted and she was referred to our department. The recurrent right IC-PC aneurysm was considered to have originated from the distal to the initial neck. It was 7 mm in size and had an irregularly shaped wide neck. As it was assumed that there would be marked adhesion due to repeated surgery, we decided to treat the aneurysm by coil embolization instead of direct surgery. Although the aneurysm neck partially involved the posterior communicating artery (Pcom), tight packing with a minimal residual neck was required. Therefore, crossing Y-configuration stenting was deployed on the internal carotid artery and Pcom using two Neuroform Atlas stents, and coil embolization was performed by the jail technique. The recurrent aneurysm was obliterated. There were no deficits or thrombotic complications after surgery. On DSA follow-up, no compaction or recurrence was observed, and the Pcom was well visualized one year later. CONCLUSION: Coil embolization by crossing Y-configuration stenting is a viable treatment option for a recurrent IC-PC wide neck aneurysm. The Japanese Society for Neuroendovascular Therapy 2021-09-11 2022 /pmc/articles/PMC10370556/ /pubmed/37502227 http://dx.doi.org/10.5797/jnet.cr.2021-0065 Text en ©2022 The Japanese Society for Neuroendovascular Therapy https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives International License (https://creativecommons.org/licenses/by-nc-nd/4.0/)
spellingShingle Case Report
Sato, Shinji
Kokubo, Yasuaki
Kawanami, Kanako
Itagaki, Hiroshi
Matsumoto, Yasushi
Sonoda, Yukihiko
A Case of Coil Embolization with Crossing Y-Configuration Stenting for a Recurrent IC-PC Aneurysm after Clipping
title A Case of Coil Embolization with Crossing Y-Configuration Stenting for a Recurrent IC-PC Aneurysm after Clipping
title_full A Case of Coil Embolization with Crossing Y-Configuration Stenting for a Recurrent IC-PC Aneurysm after Clipping
title_fullStr A Case of Coil Embolization with Crossing Y-Configuration Stenting for a Recurrent IC-PC Aneurysm after Clipping
title_full_unstemmed A Case of Coil Embolization with Crossing Y-Configuration Stenting for a Recurrent IC-PC Aneurysm after Clipping
title_short A Case of Coil Embolization with Crossing Y-Configuration Stenting for a Recurrent IC-PC Aneurysm after Clipping
title_sort case of coil embolization with crossing y-configuration stenting for a recurrent ic-pc aneurysm after clipping
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10370556/
https://www.ncbi.nlm.nih.gov/pubmed/37502227
http://dx.doi.org/10.5797/jnet.cr.2021-0065
work_keys_str_mv AT satoshinji acaseofcoilembolizationwithcrossingyconfigurationstentingforarecurrenticpcaneurysmafterclipping
AT kokuboyasuaki acaseofcoilembolizationwithcrossingyconfigurationstentingforarecurrenticpcaneurysmafterclipping
AT kawanamikanako acaseofcoilembolizationwithcrossingyconfigurationstentingforarecurrenticpcaneurysmafterclipping
AT itagakihiroshi acaseofcoilembolizationwithcrossingyconfigurationstentingforarecurrenticpcaneurysmafterclipping
AT matsumotoyasushi acaseofcoilembolizationwithcrossingyconfigurationstentingforarecurrenticpcaneurysmafterclipping
AT sonodayukihiko acaseofcoilembolizationwithcrossingyconfigurationstentingforarecurrenticpcaneurysmafterclipping
AT satoshinji caseofcoilembolizationwithcrossingyconfigurationstentingforarecurrenticpcaneurysmafterclipping
AT kokuboyasuaki caseofcoilembolizationwithcrossingyconfigurationstentingforarecurrenticpcaneurysmafterclipping
AT kawanamikanako caseofcoilembolizationwithcrossingyconfigurationstentingforarecurrenticpcaneurysmafterclipping
AT itagakihiroshi caseofcoilembolizationwithcrossingyconfigurationstentingforarecurrenticpcaneurysmafterclipping
AT matsumotoyasushi caseofcoilembolizationwithcrossingyconfigurationstentingforarecurrenticpcaneurysmafterclipping
AT sonodayukihiko caseofcoilembolizationwithcrossingyconfigurationstentingforarecurrenticpcaneurysmafterclipping