Cargando…
Mechanical Thrombectomy via the Transfemoral Approach for Acute Middle Cerebral Artery M1 Occlusion That Occurred during Intra-Aortic Balloon Pumping Application
OBJECTIVE: We report a case of cardioembolic stroke treated by mechanical thrombectomy (MT) via the transfemoral approach under the assistance of intra-aortic balloon pumping (IABP). CASE PRESENTATION: A 64-year-old man suddenly developed consciousness disturbance, aphasia, and left hemiparesis duri...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Japanese Society for Neuroendovascular Therapy
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10370673/ https://www.ncbi.nlm.nih.gov/pubmed/37502732 http://dx.doi.org/10.5797/jnet.cr.2020-0073 |
_version_ | 1785077986346663936 |
---|---|
author | Eto, Futoshi Nagao, Yoichiro Kuramoto, Yoji Takagi, Toshinori Uchida, Kazutaka Yoshimura, Shinichi |
author_facet | Eto, Futoshi Nagao, Yoichiro Kuramoto, Yoji Takagi, Toshinori Uchida, Kazutaka Yoshimura, Shinichi |
author_sort | Eto, Futoshi |
collection | PubMed |
description | OBJECTIVE: We report a case of cardioembolic stroke treated by mechanical thrombectomy (MT) via the transfemoral approach under the assistance of intra-aortic balloon pumping (IABP). CASE PRESENTATION: A 64-year-old man suddenly developed consciousness disturbance, aphasia, and left hemiparesis during intensive care for acute myocardial infarction (AMI) with IABP. The patient was transferred to our hospital and diagnosed with acute right middle cerebral artery (MCA) occlusion. We performed MT using a balloon-guiding catheter via the transfemoral approach and achieved complete recanalization. CONCLUSION: Endovascular therapy for acute MCA M1 occlusion via the transfemoral route was safe even when the patient was treated using IABP. |
format | Online Article Text |
id | pubmed-10370673 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | The Japanese Society for Neuroendovascular Therapy |
record_format | MEDLINE/PubMed |
spelling | pubmed-103706732023-07-27 Mechanical Thrombectomy via the Transfemoral Approach for Acute Middle Cerebral Artery M1 Occlusion That Occurred during Intra-Aortic Balloon Pumping Application Eto, Futoshi Nagao, Yoichiro Kuramoto, Yoji Takagi, Toshinori Uchida, Kazutaka Yoshimura, Shinichi J Neuroendovasc Ther Case Report OBJECTIVE: We report a case of cardioembolic stroke treated by mechanical thrombectomy (MT) via the transfemoral approach under the assistance of intra-aortic balloon pumping (IABP). CASE PRESENTATION: A 64-year-old man suddenly developed consciousness disturbance, aphasia, and left hemiparesis during intensive care for acute myocardial infarction (AMI) with IABP. The patient was transferred to our hospital and diagnosed with acute right middle cerebral artery (MCA) occlusion. We performed MT using a balloon-guiding catheter via the transfemoral approach and achieved complete recanalization. CONCLUSION: Endovascular therapy for acute MCA M1 occlusion via the transfemoral route was safe even when the patient was treated using IABP. The Japanese Society for Neuroendovascular Therapy 2020-09-30 2021 /pmc/articles/PMC10370673/ /pubmed/37502732 http://dx.doi.org/10.5797/jnet.cr.2020-0073 Text en ©2021 The Japanese Society for Neuroendovascular Therapy https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives International License (https://creativecommons.org/licenses/by-nc-nd/4.0/) |
spellingShingle | Case Report Eto, Futoshi Nagao, Yoichiro Kuramoto, Yoji Takagi, Toshinori Uchida, Kazutaka Yoshimura, Shinichi Mechanical Thrombectomy via the Transfemoral Approach for Acute Middle Cerebral Artery M1 Occlusion That Occurred during Intra-Aortic Balloon Pumping Application |
title | Mechanical Thrombectomy via the Transfemoral Approach for Acute Middle Cerebral Artery M1 Occlusion That Occurred during Intra-Aortic Balloon Pumping Application |
title_full | Mechanical Thrombectomy via the Transfemoral Approach for Acute Middle Cerebral Artery M1 Occlusion That Occurred during Intra-Aortic Balloon Pumping Application |
title_fullStr | Mechanical Thrombectomy via the Transfemoral Approach for Acute Middle Cerebral Artery M1 Occlusion That Occurred during Intra-Aortic Balloon Pumping Application |
title_full_unstemmed | Mechanical Thrombectomy via the Transfemoral Approach for Acute Middle Cerebral Artery M1 Occlusion That Occurred during Intra-Aortic Balloon Pumping Application |
title_short | Mechanical Thrombectomy via the Transfemoral Approach for Acute Middle Cerebral Artery M1 Occlusion That Occurred during Intra-Aortic Balloon Pumping Application |
title_sort | mechanical thrombectomy via the transfemoral approach for acute middle cerebral artery m1 occlusion that occurred during intra-aortic balloon pumping application |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10370673/ https://www.ncbi.nlm.nih.gov/pubmed/37502732 http://dx.doi.org/10.5797/jnet.cr.2020-0073 |
work_keys_str_mv | AT etofutoshi mechanicalthrombectomyviathetransfemoralapproachforacutemiddlecerebralarterym1occlusionthatoccurredduringintraaorticballoonpumpingapplication AT nagaoyoichiro mechanicalthrombectomyviathetransfemoralapproachforacutemiddlecerebralarterym1occlusionthatoccurredduringintraaorticballoonpumpingapplication AT kuramotoyoji mechanicalthrombectomyviathetransfemoralapproachforacutemiddlecerebralarterym1occlusionthatoccurredduringintraaorticballoonpumpingapplication AT takagitoshinori mechanicalthrombectomyviathetransfemoralapproachforacutemiddlecerebralarterym1occlusionthatoccurredduringintraaorticballoonpumpingapplication AT uchidakazutaka mechanicalthrombectomyviathetransfemoralapproachforacutemiddlecerebralarterym1occlusionthatoccurredduringintraaorticballoonpumpingapplication AT yoshimurashinichi mechanicalthrombectomyviathetransfemoralapproachforacutemiddlecerebralarterym1occlusionthatoccurredduringintraaorticballoonpumpingapplication |