Cargando…
Usefulness of the Double-Lumen Super-Compliant Balloon Catheter “Super-Masamune” for Balloon-Assisted Coil Embolization of Carotid–Cavernous Fistulas
OBJECTIVE: Transarterial embolization (TAE) of the cavernous sinus (CS) via a fistula formed in the internal carotid artery (ICA) is the standard for carotid-cavernous fistulas (CCFs). Depending on the fistula, an adjunctive technique using a balloon or stent is effective. We report a case in which...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Japanese Society for Neuroendovascular Therapy
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10370795/ https://www.ncbi.nlm.nih.gov/pubmed/37501750 http://dx.doi.org/10.5797/jnet.cr.2020-0110 |
_version_ | 1785078013205938176 |
---|---|
author | Morita, Takahiro Niizuma, Kuniyasu Endo, Hidenori Tominaga, Teiji |
author_facet | Morita, Takahiro Niizuma, Kuniyasu Endo, Hidenori Tominaga, Teiji |
author_sort | Morita, Takahiro |
collection | PubMed |
description | OBJECTIVE: Transarterial embolization (TAE) of the cavernous sinus (CS) via a fistula formed in the internal carotid artery (ICA) is the standard for carotid-cavernous fistulas (CCFs). Depending on the fistula, an adjunctive technique using a balloon or stent is effective. We report a case in which the balloon-assisted technique using the super-compliant balloon catheter “Super-Masamune” was effective. CASE PRESENTATION: A 44-year-old woman who sustained head trauma from a traffic accident 1 month prior presented with diplopia, conjunctival chemosis, and proptosis of the left eye. Digital subtraction angiography (DSA) revealed a left CCF with a reflex to the left superior ophthalmic vein (SOV). During TAE with the Super-Masamune assistance, we tightly embolized around the fistula using a small volume of coils and the CCF was obliterated. CONCLUSION: The balloon of the Super-Masamune is made of a styrene-based elastomer, which has excellent compliance. Therefore, it is possible to reduce the volume of coils because the balloon is in close contact with the ICA or fistula. This may reduce the incidence of postoperative cranial nerve palsy and cost of treatment materials. |
format | Online Article Text |
id | pubmed-10370795 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | The Japanese Society for Neuroendovascular Therapy |
record_format | MEDLINE/PubMed |
spelling | pubmed-103707952023-07-27 Usefulness of the Double-Lumen Super-Compliant Balloon Catheter “Super-Masamune” for Balloon-Assisted Coil Embolization of Carotid–Cavernous Fistulas Morita, Takahiro Niizuma, Kuniyasu Endo, Hidenori Tominaga, Teiji J Neuroendovasc Ther Case Report OBJECTIVE: Transarterial embolization (TAE) of the cavernous sinus (CS) via a fistula formed in the internal carotid artery (ICA) is the standard for carotid-cavernous fistulas (CCFs). Depending on the fistula, an adjunctive technique using a balloon or stent is effective. We report a case in which the balloon-assisted technique using the super-compliant balloon catheter “Super-Masamune” was effective. CASE PRESENTATION: A 44-year-old woman who sustained head trauma from a traffic accident 1 month prior presented with diplopia, conjunctival chemosis, and proptosis of the left eye. Digital subtraction angiography (DSA) revealed a left CCF with a reflex to the left superior ophthalmic vein (SOV). During TAE with the Super-Masamune assistance, we tightly embolized around the fistula using a small volume of coils and the CCF was obliterated. CONCLUSION: The balloon of the Super-Masamune is made of a styrene-based elastomer, which has excellent compliance. Therefore, it is possible to reduce the volume of coils because the balloon is in close contact with the ICA or fistula. This may reduce the incidence of postoperative cranial nerve palsy and cost of treatment materials. The Japanese Society for Neuroendovascular Therapy 2021-01-20 2021 /pmc/articles/PMC10370795/ /pubmed/37501750 http://dx.doi.org/10.5797/jnet.cr.2020-0110 Text en ©2021 The Japanese Society for Neuroendovascular Therapy https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives International License (https://creativecommons.org/licenses/by-nc-nd/4.0/) |
spellingShingle | Case Report Morita, Takahiro Niizuma, Kuniyasu Endo, Hidenori Tominaga, Teiji Usefulness of the Double-Lumen Super-Compliant Balloon Catheter “Super-Masamune” for Balloon-Assisted Coil Embolization of Carotid–Cavernous Fistulas |
title | Usefulness of the Double-Lumen Super-Compliant Balloon Catheter “Super-Masamune” for Balloon-Assisted Coil Embolization of Carotid–Cavernous Fistulas |
title_full | Usefulness of the Double-Lumen Super-Compliant Balloon Catheter “Super-Masamune” for Balloon-Assisted Coil Embolization of Carotid–Cavernous Fistulas |
title_fullStr | Usefulness of the Double-Lumen Super-Compliant Balloon Catheter “Super-Masamune” for Balloon-Assisted Coil Embolization of Carotid–Cavernous Fistulas |
title_full_unstemmed | Usefulness of the Double-Lumen Super-Compliant Balloon Catheter “Super-Masamune” for Balloon-Assisted Coil Embolization of Carotid–Cavernous Fistulas |
title_short | Usefulness of the Double-Lumen Super-Compliant Balloon Catheter “Super-Masamune” for Balloon-Assisted Coil Embolization of Carotid–Cavernous Fistulas |
title_sort | usefulness of the double-lumen super-compliant balloon catheter “super-masamune” for balloon-assisted coil embolization of carotid–cavernous fistulas |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10370795/ https://www.ncbi.nlm.nih.gov/pubmed/37501750 http://dx.doi.org/10.5797/jnet.cr.2020-0110 |
work_keys_str_mv | AT moritatakahiro usefulnessofthedoublelumensupercompliantballooncathetersupermasamuneforballoonassistedcoilembolizationofcarotidcavernousfistulas AT niizumakuniyasu usefulnessofthedoublelumensupercompliantballooncathetersupermasamuneforballoonassistedcoilembolizationofcarotidcavernousfistulas AT endohidenori usefulnessofthedoublelumensupercompliantballooncathetersupermasamuneforballoonassistedcoilembolizationofcarotidcavernousfistulas AT tominagateiji usefulnessofthedoublelumensupercompliantballooncathetersupermasamuneforballoonassistedcoilembolizationofcarotidcavernousfistulas |