Cargando…

Usefulness of the Double-Lumen Super-Compliant Balloon Catheter “Super-Masamune” for Balloon-Assisted Coil Embolization of Carotid–Cavernous Fistulas

OBJECTIVE: Transarterial embolization (TAE) of the cavernous sinus (CS) via a fistula formed in the internal carotid artery (ICA) is the standard for carotid-cavernous fistulas (CCFs). Depending on the fistula, an adjunctive technique using a balloon or stent is effective. We report a case in which...

Descripción completa

Detalles Bibliográficos
Autores principales: Morita, Takahiro, Niizuma, Kuniyasu, Endo, Hidenori, Tominaga, Teiji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Japanese Society for Neuroendovascular Therapy 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10370795/
https://www.ncbi.nlm.nih.gov/pubmed/37501750
http://dx.doi.org/10.5797/jnet.cr.2020-0110
_version_ 1785078013205938176
author Morita, Takahiro
Niizuma, Kuniyasu
Endo, Hidenori
Tominaga, Teiji
author_facet Morita, Takahiro
Niizuma, Kuniyasu
Endo, Hidenori
Tominaga, Teiji
author_sort Morita, Takahiro
collection PubMed
description OBJECTIVE: Transarterial embolization (TAE) of the cavernous sinus (CS) via a fistula formed in the internal carotid artery (ICA) is the standard for carotid-cavernous fistulas (CCFs). Depending on the fistula, an adjunctive technique using a balloon or stent is effective. We report a case in which the balloon-assisted technique using the super-compliant balloon catheter “Super-Masamune” was effective. CASE PRESENTATION: A 44-year-old woman who sustained head trauma from a traffic accident 1 month prior presented with diplopia, conjunctival chemosis, and proptosis of the left eye. Digital subtraction angiography (DSA) revealed a left CCF with a reflex to the left superior ophthalmic vein (SOV). During TAE with the Super-Masamune assistance, we tightly embolized around the fistula using a small volume of coils and the CCF was obliterated. CONCLUSION: The balloon of the Super-Masamune is made of a styrene-based elastomer, which has excellent compliance. Therefore, it is possible to reduce the volume of coils because the balloon is in close contact with the ICA or fistula. This may reduce the incidence of postoperative cranial nerve palsy and cost of treatment materials.
format Online
Article
Text
id pubmed-10370795
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Japanese Society for Neuroendovascular Therapy
record_format MEDLINE/PubMed
spelling pubmed-103707952023-07-27 Usefulness of the Double-Lumen Super-Compliant Balloon Catheter “Super-Masamune” for Balloon-Assisted Coil Embolization of Carotid–Cavernous Fistulas Morita, Takahiro Niizuma, Kuniyasu Endo, Hidenori Tominaga, Teiji J Neuroendovasc Ther Case Report OBJECTIVE: Transarterial embolization (TAE) of the cavernous sinus (CS) via a fistula formed in the internal carotid artery (ICA) is the standard for carotid-cavernous fistulas (CCFs). Depending on the fistula, an adjunctive technique using a balloon or stent is effective. We report a case in which the balloon-assisted technique using the super-compliant balloon catheter “Super-Masamune” was effective. CASE PRESENTATION: A 44-year-old woman who sustained head trauma from a traffic accident 1 month prior presented with diplopia, conjunctival chemosis, and proptosis of the left eye. Digital subtraction angiography (DSA) revealed a left CCF with a reflex to the left superior ophthalmic vein (SOV). During TAE with the Super-Masamune assistance, we tightly embolized around the fistula using a small volume of coils and the CCF was obliterated. CONCLUSION: The balloon of the Super-Masamune is made of a styrene-based elastomer, which has excellent compliance. Therefore, it is possible to reduce the volume of coils because the balloon is in close contact with the ICA or fistula. This may reduce the incidence of postoperative cranial nerve palsy and cost of treatment materials. The Japanese Society for Neuroendovascular Therapy 2021-01-20 2021 /pmc/articles/PMC10370795/ /pubmed/37501750 http://dx.doi.org/10.5797/jnet.cr.2020-0110 Text en ©2021 The Japanese Society for Neuroendovascular Therapy https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives International License (https://creativecommons.org/licenses/by-nc-nd/4.0/)
spellingShingle Case Report
Morita, Takahiro
Niizuma, Kuniyasu
Endo, Hidenori
Tominaga, Teiji
Usefulness of the Double-Lumen Super-Compliant Balloon Catheter “Super-Masamune” for Balloon-Assisted Coil Embolization of Carotid–Cavernous Fistulas
title Usefulness of the Double-Lumen Super-Compliant Balloon Catheter “Super-Masamune” for Balloon-Assisted Coil Embolization of Carotid–Cavernous Fistulas
title_full Usefulness of the Double-Lumen Super-Compliant Balloon Catheter “Super-Masamune” for Balloon-Assisted Coil Embolization of Carotid–Cavernous Fistulas
title_fullStr Usefulness of the Double-Lumen Super-Compliant Balloon Catheter “Super-Masamune” for Balloon-Assisted Coil Embolization of Carotid–Cavernous Fistulas
title_full_unstemmed Usefulness of the Double-Lumen Super-Compliant Balloon Catheter “Super-Masamune” for Balloon-Assisted Coil Embolization of Carotid–Cavernous Fistulas
title_short Usefulness of the Double-Lumen Super-Compliant Balloon Catheter “Super-Masamune” for Balloon-Assisted Coil Embolization of Carotid–Cavernous Fistulas
title_sort usefulness of the double-lumen super-compliant balloon catheter “super-masamune” for balloon-assisted coil embolization of carotid–cavernous fistulas
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10370795/
https://www.ncbi.nlm.nih.gov/pubmed/37501750
http://dx.doi.org/10.5797/jnet.cr.2020-0110
work_keys_str_mv AT moritatakahiro usefulnessofthedoublelumensupercompliantballooncathetersupermasamuneforballoonassistedcoilembolizationofcarotidcavernousfistulas
AT niizumakuniyasu usefulnessofthedoublelumensupercompliantballooncathetersupermasamuneforballoonassistedcoilembolizationofcarotidcavernousfistulas
AT endohidenori usefulnessofthedoublelumensupercompliantballooncathetersupermasamuneforballoonassistedcoilembolizationofcarotidcavernousfistulas
AT tominagateiji usefulnessofthedoublelumensupercompliantballooncathetersupermasamuneforballoonassistedcoilembolizationofcarotidcavernousfistulas