Cargando…

Validity of PETRA-MRA for Stent-Assisted Coil Embolization of Intracranial Aneurysms

OBJECTIVE: Pointwise encoding time reduction with radial acquisition (PETRA) using magnetic resonance angiography (MRA) is a non-enhanced MRA technique employing an ultrashort echo time, and is known to significantly reduce the magnetic susceptibility of coils and stents during post-embolization ima...

Descripción completa

Detalles Bibliográficos
Autores principales: Sato, Keisuke, Asano, Akihiro, Kobayashi, Tsutomu, Aoki, Hiroshi, Jinguji, Shinya, Seto, Hiroki, Demachi, Hiroshi, Hasegawa, Hitoshi, Fujii, Yukihiko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Japanese Society for Neuroendovascular Therapy 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10370957/
https://www.ncbi.nlm.nih.gov/pubmed/37502413
http://dx.doi.org/10.5797/jnet.oa.2020-0039
Descripción
Sumario:OBJECTIVE: Pointwise encoding time reduction with radial acquisition (PETRA) using magnetic resonance angiography (MRA) is a non-enhanced MRA technique employing an ultrashort echo time, and is known to significantly reduce the magnetic susceptibility of coils and stents during post-embolization imaging. We evaluated the quality of PETRA-MRA images for use at the follow-up assessment of stent-assisted coil embolization procedures performed to treat aneurysms. METHODS: A total of six aneurysm patients who were treated by stent-assisted coil embolization were included. All patients underwent PETRA-MRA, time-of-flight (TOF)-MRA performed with MAGNETOM Skyra (Siemens), and digital subtraction angiography (DSA) performed with Infinix Celeve-i INFX-8000V (Canon Medical Systems) and Allura Clarity FD20/15 (Philips). The PETRA-MRA images were compared with those from DSA and TOF-MRA to validate the aneurysm occlusion status and visually assess the blood flow within the stent. Four independent specialists graded occlusion status and flow visualization through the stent using a four-point scale, where 4 points represented excellent visualization of flow within the stent. RESULTS: The aneurysm was located in the internal carotid artery in two patients, the middle cerebral artery in two patients, the top of the basilar artery in one patient, and the vertebral artery-posterior inferior cerebellar artery (VA-PICA) in one patient. Three patients were treated using a Neuroform Atlas Stent system, one using an Enterprise2 VRD, one using two Neuroform Atlas stents for Y-stenting, and the remaining patient using a Neuroform Atlas and an Enterprise2 VRD for Y-stenting. With DSA, the postoperative aneurysm occlusion status was neck remnant (NR) in five cases and complete obliteration (CO) in one case. DSA and PETRA-MRA evaluations demonstrated an equal occlusion status in five of six cases, whereas DSA and TOF-MRA were equal in two of six cases. The mean visualization score for PETRA-MRA was 3.33 ± 0.82, whereas that for TOF-MRA was 2.17 ± 1.33. On the PETRA-MRA images, blood flow through the stent was well-visualized and produced an aneurysm occlusion status score comparable to DSA, especially in the three cases using the Neuroform Atlas Stent System where the visualization was scored 4 points. In the case of the VA-PICA aneurysm, for which an Enterprise2 VRD was used, PETRA-MRA images were insufficient for postoperative assessment. CONCLUSION: PETRA-MRA can provide good visualization of the blood flow within a stent and displays a clear blood signal near the coils, barring small magnetic susceptibility artifacts. Therefore, PETRA-MRA may be an effective option for follow-up imaging after stent-assisted coil embolization.