Cargando…
Thrombectomy for Small-Artery Occlusions with the Small-Diameter Stent Retriever, Tron Fx 2 mm × 15 mm: A Case Series
OBJECTIVE: The safety and efficacy of thrombectomy for small-artery occlusions is still controversial. In April 2019, Tron Fx, a stent retriever with an expansion diameter of 2 mm, became reimbursed by health insurance in Japan. We report on cases of thrombectomy for small-artery occlusions performe...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Japanese Society for Neuroendovascular Therapy
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10370981/ https://www.ncbi.nlm.nih.gov/pubmed/37501907 http://dx.doi.org/10.5797/jnet.oa.2020-0153 |
_version_ | 1785078055520174080 |
---|---|
author | Kitazawa, Keiko Ito, Yasushi Koyama, Miyako Ohara, Hiroshi Minagawa, Makoto |
author_facet | Kitazawa, Keiko Ito, Yasushi Koyama, Miyako Ohara, Hiroshi Minagawa, Makoto |
author_sort | Kitazawa, Keiko |
collection | PubMed |
description | OBJECTIVE: The safety and efficacy of thrombectomy for small-artery occlusions is still controversial. In April 2019, Tron Fx, a stent retriever with an expansion diameter of 2 mm, became reimbursed by health insurance in Japan. We report on cases of thrombectomy for small-artery occlusions performed using this device in seven patients. METHODS: The subjects were seven patients who underwent thrombectomy between July 2019 and June 2020 using Tron Fx with 2 mm in diameter. We analyzed clinical results including recanalization and complications. RESULTS: The mean age of the seven patients was 80.1 years, and the subjects included six men. The sites of occlusion were the middle cerebral artery M2 (n = 4), M4 (n = 1), anterior cerebral artery A2 (n = 1), and A3 (n = 1). One of the seven patients had an M2 occlusion that was formed during coil embolization for a ruptured cerebral aneurysm. In five cases, four cases were of primary occlusion and one case was of emboli into a new territory, treating with only Tron Fx 2 mm resulted in thrombolysis in cerebral infarction (TICI) 2b–3 in four cases. There was one case of grade 0, which was M4 occlusion. Finally, TICI 2b–3 were achieved in six of seven cases. No symptomatic intracranial hemorrhage occurred. Symptoms improved in five of six patients, excluding a vascular occlusion that occurred during surgery. CONCLUSION: Tron Fx with 2 mm diameter can be used safely for small-artery occlusion. The introduction of Tron Fx with 2 mm diameter may contribute to expand indications for thrombectomy for small-artery occlusions. |
format | Online Article Text |
id | pubmed-10370981 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | The Japanese Society for Neuroendovascular Therapy |
record_format | MEDLINE/PubMed |
spelling | pubmed-103709812023-07-27 Thrombectomy for Small-Artery Occlusions with the Small-Diameter Stent Retriever, Tron Fx 2 mm × 15 mm: A Case Series Kitazawa, Keiko Ito, Yasushi Koyama, Miyako Ohara, Hiroshi Minagawa, Makoto J Neuroendovasc Ther Original Article OBJECTIVE: The safety and efficacy of thrombectomy for small-artery occlusions is still controversial. In April 2019, Tron Fx, a stent retriever with an expansion diameter of 2 mm, became reimbursed by health insurance in Japan. We report on cases of thrombectomy for small-artery occlusions performed using this device in seven patients. METHODS: The subjects were seven patients who underwent thrombectomy between July 2019 and June 2020 using Tron Fx with 2 mm in diameter. We analyzed clinical results including recanalization and complications. RESULTS: The mean age of the seven patients was 80.1 years, and the subjects included six men. The sites of occlusion were the middle cerebral artery M2 (n = 4), M4 (n = 1), anterior cerebral artery A2 (n = 1), and A3 (n = 1). One of the seven patients had an M2 occlusion that was formed during coil embolization for a ruptured cerebral aneurysm. In five cases, four cases were of primary occlusion and one case was of emboli into a new territory, treating with only Tron Fx 2 mm resulted in thrombolysis in cerebral infarction (TICI) 2b–3 in four cases. There was one case of grade 0, which was M4 occlusion. Finally, TICI 2b–3 were achieved in six of seven cases. No symptomatic intracranial hemorrhage occurred. Symptoms improved in five of six patients, excluding a vascular occlusion that occurred during surgery. CONCLUSION: Tron Fx with 2 mm diameter can be used safely for small-artery occlusion. The introduction of Tron Fx with 2 mm diameter may contribute to expand indications for thrombectomy for small-artery occlusions. The Japanese Society for Neuroendovascular Therapy 2021-03-06 2021 /pmc/articles/PMC10370981/ /pubmed/37501907 http://dx.doi.org/10.5797/jnet.oa.2020-0153 Text en ©2021 The Japanese Society for Neuroendovascular Therapy https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives International License (https://creativecommons.org/licenses/by-nc-nd/4.0/) |
spellingShingle | Original Article Kitazawa, Keiko Ito, Yasushi Koyama, Miyako Ohara, Hiroshi Minagawa, Makoto Thrombectomy for Small-Artery Occlusions with the Small-Diameter Stent Retriever, Tron Fx 2 mm × 15 mm: A Case Series |
title | Thrombectomy for Small-Artery Occlusions with the Small-Diameter Stent Retriever, Tron Fx 2 mm × 15 mm: A Case Series |
title_full | Thrombectomy for Small-Artery Occlusions with the Small-Diameter Stent Retriever, Tron Fx 2 mm × 15 mm: A Case Series |
title_fullStr | Thrombectomy for Small-Artery Occlusions with the Small-Diameter Stent Retriever, Tron Fx 2 mm × 15 mm: A Case Series |
title_full_unstemmed | Thrombectomy for Small-Artery Occlusions with the Small-Diameter Stent Retriever, Tron Fx 2 mm × 15 mm: A Case Series |
title_short | Thrombectomy for Small-Artery Occlusions with the Small-Diameter Stent Retriever, Tron Fx 2 mm × 15 mm: A Case Series |
title_sort | thrombectomy for small-artery occlusions with the small-diameter stent retriever, tron fx 2 mm × 15 mm: a case series |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10370981/ https://www.ncbi.nlm.nih.gov/pubmed/37501907 http://dx.doi.org/10.5797/jnet.oa.2020-0153 |
work_keys_str_mv | AT kitazawakeiko thrombectomyforsmallarteryocclusionswiththesmalldiameterstentretrievertronfx2mm15mmacaseseries AT itoyasushi thrombectomyforsmallarteryocclusionswiththesmalldiameterstentretrievertronfx2mm15mmacaseseries AT koyamamiyako thrombectomyforsmallarteryocclusionswiththesmalldiameterstentretrievertronfx2mm15mmacaseseries AT oharahiroshi thrombectomyforsmallarteryocclusionswiththesmalldiameterstentretrievertronfx2mm15mmacaseseries AT minagawamakoto thrombectomyforsmallarteryocclusionswiththesmalldiameterstentretrievertronfx2mm15mmacaseseries |