Cargando…

Imprecision nutrition? Duplicate meals result in unreliable individual glycemic responses measured by continuous glucose monitors across three dietary patterns in adults without diabetes

BACKGROUND: Continuous glucose monitors (CGMs) are being used to characterize postprandial glycemic responses and thereby provide personalized dietary advice to minimize glycemic excursions. However, the efficacy of such advice depends on reliable CGM responses. OBJECTIVE: To explore within-subject...

Descripción completa

Detalles Bibliográficos
Autores principales: Hengist, Aaron, Guo, Juen, Hall, Kevin D
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cold Spring Harbor Laboratory 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10371100/
https://www.ncbi.nlm.nih.gov/pubmed/37503002
http://dx.doi.org/10.1101/2023.06.14.23291406
_version_ 1785078082251522048
author Hengist, Aaron
Guo, Juen
Hall, Kevin D
author_facet Hengist, Aaron
Guo, Juen
Hall, Kevin D
author_sort Hengist, Aaron
collection PubMed
description BACKGROUND: Continuous glucose monitors (CGMs) are being used to characterize postprandial glycemic responses and thereby provide personalized dietary advice to minimize glycemic excursions. However, the efficacy of such advice depends on reliable CGM responses. OBJECTIVE: To explore within-subject variability of CGM responses to duplicate meals in an inpatient setting. METHODS: CGM data were collected in two controlled feeding studies (NCT03407053 and NCT03878108) in 30 participants without diabetes capturing 948 meal responses in duplicate ~1 week apart from three dietary patterns. One study used two different CGMs (Abbott Freestyle Libre Pro and Dexcom G4 Platinum) whereas the other study used only Dexcom. We calculated the incremental area under the curve (iAUC) for each 2-h post-meal period and compared within-subject iAUCs using the same CGM for the duplicate meals using linear correlations, intra-class correlation coefficients (ICC), Bland-Altman analyses, and compared individual variability of glycemic responses to duplicate meals versus different meals using standard deviations (SDs). RESULTS: There were weak to moderate positive linear correlations between within-subject iAUCs for duplicate meals (Abbott r=0.47, p<0.0001, Dexcom r=0.40, p<0.0001), with low within-participant reliability indicated by ICC (Abbott 0.31, Dexcom 0.16). Bland-Altman analyses indicated wide limits of agreement (Abbott −31.4 to 31.5 mg/dL, Dexcom −32.3 to 31.6 mg/dL) but no significant bias of mean iAUCs for duplicate meals (Abbott 0.1 mg/dL, Dexcom −0.3 mg/dL). Individual variability of glycemic responses to duplicate meals was similar to that of different meals evaluated each diet week for both Abbott (SD(duplicate) = 10.7 mg/dL, SD(week 1) =12.4 mg/dL, SD(week 2) =11.6 mg/dL, p=0.38) and Dexcom (SD(duplicate) = 11.8 mg/dL, SD(week 1) =12.2 mg/dL, SD(week 2) =12.4 mg/dL, p=0.80). CONCLUSIONS: Individual postprandial CGM responses to duplicate meals were unreliable in adults without diabetes. Personalized diet advice based on CGM measurements in adults without diabetes requires more reliable methods involving aggregated repeated measurements.
format Online
Article
Text
id pubmed-10371100
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cold Spring Harbor Laboratory
record_format MEDLINE/PubMed
spelling pubmed-103711002023-07-27 Imprecision nutrition? Duplicate meals result in unreliable individual glycemic responses measured by continuous glucose monitors across three dietary patterns in adults without diabetes Hengist, Aaron Guo, Juen Hall, Kevin D medRxiv Article BACKGROUND: Continuous glucose monitors (CGMs) are being used to characterize postprandial glycemic responses and thereby provide personalized dietary advice to minimize glycemic excursions. However, the efficacy of such advice depends on reliable CGM responses. OBJECTIVE: To explore within-subject variability of CGM responses to duplicate meals in an inpatient setting. METHODS: CGM data were collected in two controlled feeding studies (NCT03407053 and NCT03878108) in 30 participants without diabetes capturing 948 meal responses in duplicate ~1 week apart from three dietary patterns. One study used two different CGMs (Abbott Freestyle Libre Pro and Dexcom G4 Platinum) whereas the other study used only Dexcom. We calculated the incremental area under the curve (iAUC) for each 2-h post-meal period and compared within-subject iAUCs using the same CGM for the duplicate meals using linear correlations, intra-class correlation coefficients (ICC), Bland-Altman analyses, and compared individual variability of glycemic responses to duplicate meals versus different meals using standard deviations (SDs). RESULTS: There were weak to moderate positive linear correlations between within-subject iAUCs for duplicate meals (Abbott r=0.47, p<0.0001, Dexcom r=0.40, p<0.0001), with low within-participant reliability indicated by ICC (Abbott 0.31, Dexcom 0.16). Bland-Altman analyses indicated wide limits of agreement (Abbott −31.4 to 31.5 mg/dL, Dexcom −32.3 to 31.6 mg/dL) but no significant bias of mean iAUCs for duplicate meals (Abbott 0.1 mg/dL, Dexcom −0.3 mg/dL). Individual variability of glycemic responses to duplicate meals was similar to that of different meals evaluated each diet week for both Abbott (SD(duplicate) = 10.7 mg/dL, SD(week 1) =12.4 mg/dL, SD(week 2) =11.6 mg/dL, p=0.38) and Dexcom (SD(duplicate) = 11.8 mg/dL, SD(week 1) =12.2 mg/dL, SD(week 2) =12.4 mg/dL, p=0.80). CONCLUSIONS: Individual postprandial CGM responses to duplicate meals were unreliable in adults without diabetes. Personalized diet advice based on CGM measurements in adults without diabetes requires more reliable methods involving aggregated repeated measurements. Cold Spring Harbor Laboratory 2023-06-15 /pmc/articles/PMC10371100/ /pubmed/37503002 http://dx.doi.org/10.1101/2023.06.14.23291406 Text en This article is a US Government work.
spellingShingle Article
Hengist, Aaron
Guo, Juen
Hall, Kevin D
Imprecision nutrition? Duplicate meals result in unreliable individual glycemic responses measured by continuous glucose monitors across three dietary patterns in adults without diabetes
title Imprecision nutrition? Duplicate meals result in unreliable individual glycemic responses measured by continuous glucose monitors across three dietary patterns in adults without diabetes
title_full Imprecision nutrition? Duplicate meals result in unreliable individual glycemic responses measured by continuous glucose monitors across three dietary patterns in adults without diabetes
title_fullStr Imprecision nutrition? Duplicate meals result in unreliable individual glycemic responses measured by continuous glucose monitors across three dietary patterns in adults without diabetes
title_full_unstemmed Imprecision nutrition? Duplicate meals result in unreliable individual glycemic responses measured by continuous glucose monitors across three dietary patterns in adults without diabetes
title_short Imprecision nutrition? Duplicate meals result in unreliable individual glycemic responses measured by continuous glucose monitors across three dietary patterns in adults without diabetes
title_sort imprecision nutrition? duplicate meals result in unreliable individual glycemic responses measured by continuous glucose monitors across three dietary patterns in adults without diabetes
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10371100/
https://www.ncbi.nlm.nih.gov/pubmed/37503002
http://dx.doi.org/10.1101/2023.06.14.23291406
work_keys_str_mv AT hengistaaron imprecisionnutritionduplicatemealsresultinunreliableindividualglycemicresponsesmeasuredbycontinuousglucosemonitorsacrossthreedietarypatternsinadultswithoutdiabetes
AT guojuen imprecisionnutritionduplicatemealsresultinunreliableindividualglycemicresponsesmeasuredbycontinuousglucosemonitorsacrossthreedietarypatternsinadultswithoutdiabetes
AT hallkevind imprecisionnutritionduplicatemealsresultinunreliableindividualglycemicresponsesmeasuredbycontinuousglucosemonitorsacrossthreedietarypatternsinadultswithoutdiabetes