Suture tie-down forces and cyclic contractile forces after undersized tricuspid annuloplasty using a Tri-Ad Adams tricuspid annuloplasty ring in an ovine model
OBJECTIVES: This study evaluated suture tie-down forces and cyclic contractile forces (CCFs) after undersized tricuspid annuloplasty using a hybrid band. METHODS: Downsized tricuspid annuloplasty was planned in adult male sheep using 8 force transducers attached from the septal to the anterior annul...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10371394/ https://www.ncbi.nlm.nih.gov/pubmed/37486243 http://dx.doi.org/10.1093/icvts/ivad121 |
_version_ | 1785078138024230912 |
---|---|
author | Cho, Sungkyu Park, Chan Hun Shin, Heean Lim, Jae Hong Sohn, Suk Ho Kim, Ji Seong Choi, Jae Woong Lee, Jung Chan Kim, Woong-Han Hwang, Ho Young |
author_facet | Cho, Sungkyu Park, Chan Hun Shin, Heean Lim, Jae Hong Sohn, Suk Ho Kim, Ji Seong Choi, Jae Woong Lee, Jung Chan Kim, Woong-Han Hwang, Ho Young |
author_sort | Cho, Sungkyu |
collection | PubMed |
description | OBJECTIVES: This study evaluated suture tie-down forces and cyclic contractile forces (CCFs) after undersized tricuspid annuloplasty using a hybrid band. METHODS: Downsized tricuspid annuloplasty was planned in adult male sheep using 8 force transducers attached from the septal to the anterior annular areas of the ring (segments 1 and 2, flexible septal; segments 3 and 4, semi-rigid posterior; segments 5 and 6, semi-rigid anterior; segments 7 and 8, flexible anterior). CCFs were analysed at 3 different levels of peak right ventricular pressure (RVP): 30, 50 and 70 mmHg. RESULTS: Eight 5-year-old male Corriedale sheep (average body weight = 66.8 kg) were used. The average suture tie-down force was 4.42 [standard deviation (SD): 2.32] N. When the forces were compared, it was lowest in the flexible anterior area and highest in the flexible septal area (P < 0.001). With the RVP of 30 mmHg, the average CCFs was lowest at segment 3 [0.07 (SD: 0.07) N] and highest at segment 7 [0.15 (SD: 0.08) N]. The CCFs were 0.12 (SD: 0.1) N, 0.09 (SD: 0.12) N, 0.14 (SD: 0.1) N and 0.13 (SD: 0.09) N in the flexible septal, semi-rigid posterior, semi-rigid anterior and flexible anterior parts, respectively (P = 0.208). As the peak RVP increased to 50 and 70 mmHg, the CCFs of each area increased significantly (P < 0.001). Despite this increase, the CCFs remained low (0.1 and 0.3 N), and differences in CCFs between segments and between annular areas showed similar patterns. CONCLUSIONS: The flexible end of the hybrid band reduces the CCFs and might prevent annular tears after ring tricuspid annuloplasty, and the risk of tear would be low even in the septal area. |
format | Online Article Text |
id | pubmed-10371394 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-103713942023-07-27 Suture tie-down forces and cyclic contractile forces after undersized tricuspid annuloplasty using a Tri-Ad Adams tricuspid annuloplasty ring in an ovine model Cho, Sungkyu Park, Chan Hun Shin, Heean Lim, Jae Hong Sohn, Suk Ho Kim, Ji Seong Choi, Jae Woong Lee, Jung Chan Kim, Woong-Han Hwang, Ho Young Interdiscip Cardiovasc Thorac Surg Valvular Heart Disease OBJECTIVES: This study evaluated suture tie-down forces and cyclic contractile forces (CCFs) after undersized tricuspid annuloplasty using a hybrid band. METHODS: Downsized tricuspid annuloplasty was planned in adult male sheep using 8 force transducers attached from the septal to the anterior annular areas of the ring (segments 1 and 2, flexible septal; segments 3 and 4, semi-rigid posterior; segments 5 and 6, semi-rigid anterior; segments 7 and 8, flexible anterior). CCFs were analysed at 3 different levels of peak right ventricular pressure (RVP): 30, 50 and 70 mmHg. RESULTS: Eight 5-year-old male Corriedale sheep (average body weight = 66.8 kg) were used. The average suture tie-down force was 4.42 [standard deviation (SD): 2.32] N. When the forces were compared, it was lowest in the flexible anterior area and highest in the flexible septal area (P < 0.001). With the RVP of 30 mmHg, the average CCFs was lowest at segment 3 [0.07 (SD: 0.07) N] and highest at segment 7 [0.15 (SD: 0.08) N]. The CCFs were 0.12 (SD: 0.1) N, 0.09 (SD: 0.12) N, 0.14 (SD: 0.1) N and 0.13 (SD: 0.09) N in the flexible septal, semi-rigid posterior, semi-rigid anterior and flexible anterior parts, respectively (P = 0.208). As the peak RVP increased to 50 and 70 mmHg, the CCFs of each area increased significantly (P < 0.001). Despite this increase, the CCFs remained low (0.1 and 0.3 N), and differences in CCFs between segments and between annular areas showed similar patterns. CONCLUSIONS: The flexible end of the hybrid band reduces the CCFs and might prevent annular tears after ring tricuspid annuloplasty, and the risk of tear would be low even in the septal area. Oxford University Press 2023-07-24 /pmc/articles/PMC10371394/ /pubmed/37486243 http://dx.doi.org/10.1093/icvts/ivad121 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Valvular Heart Disease Cho, Sungkyu Park, Chan Hun Shin, Heean Lim, Jae Hong Sohn, Suk Ho Kim, Ji Seong Choi, Jae Woong Lee, Jung Chan Kim, Woong-Han Hwang, Ho Young Suture tie-down forces and cyclic contractile forces after undersized tricuspid annuloplasty using a Tri-Ad Adams tricuspid annuloplasty ring in an ovine model |
title | Suture tie-down forces and cyclic contractile forces after undersized tricuspid annuloplasty using a Tri-Ad Adams tricuspid annuloplasty ring in an ovine model |
title_full | Suture tie-down forces and cyclic contractile forces after undersized tricuspid annuloplasty using a Tri-Ad Adams tricuspid annuloplasty ring in an ovine model |
title_fullStr | Suture tie-down forces and cyclic contractile forces after undersized tricuspid annuloplasty using a Tri-Ad Adams tricuspid annuloplasty ring in an ovine model |
title_full_unstemmed | Suture tie-down forces and cyclic contractile forces after undersized tricuspid annuloplasty using a Tri-Ad Adams tricuspid annuloplasty ring in an ovine model |
title_short | Suture tie-down forces and cyclic contractile forces after undersized tricuspid annuloplasty using a Tri-Ad Adams tricuspid annuloplasty ring in an ovine model |
title_sort | suture tie-down forces and cyclic contractile forces after undersized tricuspid annuloplasty using a tri-ad adams tricuspid annuloplasty ring in an ovine model |
topic | Valvular Heart Disease |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10371394/ https://www.ncbi.nlm.nih.gov/pubmed/37486243 http://dx.doi.org/10.1093/icvts/ivad121 |
work_keys_str_mv | AT chosungkyu suturetiedownforcesandcycliccontractileforcesafterundersizedtricuspidannuloplastyusingatriadadamstricuspidannuloplastyringinanovinemodel AT parkchanhun suturetiedownforcesandcycliccontractileforcesafterundersizedtricuspidannuloplastyusingatriadadamstricuspidannuloplastyringinanovinemodel AT shinheean suturetiedownforcesandcycliccontractileforcesafterundersizedtricuspidannuloplastyusingatriadadamstricuspidannuloplastyringinanovinemodel AT limjaehong suturetiedownforcesandcycliccontractileforcesafterundersizedtricuspidannuloplastyusingatriadadamstricuspidannuloplastyringinanovinemodel AT sohnsukho suturetiedownforcesandcycliccontractileforcesafterundersizedtricuspidannuloplastyusingatriadadamstricuspidannuloplastyringinanovinemodel AT kimjiseong suturetiedownforcesandcycliccontractileforcesafterundersizedtricuspidannuloplastyusingatriadadamstricuspidannuloplastyringinanovinemodel AT choijaewoong suturetiedownforcesandcycliccontractileforcesafterundersizedtricuspidannuloplastyusingatriadadamstricuspidannuloplastyringinanovinemodel AT leejungchan suturetiedownforcesandcycliccontractileforcesafterundersizedtricuspidannuloplastyusingatriadadamstricuspidannuloplastyringinanovinemodel AT kimwoonghan suturetiedownforcesandcycliccontractileforcesafterundersizedtricuspidannuloplastyusingatriadadamstricuspidannuloplastyringinanovinemodel AT hwanghoyoung suturetiedownforcesandcycliccontractileforcesafterundersizedtricuspidannuloplastyusingatriadadamstricuspidannuloplastyringinanovinemodel |