Cargando…

Transversalis fascia suture reinforcement may facilitate the performance of electrospun P(LLA-CL) nanoscale fibrinogen mesh in inguinal hernia repair: a prospective single-center cohort study

The aim of this study was to evaluate a new electrospun P(LLA-CL) nanoscale fibrinogen mesh performance in real-world clinical practice. A prospective, single-center evaluation of Lichtenstein inguinal hernia repair using electrospun P(LLA-CL) nanoscale fibrinogen mesh in elderly patients with comor...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Kewei, Zhu, Leiming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10372066/
https://www.ncbi.nlm.nih.gov/pubmed/37495644
http://dx.doi.org/10.1038/s41598-023-39391-0
_version_ 1785078287991570432
author Zhang, Kewei
Zhu, Leiming
author_facet Zhang, Kewei
Zhu, Leiming
author_sort Zhang, Kewei
collection PubMed
description The aim of this study was to evaluate a new electrospun P(LLA-CL) nanoscale fibrinogen mesh performance in real-world clinical practice. A prospective, single-center evaluation of Lichtenstein inguinal hernia repair using electrospun P(LLA-CL) nanoscale fibrinogen mesh in elderly patients with comorbid diseases was conducted between 2020 and 2022. A suture reinforcement of transversalis fascia was applied before mesh implantation. Hernia recurrence, pain score and overall complication rate were measured. A total of 52 inguinal hernias in 48 patients were included. The age of patients ranged from 33 to 95 years, with a median of 78 years. Comorbid conditions included cardiopulmonary disease, organ dysfunction, anticoagulant use, diabetes and smoking. By optimizing the physical condition perioperatively, all patients finished treatment successfully. Four cases recurred secondary to direct hernias or combined hernias and were diagnosed in the first 24 case cohort during follow-up. With surgical procedural modification involving strengthening the posterior inguinal floor by reef-up suturing of the transversalis fascia and the inferior edge of mesh slit to accommodate the spermatic cord, no further recurrence was diagnosed. Postoperative pain was mild and the pain score decreased three months after surgery compared to 1 week after surgery (p = 0.0099). No severe complications occurred, while seroma occurred in six cases. Electrospun P(LLA-CL) nanoscale fibrinogen mesh is safe and effective in repairing inguinal hernias in elderly patients with comorbid disease. A strengthening of the transversalis fascia by suturing may enhance the performance of this mesh.
format Online
Article
Text
id pubmed-10372066
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-103720662023-07-28 Transversalis fascia suture reinforcement may facilitate the performance of electrospun P(LLA-CL) nanoscale fibrinogen mesh in inguinal hernia repair: a prospective single-center cohort study Zhang, Kewei Zhu, Leiming Sci Rep Article The aim of this study was to evaluate a new electrospun P(LLA-CL) nanoscale fibrinogen mesh performance in real-world clinical practice. A prospective, single-center evaluation of Lichtenstein inguinal hernia repair using electrospun P(LLA-CL) nanoscale fibrinogen mesh in elderly patients with comorbid diseases was conducted between 2020 and 2022. A suture reinforcement of transversalis fascia was applied before mesh implantation. Hernia recurrence, pain score and overall complication rate were measured. A total of 52 inguinal hernias in 48 patients were included. The age of patients ranged from 33 to 95 years, with a median of 78 years. Comorbid conditions included cardiopulmonary disease, organ dysfunction, anticoagulant use, diabetes and smoking. By optimizing the physical condition perioperatively, all patients finished treatment successfully. Four cases recurred secondary to direct hernias or combined hernias and were diagnosed in the first 24 case cohort during follow-up. With surgical procedural modification involving strengthening the posterior inguinal floor by reef-up suturing of the transversalis fascia and the inferior edge of mesh slit to accommodate the spermatic cord, no further recurrence was diagnosed. Postoperative pain was mild and the pain score decreased three months after surgery compared to 1 week after surgery (p = 0.0099). No severe complications occurred, while seroma occurred in six cases. Electrospun P(LLA-CL) nanoscale fibrinogen mesh is safe and effective in repairing inguinal hernias in elderly patients with comorbid disease. A strengthening of the transversalis fascia by suturing may enhance the performance of this mesh. Nature Publishing Group UK 2023-07-26 /pmc/articles/PMC10372066/ /pubmed/37495644 http://dx.doi.org/10.1038/s41598-023-39391-0 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Zhang, Kewei
Zhu, Leiming
Transversalis fascia suture reinforcement may facilitate the performance of electrospun P(LLA-CL) nanoscale fibrinogen mesh in inguinal hernia repair: a prospective single-center cohort study
title Transversalis fascia suture reinforcement may facilitate the performance of electrospun P(LLA-CL) nanoscale fibrinogen mesh in inguinal hernia repair: a prospective single-center cohort study
title_full Transversalis fascia suture reinforcement may facilitate the performance of electrospun P(LLA-CL) nanoscale fibrinogen mesh in inguinal hernia repair: a prospective single-center cohort study
title_fullStr Transversalis fascia suture reinforcement may facilitate the performance of electrospun P(LLA-CL) nanoscale fibrinogen mesh in inguinal hernia repair: a prospective single-center cohort study
title_full_unstemmed Transversalis fascia suture reinforcement may facilitate the performance of electrospun P(LLA-CL) nanoscale fibrinogen mesh in inguinal hernia repair: a prospective single-center cohort study
title_short Transversalis fascia suture reinforcement may facilitate the performance of electrospun P(LLA-CL) nanoscale fibrinogen mesh in inguinal hernia repair: a prospective single-center cohort study
title_sort transversalis fascia suture reinforcement may facilitate the performance of electrospun p(lla-cl) nanoscale fibrinogen mesh in inguinal hernia repair: a prospective single-center cohort study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10372066/
https://www.ncbi.nlm.nih.gov/pubmed/37495644
http://dx.doi.org/10.1038/s41598-023-39391-0
work_keys_str_mv AT zhangkewei transversalisfasciasuturereinforcementmayfacilitatetheperformanceofelectrospunpllaclnanoscalefibrinogenmeshininguinalherniarepairaprospectivesinglecentercohortstudy
AT zhuleiming transversalisfasciasuturereinforcementmayfacilitatetheperformanceofelectrospunpllaclnanoscalefibrinogenmeshininguinalherniarepairaprospectivesinglecentercohortstudy