Analytical performance of the digital morphology analyzer Sysmex DI-60 for body fluid cell differential counts

BACKGROUND: Sysmex DI-60 (Sysmex, Kobe, Japan) is a digital morphology (DM) analyzer widely used in clinical laboratories and supports body fluid (BF) applications. We evaluated analytical performance of DI-60 compared with XN-350 (Sysmex) and manual counting for BF cell differential counts. METHODS...

Descripción completa

Detalles Bibliográficos
Autores principales: Yoon, Sumi, Kim, Hye Ryoun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10374087/
https://www.ncbi.nlm.nih.gov/pubmed/37498851
http://dx.doi.org/10.1371/journal.pone.0288551
_version_ 1785078700121784320
author Yoon, Sumi
Kim, Hye Ryoun
author_facet Yoon, Sumi
Kim, Hye Ryoun
author_sort Yoon, Sumi
collection PubMed
description BACKGROUND: Sysmex DI-60 (Sysmex, Kobe, Japan) is a digital morphology (DM) analyzer widely used in clinical laboratories and supports body fluid (BF) applications. We evaluated analytical performance of DI-60 compared with XN-350 (Sysmex) and manual counting for BF cell differential counts. METHODS: A total of 213 BF samples were collected (47 cerebrospinal fluid [CSF], 80 pleural fluid, and 86 ascites samples). The analytical performance of DI-60 for BF cell differential counts was evaluated based on sensitivity, specificity, accuracy, and agreement. BF cell differential counts obtained by DI-60 were compared with those obtained by XN-350 and manual counting. RESULTS: The overall sensitivity was high for neutrophils, lymphocytes, and macrophages (range, 83.1–99.4%). The overall specificity and overall accuracy were high for all cell types (range, 95.3–99.7% and 94.3–99.3%, respectively). The agreement between DI-60 pre-classification and verification was strong (κ = 0.89). The absolute mean differences between DI-60 verification and XN-350 ranged from 0.26 to 11.05, and differences between DI-60 verification and manual counting ranged from 0.01 to 4.76. CONCLUSIONS: This is the first study to evaluate the performance of DI-60 compared with XN-350 and manual counting for BF cell differential counts. DI-60 showed reliable performance with CSF, pleural fluid, and ascites samples. For BF cell differential counts, DI-60 may be a better option than XN-350 and could be used for screening purposes in understaffed laboratories. To improve the hematology workflow for BF cell differential counting, the DM analyzer needs to be optimized by taking into account the laboratory situation and unmet needs, and the clinical laboratory needs to establish criteria for verification and manual slide review.
format Online
Article
Text
id pubmed-10374087
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-103740872023-07-28 Analytical performance of the digital morphology analyzer Sysmex DI-60 for body fluid cell differential counts Yoon, Sumi Kim, Hye Ryoun PLoS One Research Article BACKGROUND: Sysmex DI-60 (Sysmex, Kobe, Japan) is a digital morphology (DM) analyzer widely used in clinical laboratories and supports body fluid (BF) applications. We evaluated analytical performance of DI-60 compared with XN-350 (Sysmex) and manual counting for BF cell differential counts. METHODS: A total of 213 BF samples were collected (47 cerebrospinal fluid [CSF], 80 pleural fluid, and 86 ascites samples). The analytical performance of DI-60 for BF cell differential counts was evaluated based on sensitivity, specificity, accuracy, and agreement. BF cell differential counts obtained by DI-60 were compared with those obtained by XN-350 and manual counting. RESULTS: The overall sensitivity was high for neutrophils, lymphocytes, and macrophages (range, 83.1–99.4%). The overall specificity and overall accuracy were high for all cell types (range, 95.3–99.7% and 94.3–99.3%, respectively). The agreement between DI-60 pre-classification and verification was strong (κ = 0.89). The absolute mean differences between DI-60 verification and XN-350 ranged from 0.26 to 11.05, and differences between DI-60 verification and manual counting ranged from 0.01 to 4.76. CONCLUSIONS: This is the first study to evaluate the performance of DI-60 compared with XN-350 and manual counting for BF cell differential counts. DI-60 showed reliable performance with CSF, pleural fluid, and ascites samples. For BF cell differential counts, DI-60 may be a better option than XN-350 and could be used for screening purposes in understaffed laboratories. To improve the hematology workflow for BF cell differential counting, the DM analyzer needs to be optimized by taking into account the laboratory situation and unmet needs, and the clinical laboratory needs to establish criteria for verification and manual slide review. Public Library of Science 2023-07-27 /pmc/articles/PMC10374087/ /pubmed/37498851 http://dx.doi.org/10.1371/journal.pone.0288551 Text en © 2023 Yoon, Kim https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Yoon, Sumi
Kim, Hye Ryoun
Analytical performance of the digital morphology analyzer Sysmex DI-60 for body fluid cell differential counts
title Analytical performance of the digital morphology analyzer Sysmex DI-60 for body fluid cell differential counts
title_full Analytical performance of the digital morphology analyzer Sysmex DI-60 for body fluid cell differential counts
title_fullStr Analytical performance of the digital morphology analyzer Sysmex DI-60 for body fluid cell differential counts
title_full_unstemmed Analytical performance of the digital morphology analyzer Sysmex DI-60 for body fluid cell differential counts
title_short Analytical performance of the digital morphology analyzer Sysmex DI-60 for body fluid cell differential counts
title_sort analytical performance of the digital morphology analyzer sysmex di-60 for body fluid cell differential counts
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10374087/
https://www.ncbi.nlm.nih.gov/pubmed/37498851
http://dx.doi.org/10.1371/journal.pone.0288551
work_keys_str_mv AT yoonsumi analyticalperformanceofthedigitalmorphologyanalyzersysmexdi60forbodyfluidcelldifferentialcounts
AT kimhyeryoun analyticalperformanceofthedigitalmorphologyanalyzersysmexdi60forbodyfluidcelldifferentialcounts