Cargando…
Combining the advantages of 3-D and 2-D templating of total hip arthroplasty using a new tin-filtered ultra-low-dose CT of the hip with comparable radiation dose to conventional radiographs
BACKGROUND: Inaccurately scaled radiographs for total hip arthroplasty (THA) templating are a source of error not recognizable to the surgeon and may lead to inaccurate reconstruction and thus revision surgery or litigation. Planning based on computed tomography (CT) scans is more accurate but assoc...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10374735/ https://www.ncbi.nlm.nih.gov/pubmed/36460762 http://dx.doi.org/10.1007/s00402-022-04697-7 |
_version_ | 1785078840345755648 |
---|---|
author | Kaiser, Dominik Hoch, Armando Rahm, Stefan Stern, Christoph Sutter, Reto Zingg, Patrick O. |
author_facet | Kaiser, Dominik Hoch, Armando Rahm, Stefan Stern, Christoph Sutter, Reto Zingg, Patrick O. |
author_sort | Kaiser, Dominik |
collection | PubMed |
description | BACKGROUND: Inaccurately scaled radiographs for total hip arthroplasty (THA) templating are a source of error not recognizable to the surgeon and may lead to inaccurate reconstruction and thus revision surgery or litigation. Planning based on computed tomography (CT) scans is more accurate but associated with higher radiation exposure. The aim of this study was (1) to retrospectively assess the scaling deviation of pelvic radiographs; (2) to prospectively assess the feasibility and the radiation dose of THA templating on radiograph-like images reconstructed from a tin-filtered ultra-low-dose CT dataset. METHODS: 120 consecutive patients were retrospectively analyzed to assess the magnification error of our current THA templates. 27 consecutive patients were prospectively enrolled and a radiographic work-up in the supine position including a new tin-filtered ultra-low-dose CT scan protocol was obtained. THA was templated on both images. Radiation dose was calculated. RESULTS: Scaling deviations between preoperative radiographs and CT of ≥ 5% were seen in 25% of the 120 retrospectively analyzed patients. Between the two templates trochanter tip distance differed significantly (Δ2.4 mm, 0–7 mm, p = 0.035)), predicted femoral shaft size/cup size was the same in 45%/41%. The radiation dose of the CT (0.58 mSv, range 0.53–0.64) was remarkably low. CONCLUSION: Scaling deviations of pelvic radiographs for templating THA may lead to planning errors of ≥ 3 mm in 25% and ≥ 6 mm in 2% of the patients. 2-D templating on radiograph-like images based on tin-filtered ultra-low-dose CT eliminates this source of error without increased radiation dose. LEVEL OF EVIDENCE: Retrospective and prospective comparative study, Level III. |
format | Online Article Text |
id | pubmed-10374735 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-103747352023-07-29 Combining the advantages of 3-D and 2-D templating of total hip arthroplasty using a new tin-filtered ultra-low-dose CT of the hip with comparable radiation dose to conventional radiographs Kaiser, Dominik Hoch, Armando Rahm, Stefan Stern, Christoph Sutter, Reto Zingg, Patrick O. Arch Orthop Trauma Surg Hip Arthroplasty BACKGROUND: Inaccurately scaled radiographs for total hip arthroplasty (THA) templating are a source of error not recognizable to the surgeon and may lead to inaccurate reconstruction and thus revision surgery or litigation. Planning based on computed tomography (CT) scans is more accurate but associated with higher radiation exposure. The aim of this study was (1) to retrospectively assess the scaling deviation of pelvic radiographs; (2) to prospectively assess the feasibility and the radiation dose of THA templating on radiograph-like images reconstructed from a tin-filtered ultra-low-dose CT dataset. METHODS: 120 consecutive patients were retrospectively analyzed to assess the magnification error of our current THA templates. 27 consecutive patients were prospectively enrolled and a radiographic work-up in the supine position including a new tin-filtered ultra-low-dose CT scan protocol was obtained. THA was templated on both images. Radiation dose was calculated. RESULTS: Scaling deviations between preoperative radiographs and CT of ≥ 5% were seen in 25% of the 120 retrospectively analyzed patients. Between the two templates trochanter tip distance differed significantly (Δ2.4 mm, 0–7 mm, p = 0.035)), predicted femoral shaft size/cup size was the same in 45%/41%. The radiation dose of the CT (0.58 mSv, range 0.53–0.64) was remarkably low. CONCLUSION: Scaling deviations of pelvic radiographs for templating THA may lead to planning errors of ≥ 3 mm in 25% and ≥ 6 mm in 2% of the patients. 2-D templating on radiograph-like images based on tin-filtered ultra-low-dose CT eliminates this source of error without increased radiation dose. LEVEL OF EVIDENCE: Retrospective and prospective comparative study, Level III. Springer Berlin Heidelberg 2022-12-03 2023 /pmc/articles/PMC10374735/ /pubmed/36460762 http://dx.doi.org/10.1007/s00402-022-04697-7 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Hip Arthroplasty Kaiser, Dominik Hoch, Armando Rahm, Stefan Stern, Christoph Sutter, Reto Zingg, Patrick O. Combining the advantages of 3-D and 2-D templating of total hip arthroplasty using a new tin-filtered ultra-low-dose CT of the hip with comparable radiation dose to conventional radiographs |
title | Combining the advantages of 3-D and 2-D templating of total hip arthroplasty using a new tin-filtered ultra-low-dose CT of the hip with comparable radiation dose to conventional radiographs |
title_full | Combining the advantages of 3-D and 2-D templating of total hip arthroplasty using a new tin-filtered ultra-low-dose CT of the hip with comparable radiation dose to conventional radiographs |
title_fullStr | Combining the advantages of 3-D and 2-D templating of total hip arthroplasty using a new tin-filtered ultra-low-dose CT of the hip with comparable radiation dose to conventional radiographs |
title_full_unstemmed | Combining the advantages of 3-D and 2-D templating of total hip arthroplasty using a new tin-filtered ultra-low-dose CT of the hip with comparable radiation dose to conventional radiographs |
title_short | Combining the advantages of 3-D and 2-D templating of total hip arthroplasty using a new tin-filtered ultra-low-dose CT of the hip with comparable radiation dose to conventional radiographs |
title_sort | combining the advantages of 3-d and 2-d templating of total hip arthroplasty using a new tin-filtered ultra-low-dose ct of the hip with comparable radiation dose to conventional radiographs |
topic | Hip Arthroplasty |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10374735/ https://www.ncbi.nlm.nih.gov/pubmed/36460762 http://dx.doi.org/10.1007/s00402-022-04697-7 |
work_keys_str_mv | AT kaiserdominik combiningtheadvantagesof3dand2dtemplatingoftotalhiparthroplastyusinganewtinfilteredultralowdosectofthehipwithcomparableradiationdosetoconventionalradiographs AT hocharmando combiningtheadvantagesof3dand2dtemplatingoftotalhiparthroplastyusinganewtinfilteredultralowdosectofthehipwithcomparableradiationdosetoconventionalradiographs AT rahmstefan combiningtheadvantagesof3dand2dtemplatingoftotalhiparthroplastyusinganewtinfilteredultralowdosectofthehipwithcomparableradiationdosetoconventionalradiographs AT sternchristoph combiningtheadvantagesof3dand2dtemplatingoftotalhiparthroplastyusinganewtinfilteredultralowdosectofthehipwithcomparableradiationdosetoconventionalradiographs AT sutterreto combiningtheadvantagesof3dand2dtemplatingoftotalhiparthroplastyusinganewtinfilteredultralowdosectofthehipwithcomparableradiationdosetoconventionalradiographs AT zinggpatricko combiningtheadvantagesof3dand2dtemplatingoftotalhiparthroplastyusinganewtinfilteredultralowdosectofthehipwithcomparableradiationdosetoconventionalradiographs |