Cargando…
Whole body irradiation with intensity-modulated helical tomotherapy prior to haematopoietic stem cell transplantation: analysis of organs at risk by dose and its effect on blood kinetics
BACKGROUND: Intensity-modulated helical tomotherapy (HT) is a promising technique in preparation for bone marrow transplantation. Nevertheless, radiation-sensitive organs can be substantially compromised due to suboptimal delivery techniques of total body irradiation (TBI). To reduce the potential b...
Autores principales: | , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10374741/ https://www.ncbi.nlm.nih.gov/pubmed/36856852 http://dx.doi.org/10.1007/s00432-023-04657-7 |
_version_ | 1785078841336659968 |
---|---|
author | Köksal, Mümtaz Baumert, Jonathan Jazmati, Danny Schoroth, Felix Garbe, Stephan Koch, David Scafa, Davide Sarria, Gustavo R. Leitzen, Christina Massoth, Gregor Delis, Achilles Heine, Annkristin Holderried, Tobias Brossart, Peter Müdder, Thomas Schmeel, Leonard C. |
author_facet | Köksal, Mümtaz Baumert, Jonathan Jazmati, Danny Schoroth, Felix Garbe, Stephan Koch, David Scafa, Davide Sarria, Gustavo R. Leitzen, Christina Massoth, Gregor Delis, Achilles Heine, Annkristin Holderried, Tobias Brossart, Peter Müdder, Thomas Schmeel, Leonard C. |
author_sort | Köksal, Mümtaz |
collection | PubMed |
description | BACKGROUND: Intensity-modulated helical tomotherapy (HT) is a promising technique in preparation for bone marrow transplantation. Nevertheless, radiation-sensitive organs can be substantially compromised due to suboptimal delivery techniques of total body irradiation (TBI). To reduce the potential burden of radiation toxicity to organs at risk (OAR), high-quality coverage and homogeneity are essential. We investigated dosimetric data from kidney, lung and thorax, liver, and spleen in relation to peripheral blood kinetics. To further advance intensity-modulated total body irradiation (TBI), the potential for dose reduction to lung and kidney was considered in the analysis. PATIENTS AND METHODS: 46 patients undergoing TBI were included in this analysis, partially divided into dose groups (2, 4, 8, and 12 Gy). HT was performed using a rotating gantry to ensuring optimal reduction of radiation to the lungs and kidneys and to provide optimal coverage of other OAR. Common dosimetric parameters, such as D05, D95, and D50, were calculated and analysed. Leukocytes, neutrophils, platelets, creatinine, GFR, haemoglobin, overall survival, and graft-versus-host disease were related to the dosimetric evaluation using statistical tests. RESULTS: The mean D95 of the lung is 48.23%, less than half the prescribed and unreduced dose. The D95 of the chest is almost twice as high at 84.95%. Overall liver coverage values ranged from 96.79% for D95 to 107% for D05. The average dose sparing of all patients analysed resulted in an average D95 of 68.64% in the right kidney and 69.31% in the left kidney. Average D95 in the spleen was 94.28% and D05 was 107.05%. Homogeneity indexes ranged from 1.12 for liver to 2.28 for lung. The additional significance analyses conducted on these blood kinetics showed a significant difference between the 2 Gray group and the other three groups for leukocyte counts. Further statistical comparisons of the dose groups showed no significant differences. However, there were significant changes in the dose of OAR prescribed with dose sparing (e.g., lung vs. rib and kidney). CONCLUSION: Using intensity-modulated helical tomotherapy to deliver TBI is a feasible method in preparation for haematopoietic stem cell transplantation. Significant dose sparing in radiosensitive organs such as the lungs and kidneys is achievable with good overall quality of coverage. Peripheral blood kinetics support the positive impact of HT and its advantages strongly encourage its implementation within clinical routine. |
format | Online Article Text |
id | pubmed-10374741 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-103747412023-07-29 Whole body irradiation with intensity-modulated helical tomotherapy prior to haematopoietic stem cell transplantation: analysis of organs at risk by dose and its effect on blood kinetics Köksal, Mümtaz Baumert, Jonathan Jazmati, Danny Schoroth, Felix Garbe, Stephan Koch, David Scafa, Davide Sarria, Gustavo R. Leitzen, Christina Massoth, Gregor Delis, Achilles Heine, Annkristin Holderried, Tobias Brossart, Peter Müdder, Thomas Schmeel, Leonard C. J Cancer Res Clin Oncol Research BACKGROUND: Intensity-modulated helical tomotherapy (HT) is a promising technique in preparation for bone marrow transplantation. Nevertheless, radiation-sensitive organs can be substantially compromised due to suboptimal delivery techniques of total body irradiation (TBI). To reduce the potential burden of radiation toxicity to organs at risk (OAR), high-quality coverage and homogeneity are essential. We investigated dosimetric data from kidney, lung and thorax, liver, and spleen in relation to peripheral blood kinetics. To further advance intensity-modulated total body irradiation (TBI), the potential for dose reduction to lung and kidney was considered in the analysis. PATIENTS AND METHODS: 46 patients undergoing TBI were included in this analysis, partially divided into dose groups (2, 4, 8, and 12 Gy). HT was performed using a rotating gantry to ensuring optimal reduction of radiation to the lungs and kidneys and to provide optimal coverage of other OAR. Common dosimetric parameters, such as D05, D95, and D50, were calculated and analysed. Leukocytes, neutrophils, platelets, creatinine, GFR, haemoglobin, overall survival, and graft-versus-host disease were related to the dosimetric evaluation using statistical tests. RESULTS: The mean D95 of the lung is 48.23%, less than half the prescribed and unreduced dose. The D95 of the chest is almost twice as high at 84.95%. Overall liver coverage values ranged from 96.79% for D95 to 107% for D05. The average dose sparing of all patients analysed resulted in an average D95 of 68.64% in the right kidney and 69.31% in the left kidney. Average D95 in the spleen was 94.28% and D05 was 107.05%. Homogeneity indexes ranged from 1.12 for liver to 2.28 for lung. The additional significance analyses conducted on these blood kinetics showed a significant difference between the 2 Gray group and the other three groups for leukocyte counts. Further statistical comparisons of the dose groups showed no significant differences. However, there were significant changes in the dose of OAR prescribed with dose sparing (e.g., lung vs. rib and kidney). CONCLUSION: Using intensity-modulated helical tomotherapy to deliver TBI is a feasible method in preparation for haematopoietic stem cell transplantation. Significant dose sparing in radiosensitive organs such as the lungs and kidneys is achievable with good overall quality of coverage. Peripheral blood kinetics support the positive impact of HT and its advantages strongly encourage its implementation within clinical routine. Springer Berlin Heidelberg 2023-03-01 2023 /pmc/articles/PMC10374741/ /pubmed/36856852 http://dx.doi.org/10.1007/s00432-023-04657-7 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Research Köksal, Mümtaz Baumert, Jonathan Jazmati, Danny Schoroth, Felix Garbe, Stephan Koch, David Scafa, Davide Sarria, Gustavo R. Leitzen, Christina Massoth, Gregor Delis, Achilles Heine, Annkristin Holderried, Tobias Brossart, Peter Müdder, Thomas Schmeel, Leonard C. Whole body irradiation with intensity-modulated helical tomotherapy prior to haematopoietic stem cell transplantation: analysis of organs at risk by dose and its effect on blood kinetics |
title | Whole body irradiation with intensity-modulated helical tomotherapy prior to haematopoietic stem cell transplantation: analysis of organs at risk by dose and its effect on blood kinetics |
title_full | Whole body irradiation with intensity-modulated helical tomotherapy prior to haematopoietic stem cell transplantation: analysis of organs at risk by dose and its effect on blood kinetics |
title_fullStr | Whole body irradiation with intensity-modulated helical tomotherapy prior to haematopoietic stem cell transplantation: analysis of organs at risk by dose and its effect on blood kinetics |
title_full_unstemmed | Whole body irradiation with intensity-modulated helical tomotherapy prior to haematopoietic stem cell transplantation: analysis of organs at risk by dose and its effect on blood kinetics |
title_short | Whole body irradiation with intensity-modulated helical tomotherapy prior to haematopoietic stem cell transplantation: analysis of organs at risk by dose and its effect on blood kinetics |
title_sort | whole body irradiation with intensity-modulated helical tomotherapy prior to haematopoietic stem cell transplantation: analysis of organs at risk by dose and its effect on blood kinetics |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10374741/ https://www.ncbi.nlm.nih.gov/pubmed/36856852 http://dx.doi.org/10.1007/s00432-023-04657-7 |
work_keys_str_mv | AT koksalmumtaz wholebodyirradiationwithintensitymodulatedhelicaltomotherapypriortohaematopoieticstemcelltransplantationanalysisoforgansatriskbydoseanditseffectonbloodkinetics AT baumertjonathan wholebodyirradiationwithintensitymodulatedhelicaltomotherapypriortohaematopoieticstemcelltransplantationanalysisoforgansatriskbydoseanditseffectonbloodkinetics AT jazmatidanny wholebodyirradiationwithintensitymodulatedhelicaltomotherapypriortohaematopoieticstemcelltransplantationanalysisoforgansatriskbydoseanditseffectonbloodkinetics AT schorothfelix wholebodyirradiationwithintensitymodulatedhelicaltomotherapypriortohaematopoieticstemcelltransplantationanalysisoforgansatriskbydoseanditseffectonbloodkinetics AT garbestephan wholebodyirradiationwithintensitymodulatedhelicaltomotherapypriortohaematopoieticstemcelltransplantationanalysisoforgansatriskbydoseanditseffectonbloodkinetics AT kochdavid wholebodyirradiationwithintensitymodulatedhelicaltomotherapypriortohaematopoieticstemcelltransplantationanalysisoforgansatriskbydoseanditseffectonbloodkinetics AT scafadavide wholebodyirradiationwithintensitymodulatedhelicaltomotherapypriortohaematopoieticstemcelltransplantationanalysisoforgansatriskbydoseanditseffectonbloodkinetics AT sarriagustavor wholebodyirradiationwithintensitymodulatedhelicaltomotherapypriortohaematopoieticstemcelltransplantationanalysisoforgansatriskbydoseanditseffectonbloodkinetics AT leitzenchristina wholebodyirradiationwithintensitymodulatedhelicaltomotherapypriortohaematopoieticstemcelltransplantationanalysisoforgansatriskbydoseanditseffectonbloodkinetics AT massothgregor wholebodyirradiationwithintensitymodulatedhelicaltomotherapypriortohaematopoieticstemcelltransplantationanalysisoforgansatriskbydoseanditseffectonbloodkinetics AT delisachilles wholebodyirradiationwithintensitymodulatedhelicaltomotherapypriortohaematopoieticstemcelltransplantationanalysisoforgansatriskbydoseanditseffectonbloodkinetics AT heineannkristin wholebodyirradiationwithintensitymodulatedhelicaltomotherapypriortohaematopoieticstemcelltransplantationanalysisoforgansatriskbydoseanditseffectonbloodkinetics AT holderriedtobias wholebodyirradiationwithintensitymodulatedhelicaltomotherapypriortohaematopoieticstemcelltransplantationanalysisoforgansatriskbydoseanditseffectonbloodkinetics AT brossartpeter wholebodyirradiationwithintensitymodulatedhelicaltomotherapypriortohaematopoieticstemcelltransplantationanalysisoforgansatriskbydoseanditseffectonbloodkinetics AT mudderthomas wholebodyirradiationwithintensitymodulatedhelicaltomotherapypriortohaematopoieticstemcelltransplantationanalysisoforgansatriskbydoseanditseffectonbloodkinetics AT schmeelleonardc wholebodyirradiationwithintensitymodulatedhelicaltomotherapypriortohaematopoieticstemcelltransplantationanalysisoforgansatriskbydoseanditseffectonbloodkinetics |