Cargando…
Imprecise prediction of implant sizes with preoperative 2D digital templating in total knee arthroplasty
PURPOSE: To analyze the match between preoperatively determined implant size (2D templating) and intraoperatively used implant size in total knee arthroplasty (TKA). Also examined were the factors that might influence templating accuracy (gender, surgeon experience, obesity, etc.). MATERIALS AND MET...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10374828/ https://www.ncbi.nlm.nih.gov/pubmed/36648539 http://dx.doi.org/10.1007/s00402-023-04772-7 |
_version_ | 1785078861857292288 |
---|---|
author | Riechelmann, Felix Lettner, H. Mayr, R. Tandogan, R. Dammerer, D. Liebensteiner, M. |
author_facet | Riechelmann, Felix Lettner, H. Mayr, R. Tandogan, R. Dammerer, D. Liebensteiner, M. |
author_sort | Riechelmann, Felix |
collection | PubMed |
description | PURPOSE: To analyze the match between preoperatively determined implant size (2D templating) and intraoperatively used implant size in total knee arthroplasty (TKA). Also examined were the factors that might influence templating accuracy (gender, surgeon experience, obesity, etc.). MATERIALS AND METHODS: The study was retrospective and conducted in a specialized ENDOCERT arthroplasty center. Digital templating was done with the MediCAD software. If the planned and implanted TKA components (both femur and tibia) were the same size, the match was classified “exact.” A deviation of ± one size (at the femur or tibia or both) was classified “accurate.” A deviation of ± two or more sizes (at the femur or tibia or both) was classified “inaccurate.” Obesity, gender, implant type and surgeon experience were investigated for potential influence on templating accuracy. Chi-square tests and Cohen’s weighted kappa test were used for statistical analysis. RESULTS: A total of 482 cases [33.6% male, 66.4% female, age 69 ± 11, body mass index (BMI) 30.3 ± 5.8] were included. When the femur and tibia were taken together, exact size match was observed in 34% (95% CI 29.9–38.3%) of cases, accurate size match in 57.5% (95% CI 53–61.8%) and inaccurate size match in 8.5% (95% CI 6.3–11.2%). Inaccurate size match prolonged operative time (p = 0.028). Regarding the factors potentially influencing templating accuracy, only gender had a significant influence, with templating being more accurate in men (p = 0.004). BMI had no influence on accuracy (p = 0.87). No effect on accuracy was observed for implant type and surgeon experience. CONCLUSIONS: The accuracy of 2D size templating in TKA is low, even in a specialized ENDOCERT arthroplasty center. The study findings challenge the usefulness of preoperative 2D size templating and highlight the importance of more reliable templating methods. LEVEL OF EVIDENCE: Level III (retrospective observational study). |
format | Online Article Text |
id | pubmed-10374828 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-103748282023-07-29 Imprecise prediction of implant sizes with preoperative 2D digital templating in total knee arthroplasty Riechelmann, Felix Lettner, H. Mayr, R. Tandogan, R. Dammerer, D. Liebensteiner, M. Arch Orthop Trauma Surg Orthopaedic Surgery PURPOSE: To analyze the match between preoperatively determined implant size (2D templating) and intraoperatively used implant size in total knee arthroplasty (TKA). Also examined were the factors that might influence templating accuracy (gender, surgeon experience, obesity, etc.). MATERIALS AND METHODS: The study was retrospective and conducted in a specialized ENDOCERT arthroplasty center. Digital templating was done with the MediCAD software. If the planned and implanted TKA components (both femur and tibia) were the same size, the match was classified “exact.” A deviation of ± one size (at the femur or tibia or both) was classified “accurate.” A deviation of ± two or more sizes (at the femur or tibia or both) was classified “inaccurate.” Obesity, gender, implant type and surgeon experience were investigated for potential influence on templating accuracy. Chi-square tests and Cohen’s weighted kappa test were used for statistical analysis. RESULTS: A total of 482 cases [33.6% male, 66.4% female, age 69 ± 11, body mass index (BMI) 30.3 ± 5.8] were included. When the femur and tibia were taken together, exact size match was observed in 34% (95% CI 29.9–38.3%) of cases, accurate size match in 57.5% (95% CI 53–61.8%) and inaccurate size match in 8.5% (95% CI 6.3–11.2%). Inaccurate size match prolonged operative time (p = 0.028). Regarding the factors potentially influencing templating accuracy, only gender had a significant influence, with templating being more accurate in men (p = 0.004). BMI had no influence on accuracy (p = 0.87). No effect on accuracy was observed for implant type and surgeon experience. CONCLUSIONS: The accuracy of 2D size templating in TKA is low, even in a specialized ENDOCERT arthroplasty center. The study findings challenge the usefulness of preoperative 2D size templating and highlight the importance of more reliable templating methods. LEVEL OF EVIDENCE: Level III (retrospective observational study). Springer Berlin Heidelberg 2023-01-17 2023 /pmc/articles/PMC10374828/ /pubmed/36648539 http://dx.doi.org/10.1007/s00402-023-04772-7 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Orthopaedic Surgery Riechelmann, Felix Lettner, H. Mayr, R. Tandogan, R. Dammerer, D. Liebensteiner, M. Imprecise prediction of implant sizes with preoperative 2D digital templating in total knee arthroplasty |
title | Imprecise prediction of implant sizes with preoperative 2D digital templating in total knee arthroplasty |
title_full | Imprecise prediction of implant sizes with preoperative 2D digital templating in total knee arthroplasty |
title_fullStr | Imprecise prediction of implant sizes with preoperative 2D digital templating in total knee arthroplasty |
title_full_unstemmed | Imprecise prediction of implant sizes with preoperative 2D digital templating in total knee arthroplasty |
title_short | Imprecise prediction of implant sizes with preoperative 2D digital templating in total knee arthroplasty |
title_sort | imprecise prediction of implant sizes with preoperative 2d digital templating in total knee arthroplasty |
topic | Orthopaedic Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10374828/ https://www.ncbi.nlm.nih.gov/pubmed/36648539 http://dx.doi.org/10.1007/s00402-023-04772-7 |
work_keys_str_mv | AT riechelmannfelix imprecisepredictionofimplantsizeswithpreoperative2ddigitaltemplatingintotalkneearthroplasty AT lettnerh imprecisepredictionofimplantsizeswithpreoperative2ddigitaltemplatingintotalkneearthroplasty AT mayrr imprecisepredictionofimplantsizeswithpreoperative2ddigitaltemplatingintotalkneearthroplasty AT tandoganr imprecisepredictionofimplantsizeswithpreoperative2ddigitaltemplatingintotalkneearthroplasty AT dammererd imprecisepredictionofimplantsizeswithpreoperative2ddigitaltemplatingintotalkneearthroplasty AT liebensteinerm imprecisepredictionofimplantsizeswithpreoperative2ddigitaltemplatingintotalkneearthroplasty |