Cargando…

An Extremely Rare Case of Cementless Third Generation Corail Stem Neck Fracture With Fractographic Analysis

The cementless Corail stem is one of the most frequently implanted stems and has undergone several design changes. Currently in use is the third generation, named Corail AMT. Until now, only one third-generation Corail stem neck fracture has been described in 2020. In our paper, we present an almost...

Descripción completa

Detalles Bibliográficos
Autores principales: Baljozovic, Andreja, Glisic, Dragomir, Radovic, Nenad, Radovanović, Zeljko, Bascarevic, Zoran
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10374864/
https://www.ncbi.nlm.nih.gov/pubmed/37521731
http://dx.doi.org/10.1016/j.artd.2023.101176
_version_ 1785078870642262016
author Baljozovic, Andreja
Glisic, Dragomir
Radovic, Nenad
Radovanović, Zeljko
Bascarevic, Zoran
author_facet Baljozovic, Andreja
Glisic, Dragomir
Radovic, Nenad
Radovanović, Zeljko
Bascarevic, Zoran
author_sort Baljozovic, Andreja
collection PubMed
description The cementless Corail stem is one of the most frequently implanted stems and has undergone several design changes. Currently in use is the third generation, named Corail AMT. Until now, only one third-generation Corail stem neck fracture has been described in 2020. In our paper, we present an almost identical complication with an additional analysis of the fracture using a scanning electron microscope. The revision surgery consisted of changing the broken implant with a Corail revision stem, along with replacing the polyethylene liner and the femoral head with new one, after which the patient achieved a full recovery. According to the available literature, this is the second case of this extremely rare complication.
format Online
Article
Text
id pubmed-10374864
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-103748642023-07-29 An Extremely Rare Case of Cementless Third Generation Corail Stem Neck Fracture With Fractographic Analysis Baljozovic, Andreja Glisic, Dragomir Radovic, Nenad Radovanović, Zeljko Bascarevic, Zoran Arthroplast Today Case Report The cementless Corail stem is one of the most frequently implanted stems and has undergone several design changes. Currently in use is the third generation, named Corail AMT. Until now, only one third-generation Corail stem neck fracture has been described in 2020. In our paper, we present an almost identical complication with an additional analysis of the fracture using a scanning electron microscope. The revision surgery consisted of changing the broken implant with a Corail revision stem, along with replacing the polyethylene liner and the femoral head with new one, after which the patient achieved a full recovery. According to the available literature, this is the second case of this extremely rare complication. Elsevier 2023-07-22 /pmc/articles/PMC10374864/ /pubmed/37521731 http://dx.doi.org/10.1016/j.artd.2023.101176 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Baljozovic, Andreja
Glisic, Dragomir
Radovic, Nenad
Radovanović, Zeljko
Bascarevic, Zoran
An Extremely Rare Case of Cementless Third Generation Corail Stem Neck Fracture With Fractographic Analysis
title An Extremely Rare Case of Cementless Third Generation Corail Stem Neck Fracture With Fractographic Analysis
title_full An Extremely Rare Case of Cementless Third Generation Corail Stem Neck Fracture With Fractographic Analysis
title_fullStr An Extremely Rare Case of Cementless Third Generation Corail Stem Neck Fracture With Fractographic Analysis
title_full_unstemmed An Extremely Rare Case of Cementless Third Generation Corail Stem Neck Fracture With Fractographic Analysis
title_short An Extremely Rare Case of Cementless Third Generation Corail Stem Neck Fracture With Fractographic Analysis
title_sort extremely rare case of cementless third generation corail stem neck fracture with fractographic analysis
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10374864/
https://www.ncbi.nlm.nih.gov/pubmed/37521731
http://dx.doi.org/10.1016/j.artd.2023.101176
work_keys_str_mv AT baljozovicandreja anextremelyrarecaseofcementlessthirdgenerationcorailstemneckfracturewithfractographicanalysis
AT glisicdragomir anextremelyrarecaseofcementlessthirdgenerationcorailstemneckfracturewithfractographicanalysis
AT radovicnenad anextremelyrarecaseofcementlessthirdgenerationcorailstemneckfracturewithfractographicanalysis
AT radovanoviczeljko anextremelyrarecaseofcementlessthirdgenerationcorailstemneckfracturewithfractographicanalysis
AT bascareviczoran anextremelyrarecaseofcementlessthirdgenerationcorailstemneckfracturewithfractographicanalysis
AT baljozovicandreja extremelyrarecaseofcementlessthirdgenerationcorailstemneckfracturewithfractographicanalysis
AT glisicdragomir extremelyrarecaseofcementlessthirdgenerationcorailstemneckfracturewithfractographicanalysis
AT radovicnenad extremelyrarecaseofcementlessthirdgenerationcorailstemneckfracturewithfractographicanalysis
AT radovanoviczeljko extremelyrarecaseofcementlessthirdgenerationcorailstemneckfracturewithfractographicanalysis
AT bascareviczoran extremelyrarecaseofcementlessthirdgenerationcorailstemneckfracturewithfractographicanalysis