Magnetic Resonance Safety Evaluation of a Novel Alumina Matrix Composite Ceramic Knee and Image Artifact Comparison to a Metal Knee Implant of Analogous Design
BACKGROUND: Image artifacts caused by metal knee implants in 1.5T and 3T magnetic resonance imaging (MRI) systems complicate imaging-based diagnosis of the peri-implant region after total knee arthroplasty. Alternatively, metal-free knee prostheses could effectively minimize MRI safety hazards and o...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10374871/ https://www.ncbi.nlm.nih.gov/pubmed/37521740 http://dx.doi.org/10.1016/j.artd.2023.101170 |
_version_ | 1785078872297963520 |
---|---|
author | Mödinger, Yvonne Anttila, Eric D. Baker, Grant M. Gross, David C. Porporati, Alessandro A. |
author_facet | Mödinger, Yvonne Anttila, Eric D. Baker, Grant M. Gross, David C. Porporati, Alessandro A. |
author_sort | Mödinger, Yvonne |
collection | PubMed |
description | BACKGROUND: Image artifacts caused by metal knee implants in 1.5T and 3T magnetic resonance imaging (MRI) systems complicate imaging-based diagnosis of the peri-implant region after total knee arthroplasty. Alternatively, metal-free knee prostheses could effectively minimize MRI safety hazards and offer the potential for higher quality diagnostic images. METHODS: A novel knee arthroplasty device composed of BIOLOX delta, an alumina matrix composite (AMC) ceramic, was tested in a magnetic resonance (MR) environment. American Society for Testing and Materials test methods were used for evaluating magnetically induced displacement force, magnetically induced torque, radiofrequency-induced heating, and MR image artifact. RESULTS: Magnetically induced displacement force and magnetically induced torque results of the AMC ceramic knee indicated that these effects do not pose a known risk in a clinical MR environment, as assessed in a 3T magnetic field. Moreover, minimal radiofrequency-induced heating of the device was observed. In addition, the AMC ceramic knee demonstrated minimal MR image artifacts (7 mm) in comparison to a cobalt-chromium knee (88 mm). The extremely low magnetic susceptibility of AMC (2 ppm) underlines that it is a nonmetallic and nonmagnetic material well suited for the manufacturing of MR Safe orthopaedic implants. CONCLUSIONS: The AMC ceramic knee is a novel metal-free total knee arthroplasty device that can be regarded as MR Safe, as suggested by the absence of hazards from the exposure of this implant to a MR environment. The AMC ceramic knee presents the advantage of being scanned with superior imaging results in 3T MRI systems compared to alternative metal implants on the market. |
format | Online Article Text |
id | pubmed-10374871 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-103748712023-07-29 Magnetic Resonance Safety Evaluation of a Novel Alumina Matrix Composite Ceramic Knee and Image Artifact Comparison to a Metal Knee Implant of Analogous Design Mödinger, Yvonne Anttila, Eric D. Baker, Grant M. Gross, David C. Porporati, Alessandro A. Arthroplast Today Original Research BACKGROUND: Image artifacts caused by metal knee implants in 1.5T and 3T magnetic resonance imaging (MRI) systems complicate imaging-based diagnosis of the peri-implant region after total knee arthroplasty. Alternatively, metal-free knee prostheses could effectively minimize MRI safety hazards and offer the potential for higher quality diagnostic images. METHODS: A novel knee arthroplasty device composed of BIOLOX delta, an alumina matrix composite (AMC) ceramic, was tested in a magnetic resonance (MR) environment. American Society for Testing and Materials test methods were used for evaluating magnetically induced displacement force, magnetically induced torque, radiofrequency-induced heating, and MR image artifact. RESULTS: Magnetically induced displacement force and magnetically induced torque results of the AMC ceramic knee indicated that these effects do not pose a known risk in a clinical MR environment, as assessed in a 3T magnetic field. Moreover, minimal radiofrequency-induced heating of the device was observed. In addition, the AMC ceramic knee demonstrated minimal MR image artifacts (7 mm) in comparison to a cobalt-chromium knee (88 mm). The extremely low magnetic susceptibility of AMC (2 ppm) underlines that it is a nonmetallic and nonmagnetic material well suited for the manufacturing of MR Safe orthopaedic implants. CONCLUSIONS: The AMC ceramic knee is a novel metal-free total knee arthroplasty device that can be regarded as MR Safe, as suggested by the absence of hazards from the exposure of this implant to a MR environment. The AMC ceramic knee presents the advantage of being scanned with superior imaging results in 3T MRI systems compared to alternative metal implants on the market. Elsevier 2023-07-23 /pmc/articles/PMC10374871/ /pubmed/37521740 http://dx.doi.org/10.1016/j.artd.2023.101170 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Research Mödinger, Yvonne Anttila, Eric D. Baker, Grant M. Gross, David C. Porporati, Alessandro A. Magnetic Resonance Safety Evaluation of a Novel Alumina Matrix Composite Ceramic Knee and Image Artifact Comparison to a Metal Knee Implant of Analogous Design |
title | Magnetic Resonance Safety Evaluation of a Novel Alumina Matrix Composite Ceramic Knee and Image Artifact Comparison to a Metal Knee Implant of Analogous Design |
title_full | Magnetic Resonance Safety Evaluation of a Novel Alumina Matrix Composite Ceramic Knee and Image Artifact Comparison to a Metal Knee Implant of Analogous Design |
title_fullStr | Magnetic Resonance Safety Evaluation of a Novel Alumina Matrix Composite Ceramic Knee and Image Artifact Comparison to a Metal Knee Implant of Analogous Design |
title_full_unstemmed | Magnetic Resonance Safety Evaluation of a Novel Alumina Matrix Composite Ceramic Knee and Image Artifact Comparison to a Metal Knee Implant of Analogous Design |
title_short | Magnetic Resonance Safety Evaluation of a Novel Alumina Matrix Composite Ceramic Knee and Image Artifact Comparison to a Metal Knee Implant of Analogous Design |
title_sort | magnetic resonance safety evaluation of a novel alumina matrix composite ceramic knee and image artifact comparison to a metal knee implant of analogous design |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10374871/ https://www.ncbi.nlm.nih.gov/pubmed/37521740 http://dx.doi.org/10.1016/j.artd.2023.101170 |
work_keys_str_mv | AT modingeryvonne magneticresonancesafetyevaluationofanovelaluminamatrixcompositeceramickneeandimageartifactcomparisontoametalkneeimplantofanalogousdesign AT anttilaericd magneticresonancesafetyevaluationofanovelaluminamatrixcompositeceramickneeandimageartifactcomparisontoametalkneeimplantofanalogousdesign AT bakergrantm magneticresonancesafetyevaluationofanovelaluminamatrixcompositeceramickneeandimageartifactcomparisontoametalkneeimplantofanalogousdesign AT grossdavidc magneticresonancesafetyevaluationofanovelaluminamatrixcompositeceramickneeandimageartifactcomparisontoametalkneeimplantofanalogousdesign AT porporatialessandroa magneticresonancesafetyevaluationofanovelaluminamatrixcompositeceramickneeandimageartifactcomparisontoametalkneeimplantofanalogousdesign |