Cargando…

How the Porous Transport Layer Interface Affects Catalyst Utilization and Performance in Polymer Electrolyte Water Electrolysis

[Image: see text] Cost reduction and fast scale-up of electrolyzer technologies are essential for decarbonizing several crucial branches of industry. For polymer electrolyte water electrolysis, this requires a dramatic reduction of the expensive and scarce iridium-based catalyst, making its efficien...

Descripción completa

Detalles Bibliográficos
Autores principales: Weber, Carl Cesar, Wrubel, Jacob A., Gubler, Lorenz, Bender, Guido, De Angelis, Salvatore, Büchi, Felix N.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2023
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10375438/
https://www.ncbi.nlm.nih.gov/pubmed/37459180
http://dx.doi.org/10.1021/acsami.3c04151
_version_ 1785079038212046848
author Weber, Carl Cesar
Wrubel, Jacob A.
Gubler, Lorenz
Bender, Guido
De Angelis, Salvatore
Büchi, Felix N.
author_facet Weber, Carl Cesar
Wrubel, Jacob A.
Gubler, Lorenz
Bender, Guido
De Angelis, Salvatore
Büchi, Felix N.
author_sort Weber, Carl Cesar
collection PubMed
description [Image: see text] Cost reduction and fast scale-up of electrolyzer technologies are essential for decarbonizing several crucial branches of industry. For polymer electrolyte water electrolysis, this requires a dramatic reduction of the expensive and scarce iridium-based catalyst, making its efficient utilization a key factor. The interfacial properties between the porous transport layer (PTL) and the catalyst layer (CL) are crucial for optimal catalyst utilization. Therefore, it is essential to understand the relationship between this interface and electrochemical performance. In this study, we fabricated a matrix of two-dimensional interface layers with a well-known model structure, integrating them as an additional layer between the PTL and the CL. By characterizing the performance and conducting an in-depth analysis of the overpotentials, we were able to estimate the catalyst utilization at different current densities, correlating them to the geometric properties of the model PTLs. We found that large areas of the CL become inactive at increasing current density either due to dry-out, oxygen saturation (under the PTL), or the high resistance of the CL away from the pore edges. We experimentally estimated the water penetration in the CL under the PTL to be ≈20 μm. Experimental results were corroborated using a 3D-multiphysics model to calculate the current distribution in the CL and estimate the impact of membrane dry-out. Finally, we observed a strong pressure dependency on performance and high-frequency resistance, which indicates that with the employed model PTLs, a significant gas phase accumulates in the CL under the lands, hindering the distribution of liquid water. The findings of this work can be extrapolated to improve and engineer PTLs with advanced interface properties, helping to reach the required target goals in cost and iridium loadings.
format Online
Article
Text
id pubmed-10375438
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-103754382023-07-29 How the Porous Transport Layer Interface Affects Catalyst Utilization and Performance in Polymer Electrolyte Water Electrolysis Weber, Carl Cesar Wrubel, Jacob A. Gubler, Lorenz Bender, Guido De Angelis, Salvatore Büchi, Felix N. ACS Appl Mater Interfaces [Image: see text] Cost reduction and fast scale-up of electrolyzer technologies are essential for decarbonizing several crucial branches of industry. For polymer electrolyte water electrolysis, this requires a dramatic reduction of the expensive and scarce iridium-based catalyst, making its efficient utilization a key factor. The interfacial properties between the porous transport layer (PTL) and the catalyst layer (CL) are crucial for optimal catalyst utilization. Therefore, it is essential to understand the relationship between this interface and electrochemical performance. In this study, we fabricated a matrix of two-dimensional interface layers with a well-known model structure, integrating them as an additional layer between the PTL and the CL. By characterizing the performance and conducting an in-depth analysis of the overpotentials, we were able to estimate the catalyst utilization at different current densities, correlating them to the geometric properties of the model PTLs. We found that large areas of the CL become inactive at increasing current density either due to dry-out, oxygen saturation (under the PTL), or the high resistance of the CL away from the pore edges. We experimentally estimated the water penetration in the CL under the PTL to be ≈20 μm. Experimental results were corroborated using a 3D-multiphysics model to calculate the current distribution in the CL and estimate the impact of membrane dry-out. Finally, we observed a strong pressure dependency on performance and high-frequency resistance, which indicates that with the employed model PTLs, a significant gas phase accumulates in the CL under the lands, hindering the distribution of liquid water. The findings of this work can be extrapolated to improve and engineer PTLs with advanced interface properties, helping to reach the required target goals in cost and iridium loadings. American Chemical Society 2023-07-17 /pmc/articles/PMC10375438/ /pubmed/37459180 http://dx.doi.org/10.1021/acsami.3c04151 Text en © 2023 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by/4.0/Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Weber, Carl Cesar
Wrubel, Jacob A.
Gubler, Lorenz
Bender, Guido
De Angelis, Salvatore
Büchi, Felix N.
How the Porous Transport Layer Interface Affects Catalyst Utilization and Performance in Polymer Electrolyte Water Electrolysis
title How the Porous Transport Layer Interface Affects Catalyst Utilization and Performance in Polymer Electrolyte Water Electrolysis
title_full How the Porous Transport Layer Interface Affects Catalyst Utilization and Performance in Polymer Electrolyte Water Electrolysis
title_fullStr How the Porous Transport Layer Interface Affects Catalyst Utilization and Performance in Polymer Electrolyte Water Electrolysis
title_full_unstemmed How the Porous Transport Layer Interface Affects Catalyst Utilization and Performance in Polymer Electrolyte Water Electrolysis
title_short How the Porous Transport Layer Interface Affects Catalyst Utilization and Performance in Polymer Electrolyte Water Electrolysis
title_sort how the porous transport layer interface affects catalyst utilization and performance in polymer electrolyte water electrolysis
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10375438/
https://www.ncbi.nlm.nih.gov/pubmed/37459180
http://dx.doi.org/10.1021/acsami.3c04151
work_keys_str_mv AT webercarlcesar howtheporoustransportlayerinterfaceaffectscatalystutilizationandperformanceinpolymerelectrolytewaterelectrolysis
AT wrubeljacoba howtheporoustransportlayerinterfaceaffectscatalystutilizationandperformanceinpolymerelectrolytewaterelectrolysis
AT gublerlorenz howtheporoustransportlayerinterfaceaffectscatalystutilizationandperformanceinpolymerelectrolytewaterelectrolysis
AT benderguido howtheporoustransportlayerinterfaceaffectscatalystutilizationandperformanceinpolymerelectrolytewaterelectrolysis
AT deangelissalvatore howtheporoustransportlayerinterfaceaffectscatalystutilizationandperformanceinpolymerelectrolytewaterelectrolysis
AT buchifelixn howtheporoustransportlayerinterfaceaffectscatalystutilizationandperformanceinpolymerelectrolytewaterelectrolysis