Cargando…
How the Porous Transport Layer Interface Affects Catalyst Utilization and Performance in Polymer Electrolyte Water Electrolysis
[Image: see text] Cost reduction and fast scale-up of electrolyzer technologies are essential for decarbonizing several crucial branches of industry. For polymer electrolyte water electrolysis, this requires a dramatic reduction of the expensive and scarce iridium-based catalyst, making its efficien...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Chemical Society
2023
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10375438/ https://www.ncbi.nlm.nih.gov/pubmed/37459180 http://dx.doi.org/10.1021/acsami.3c04151 |
_version_ | 1785079038212046848 |
---|---|
author | Weber, Carl Cesar Wrubel, Jacob A. Gubler, Lorenz Bender, Guido De Angelis, Salvatore Büchi, Felix N. |
author_facet | Weber, Carl Cesar Wrubel, Jacob A. Gubler, Lorenz Bender, Guido De Angelis, Salvatore Büchi, Felix N. |
author_sort | Weber, Carl Cesar |
collection | PubMed |
description | [Image: see text] Cost reduction and fast scale-up of electrolyzer technologies are essential for decarbonizing several crucial branches of industry. For polymer electrolyte water electrolysis, this requires a dramatic reduction of the expensive and scarce iridium-based catalyst, making its efficient utilization a key factor. The interfacial properties between the porous transport layer (PTL) and the catalyst layer (CL) are crucial for optimal catalyst utilization. Therefore, it is essential to understand the relationship between this interface and electrochemical performance. In this study, we fabricated a matrix of two-dimensional interface layers with a well-known model structure, integrating them as an additional layer between the PTL and the CL. By characterizing the performance and conducting an in-depth analysis of the overpotentials, we were able to estimate the catalyst utilization at different current densities, correlating them to the geometric properties of the model PTLs. We found that large areas of the CL become inactive at increasing current density either due to dry-out, oxygen saturation (under the PTL), or the high resistance of the CL away from the pore edges. We experimentally estimated the water penetration in the CL under the PTL to be ≈20 μm. Experimental results were corroborated using a 3D-multiphysics model to calculate the current distribution in the CL and estimate the impact of membrane dry-out. Finally, we observed a strong pressure dependency on performance and high-frequency resistance, which indicates that with the employed model PTLs, a significant gas phase accumulates in the CL under the lands, hindering the distribution of liquid water. The findings of this work can be extrapolated to improve and engineer PTLs with advanced interface properties, helping to reach the required target goals in cost and iridium loadings. |
format | Online Article Text |
id | pubmed-10375438 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | American Chemical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-103754382023-07-29 How the Porous Transport Layer Interface Affects Catalyst Utilization and Performance in Polymer Electrolyte Water Electrolysis Weber, Carl Cesar Wrubel, Jacob A. Gubler, Lorenz Bender, Guido De Angelis, Salvatore Büchi, Felix N. ACS Appl Mater Interfaces [Image: see text] Cost reduction and fast scale-up of electrolyzer technologies are essential for decarbonizing several crucial branches of industry. For polymer electrolyte water electrolysis, this requires a dramatic reduction of the expensive and scarce iridium-based catalyst, making its efficient utilization a key factor. The interfacial properties between the porous transport layer (PTL) and the catalyst layer (CL) are crucial for optimal catalyst utilization. Therefore, it is essential to understand the relationship between this interface and electrochemical performance. In this study, we fabricated a matrix of two-dimensional interface layers with a well-known model structure, integrating them as an additional layer between the PTL and the CL. By characterizing the performance and conducting an in-depth analysis of the overpotentials, we were able to estimate the catalyst utilization at different current densities, correlating them to the geometric properties of the model PTLs. We found that large areas of the CL become inactive at increasing current density either due to dry-out, oxygen saturation (under the PTL), or the high resistance of the CL away from the pore edges. We experimentally estimated the water penetration in the CL under the PTL to be ≈20 μm. Experimental results were corroborated using a 3D-multiphysics model to calculate the current distribution in the CL and estimate the impact of membrane dry-out. Finally, we observed a strong pressure dependency on performance and high-frequency resistance, which indicates that with the employed model PTLs, a significant gas phase accumulates in the CL under the lands, hindering the distribution of liquid water. The findings of this work can be extrapolated to improve and engineer PTLs with advanced interface properties, helping to reach the required target goals in cost and iridium loadings. American Chemical Society 2023-07-17 /pmc/articles/PMC10375438/ /pubmed/37459180 http://dx.doi.org/10.1021/acsami.3c04151 Text en © 2023 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by/4.0/Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Weber, Carl Cesar Wrubel, Jacob A. Gubler, Lorenz Bender, Guido De Angelis, Salvatore Büchi, Felix N. How the Porous Transport Layer Interface Affects Catalyst Utilization and Performance in Polymer Electrolyte Water Electrolysis |
title | How
the Porous Transport Layer Interface Affects Catalyst
Utilization and Performance in Polymer Electrolyte Water Electrolysis |
title_full | How
the Porous Transport Layer Interface Affects Catalyst
Utilization and Performance in Polymer Electrolyte Water Electrolysis |
title_fullStr | How
the Porous Transport Layer Interface Affects Catalyst
Utilization and Performance in Polymer Electrolyte Water Electrolysis |
title_full_unstemmed | How
the Porous Transport Layer Interface Affects Catalyst
Utilization and Performance in Polymer Electrolyte Water Electrolysis |
title_short | How
the Porous Transport Layer Interface Affects Catalyst
Utilization and Performance in Polymer Electrolyte Water Electrolysis |
title_sort | how
the porous transport layer interface affects catalyst
utilization and performance in polymer electrolyte water electrolysis |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10375438/ https://www.ncbi.nlm.nih.gov/pubmed/37459180 http://dx.doi.org/10.1021/acsami.3c04151 |
work_keys_str_mv | AT webercarlcesar howtheporoustransportlayerinterfaceaffectscatalystutilizationandperformanceinpolymerelectrolytewaterelectrolysis AT wrubeljacoba howtheporoustransportlayerinterfaceaffectscatalystutilizationandperformanceinpolymerelectrolytewaterelectrolysis AT gublerlorenz howtheporoustransportlayerinterfaceaffectscatalystutilizationandperformanceinpolymerelectrolytewaterelectrolysis AT benderguido howtheporoustransportlayerinterfaceaffectscatalystutilizationandperformanceinpolymerelectrolytewaterelectrolysis AT deangelissalvatore howtheporoustransportlayerinterfaceaffectscatalystutilizationandperformanceinpolymerelectrolytewaterelectrolysis AT buchifelixn howtheporoustransportlayerinterfaceaffectscatalystutilizationandperformanceinpolymerelectrolytewaterelectrolysis |