Cargando…

Antibiotic, Heavy Metal, and Biocide Concentrations in a Wastewater Treatment Plant and Its Receiving Water Body Exceed PNEC Limits: Potential for Antimicrobial Resistance Selective Pressure

Although the rise in antimicrobial resistance has been attributed mainly to the extensive and indiscriminate use of antimicrobials such as antibiotics and biocides in humans, animals and on plants, studies investigating the impact of this use on water environments in Africa are minimal. This study q...

Descripción completa

Detalles Bibliográficos
Autores principales: Chukwu, Kelechi B., Abafe, Ovokeroye A., Amoako, Daniel G., Essack, Sabiha Y., Abia, Akebe L. K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10376008/
https://www.ncbi.nlm.nih.gov/pubmed/37508262
http://dx.doi.org/10.3390/antibiotics12071166
_version_ 1785079165184114688
author Chukwu, Kelechi B.
Abafe, Ovokeroye A.
Amoako, Daniel G.
Essack, Sabiha Y.
Abia, Akebe L. K.
author_facet Chukwu, Kelechi B.
Abafe, Ovokeroye A.
Amoako, Daniel G.
Essack, Sabiha Y.
Abia, Akebe L. K.
author_sort Chukwu, Kelechi B.
collection PubMed
description Although the rise in antimicrobial resistance has been attributed mainly to the extensive and indiscriminate use of antimicrobials such as antibiotics and biocides in humans, animals and on plants, studies investigating the impact of this use on water environments in Africa are minimal. This study quantified selected antibiotics, heavy metals, and biocides in an urban wastewater treatment plant (WWTP) and its receiving water body in Kwazulu-Natal, South Africa, in the context of the predicted no-effect concentrations (PNEC) for the selection of antimicrobial resistance (AMR). Water samples were collected from the WWTP effluent discharge point and upstream and downstream from this point. Heavy metals were identified and quantified using the United States Environmental Protection Agency (US EPA) method 200.7. Biocides and antibiotic residues were determined using validated ultra-high-performance liquid chromatography with tandem mass spectrometry-based methods. The overall highest mean antibiotic, metal and biocide concentrations were observed for sulfamethoxazole (286.180 µg/L), neodymium (Nd; 27.734 mg/L), and benzalkonium chloride (BAC 12) (7.805 µg/L), respectively. In decreasing order per sampling site, the pollutant concentrations were effluent > downstream > upstream. This implies that the WWTP significantly contributed to the observed pollution in the receiving water. Furthermore, most of the pollutants measured recorded values exceeding the recommended predicted no-effect concentration (PNEC) values, suggesting that the microbes in such water environments were at risk of developing resistance due to the selection pressure exerted by these antimicrobials. Further studies are required to establish such a relationship.
format Online
Article
Text
id pubmed-10376008
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103760082023-07-29 Antibiotic, Heavy Metal, and Biocide Concentrations in a Wastewater Treatment Plant and Its Receiving Water Body Exceed PNEC Limits: Potential for Antimicrobial Resistance Selective Pressure Chukwu, Kelechi B. Abafe, Ovokeroye A. Amoako, Daniel G. Essack, Sabiha Y. Abia, Akebe L. K. Antibiotics (Basel) Article Although the rise in antimicrobial resistance has been attributed mainly to the extensive and indiscriminate use of antimicrobials such as antibiotics and biocides in humans, animals and on plants, studies investigating the impact of this use on water environments in Africa are minimal. This study quantified selected antibiotics, heavy metals, and biocides in an urban wastewater treatment plant (WWTP) and its receiving water body in Kwazulu-Natal, South Africa, in the context of the predicted no-effect concentrations (PNEC) for the selection of antimicrobial resistance (AMR). Water samples were collected from the WWTP effluent discharge point and upstream and downstream from this point. Heavy metals were identified and quantified using the United States Environmental Protection Agency (US EPA) method 200.7. Biocides and antibiotic residues were determined using validated ultra-high-performance liquid chromatography with tandem mass spectrometry-based methods. The overall highest mean antibiotic, metal and biocide concentrations were observed for sulfamethoxazole (286.180 µg/L), neodymium (Nd; 27.734 mg/L), and benzalkonium chloride (BAC 12) (7.805 µg/L), respectively. In decreasing order per sampling site, the pollutant concentrations were effluent > downstream > upstream. This implies that the WWTP significantly contributed to the observed pollution in the receiving water. Furthermore, most of the pollutants measured recorded values exceeding the recommended predicted no-effect concentration (PNEC) values, suggesting that the microbes in such water environments were at risk of developing resistance due to the selection pressure exerted by these antimicrobials. Further studies are required to establish such a relationship. MDPI 2023-07-09 /pmc/articles/PMC10376008/ /pubmed/37508262 http://dx.doi.org/10.3390/antibiotics12071166 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Chukwu, Kelechi B.
Abafe, Ovokeroye A.
Amoako, Daniel G.
Essack, Sabiha Y.
Abia, Akebe L. K.
Antibiotic, Heavy Metal, and Biocide Concentrations in a Wastewater Treatment Plant and Its Receiving Water Body Exceed PNEC Limits: Potential for Antimicrobial Resistance Selective Pressure
title Antibiotic, Heavy Metal, and Biocide Concentrations in a Wastewater Treatment Plant and Its Receiving Water Body Exceed PNEC Limits: Potential for Antimicrobial Resistance Selective Pressure
title_full Antibiotic, Heavy Metal, and Biocide Concentrations in a Wastewater Treatment Plant and Its Receiving Water Body Exceed PNEC Limits: Potential for Antimicrobial Resistance Selective Pressure
title_fullStr Antibiotic, Heavy Metal, and Biocide Concentrations in a Wastewater Treatment Plant and Its Receiving Water Body Exceed PNEC Limits: Potential for Antimicrobial Resistance Selective Pressure
title_full_unstemmed Antibiotic, Heavy Metal, and Biocide Concentrations in a Wastewater Treatment Plant and Its Receiving Water Body Exceed PNEC Limits: Potential for Antimicrobial Resistance Selective Pressure
title_short Antibiotic, Heavy Metal, and Biocide Concentrations in a Wastewater Treatment Plant and Its Receiving Water Body Exceed PNEC Limits: Potential for Antimicrobial Resistance Selective Pressure
title_sort antibiotic, heavy metal, and biocide concentrations in a wastewater treatment plant and its receiving water body exceed pnec limits: potential for antimicrobial resistance selective pressure
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10376008/
https://www.ncbi.nlm.nih.gov/pubmed/37508262
http://dx.doi.org/10.3390/antibiotics12071166
work_keys_str_mv AT chukwukelechib antibioticheavymetalandbiocideconcentrationsinawastewatertreatmentplantanditsreceivingwaterbodyexceedpneclimitspotentialforantimicrobialresistanceselectivepressure
AT abafeovokeroyea antibioticheavymetalandbiocideconcentrationsinawastewatertreatmentplantanditsreceivingwaterbodyexceedpneclimitspotentialforantimicrobialresistanceselectivepressure
AT amoakodanielg antibioticheavymetalandbiocideconcentrationsinawastewatertreatmentplantanditsreceivingwaterbodyexceedpneclimitspotentialforantimicrobialresistanceselectivepressure
AT essacksabihay antibioticheavymetalandbiocideconcentrationsinawastewatertreatmentplantanditsreceivingwaterbodyexceedpneclimitspotentialforantimicrobialresistanceselectivepressure
AT abiaakebelk antibioticheavymetalandbiocideconcentrationsinawastewatertreatmentplantanditsreceivingwaterbodyexceedpneclimitspotentialforantimicrobialresistanceselectivepressure