Cargando…

Comparison of Disk Diffusion, E-Test, and Broth Microdilution Methods for Testing In Vitro Activity of Cefiderocol in Acinetobacter baumannii

The reference method for cefiderocol antimicrobial susceptibility testing is broth microdilution (BMD) with iron-depleted-Mueller-Hinton (ID-MH) medium, whereas breakpoints recommended for disk diffusion (DD) are based on MH-agar plates. We aimed to compare the performance of the commercial BMD test...

Descripción completa

Detalles Bibliográficos
Autores principales: Kolesnik-Goldmann, Natalia, Seth-Smith, Helena M. B., Haldimann, Klara, Imkamp, Frank, Roloff, Tim, Zbinden, Reinhard, Hobbie, Sven N., Egli, Adrian, Mancini, Stefano
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10376138/
https://www.ncbi.nlm.nih.gov/pubmed/37508308
http://dx.doi.org/10.3390/antibiotics12071212
_version_ 1785079196540731392
author Kolesnik-Goldmann, Natalia
Seth-Smith, Helena M. B.
Haldimann, Klara
Imkamp, Frank
Roloff, Tim
Zbinden, Reinhard
Hobbie, Sven N.
Egli, Adrian
Mancini, Stefano
author_facet Kolesnik-Goldmann, Natalia
Seth-Smith, Helena M. B.
Haldimann, Klara
Imkamp, Frank
Roloff, Tim
Zbinden, Reinhard
Hobbie, Sven N.
Egli, Adrian
Mancini, Stefano
author_sort Kolesnik-Goldmann, Natalia
collection PubMed
description The reference method for cefiderocol antimicrobial susceptibility testing is broth microdilution (BMD) with iron-depleted-Mueller-Hinton (ID-MH) medium, whereas breakpoints recommended for disk diffusion (DD) are based on MH-agar plates. We aimed to compare the performance of the commercial BMD tests ComASP (Liofilchem) and UMIC (Bruker), and DD and E-test using MH- and ID-MH-agar plates with the reference BMD method using 100 carbapenem-resistant-A. baumannii isolates. Standard BMD was performed according to the EUCAST guidelines; DD and E-test were carried out using two commercial MH-agar plates (BioMérieux and Liofilchem) and an in-house ID-MH-agar plate, while ComASP and UMIC were performed according to the manufacturer’s guidelines. DD performed with the ID-MH-agar plates led to a higher categorical agreement (CA, 95.1%) with standard BMD and fewer categorization errors compared to the commercial MH-agar plates (CA BioMérieux 91.1%, Liofilchem 89.2%). E-test on ID-MH-agar plates exhibited a significantly higher essential agreement (EA, 75%) with standard BMD compared to the two MH-agar plates (EA BioMérieux 57%, Liofilchem 44%), and showed a higher performance in detecting high-level resistance than ComASP and UMIC (mean log2 difference with standard BMD for resistant isolates of 0.5, 2.83, and 2.08, respectively). In conclusion, DD and E-test on ID-MH-agar plates exhibit a higher diagnostic performance than on MH-agar plates and the commercial BMD methods. Therefore, we recommend using ID-MH-agar plates for cefiderocol susceptibility testing of A. baumannii.
format Online
Article
Text
id pubmed-10376138
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103761382023-07-29 Comparison of Disk Diffusion, E-Test, and Broth Microdilution Methods for Testing In Vitro Activity of Cefiderocol in Acinetobacter baumannii Kolesnik-Goldmann, Natalia Seth-Smith, Helena M. B. Haldimann, Klara Imkamp, Frank Roloff, Tim Zbinden, Reinhard Hobbie, Sven N. Egli, Adrian Mancini, Stefano Antibiotics (Basel) Article The reference method for cefiderocol antimicrobial susceptibility testing is broth microdilution (BMD) with iron-depleted-Mueller-Hinton (ID-MH) medium, whereas breakpoints recommended for disk diffusion (DD) are based on MH-agar plates. We aimed to compare the performance of the commercial BMD tests ComASP (Liofilchem) and UMIC (Bruker), and DD and E-test using MH- and ID-MH-agar plates with the reference BMD method using 100 carbapenem-resistant-A. baumannii isolates. Standard BMD was performed according to the EUCAST guidelines; DD and E-test were carried out using two commercial MH-agar plates (BioMérieux and Liofilchem) and an in-house ID-MH-agar plate, while ComASP and UMIC were performed according to the manufacturer’s guidelines. DD performed with the ID-MH-agar plates led to a higher categorical agreement (CA, 95.1%) with standard BMD and fewer categorization errors compared to the commercial MH-agar plates (CA BioMérieux 91.1%, Liofilchem 89.2%). E-test on ID-MH-agar plates exhibited a significantly higher essential agreement (EA, 75%) with standard BMD compared to the two MH-agar plates (EA BioMérieux 57%, Liofilchem 44%), and showed a higher performance in detecting high-level resistance than ComASP and UMIC (mean log2 difference with standard BMD for resistant isolates of 0.5, 2.83, and 2.08, respectively). In conclusion, DD and E-test on ID-MH-agar plates exhibit a higher diagnostic performance than on MH-agar plates and the commercial BMD methods. Therefore, we recommend using ID-MH-agar plates for cefiderocol susceptibility testing of A. baumannii. MDPI 2023-07-20 /pmc/articles/PMC10376138/ /pubmed/37508308 http://dx.doi.org/10.3390/antibiotics12071212 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kolesnik-Goldmann, Natalia
Seth-Smith, Helena M. B.
Haldimann, Klara
Imkamp, Frank
Roloff, Tim
Zbinden, Reinhard
Hobbie, Sven N.
Egli, Adrian
Mancini, Stefano
Comparison of Disk Diffusion, E-Test, and Broth Microdilution Methods for Testing In Vitro Activity of Cefiderocol in Acinetobacter baumannii
title Comparison of Disk Diffusion, E-Test, and Broth Microdilution Methods for Testing In Vitro Activity of Cefiderocol in Acinetobacter baumannii
title_full Comparison of Disk Diffusion, E-Test, and Broth Microdilution Methods for Testing In Vitro Activity of Cefiderocol in Acinetobacter baumannii
title_fullStr Comparison of Disk Diffusion, E-Test, and Broth Microdilution Methods for Testing In Vitro Activity of Cefiderocol in Acinetobacter baumannii
title_full_unstemmed Comparison of Disk Diffusion, E-Test, and Broth Microdilution Methods for Testing In Vitro Activity of Cefiderocol in Acinetobacter baumannii
title_short Comparison of Disk Diffusion, E-Test, and Broth Microdilution Methods for Testing In Vitro Activity of Cefiderocol in Acinetobacter baumannii
title_sort comparison of disk diffusion, e-test, and broth microdilution methods for testing in vitro activity of cefiderocol in acinetobacter baumannii
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10376138/
https://www.ncbi.nlm.nih.gov/pubmed/37508308
http://dx.doi.org/10.3390/antibiotics12071212
work_keys_str_mv AT kolesnikgoldmannnatalia comparisonofdiskdiffusionetestandbrothmicrodilutionmethodsfortestinginvitroactivityofcefiderocolinacinetobacterbaumannii
AT sethsmithhelenamb comparisonofdiskdiffusionetestandbrothmicrodilutionmethodsfortestinginvitroactivityofcefiderocolinacinetobacterbaumannii
AT haldimannklara comparisonofdiskdiffusionetestandbrothmicrodilutionmethodsfortestinginvitroactivityofcefiderocolinacinetobacterbaumannii
AT imkampfrank comparisonofdiskdiffusionetestandbrothmicrodilutionmethodsfortestinginvitroactivityofcefiderocolinacinetobacterbaumannii
AT rolofftim comparisonofdiskdiffusionetestandbrothmicrodilutionmethodsfortestinginvitroactivityofcefiderocolinacinetobacterbaumannii
AT zbindenreinhard comparisonofdiskdiffusionetestandbrothmicrodilutionmethodsfortestinginvitroactivityofcefiderocolinacinetobacterbaumannii
AT hobbiesvenn comparisonofdiskdiffusionetestandbrothmicrodilutionmethodsfortestinginvitroactivityofcefiderocolinacinetobacterbaumannii
AT egliadrian comparisonofdiskdiffusionetestandbrothmicrodilutionmethodsfortestinginvitroactivityofcefiderocolinacinetobacterbaumannii
AT mancinistefano comparisonofdiskdiffusionetestandbrothmicrodilutionmethodsfortestinginvitroactivityofcefiderocolinacinetobacterbaumannii