Cargando…
Comparison of Disk Diffusion, E-Test, and Broth Microdilution Methods for Testing In Vitro Activity of Cefiderocol in Acinetobacter baumannii
The reference method for cefiderocol antimicrobial susceptibility testing is broth microdilution (BMD) with iron-depleted-Mueller-Hinton (ID-MH) medium, whereas breakpoints recommended for disk diffusion (DD) are based on MH-agar plates. We aimed to compare the performance of the commercial BMD test...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10376138/ https://www.ncbi.nlm.nih.gov/pubmed/37508308 http://dx.doi.org/10.3390/antibiotics12071212 |
_version_ | 1785079196540731392 |
---|---|
author | Kolesnik-Goldmann, Natalia Seth-Smith, Helena M. B. Haldimann, Klara Imkamp, Frank Roloff, Tim Zbinden, Reinhard Hobbie, Sven N. Egli, Adrian Mancini, Stefano |
author_facet | Kolesnik-Goldmann, Natalia Seth-Smith, Helena M. B. Haldimann, Klara Imkamp, Frank Roloff, Tim Zbinden, Reinhard Hobbie, Sven N. Egli, Adrian Mancini, Stefano |
author_sort | Kolesnik-Goldmann, Natalia |
collection | PubMed |
description | The reference method for cefiderocol antimicrobial susceptibility testing is broth microdilution (BMD) with iron-depleted-Mueller-Hinton (ID-MH) medium, whereas breakpoints recommended for disk diffusion (DD) are based on MH-agar plates. We aimed to compare the performance of the commercial BMD tests ComASP (Liofilchem) and UMIC (Bruker), and DD and E-test using MH- and ID-MH-agar plates with the reference BMD method using 100 carbapenem-resistant-A. baumannii isolates. Standard BMD was performed according to the EUCAST guidelines; DD and E-test were carried out using two commercial MH-agar plates (BioMérieux and Liofilchem) and an in-house ID-MH-agar plate, while ComASP and UMIC were performed according to the manufacturer’s guidelines. DD performed with the ID-MH-agar plates led to a higher categorical agreement (CA, 95.1%) with standard BMD and fewer categorization errors compared to the commercial MH-agar plates (CA BioMérieux 91.1%, Liofilchem 89.2%). E-test on ID-MH-agar plates exhibited a significantly higher essential agreement (EA, 75%) with standard BMD compared to the two MH-agar plates (EA BioMérieux 57%, Liofilchem 44%), and showed a higher performance in detecting high-level resistance than ComASP and UMIC (mean log2 difference with standard BMD for resistant isolates of 0.5, 2.83, and 2.08, respectively). In conclusion, DD and E-test on ID-MH-agar plates exhibit a higher diagnostic performance than on MH-agar plates and the commercial BMD methods. Therefore, we recommend using ID-MH-agar plates for cefiderocol susceptibility testing of A. baumannii. |
format | Online Article Text |
id | pubmed-10376138 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-103761382023-07-29 Comparison of Disk Diffusion, E-Test, and Broth Microdilution Methods for Testing In Vitro Activity of Cefiderocol in Acinetobacter baumannii Kolesnik-Goldmann, Natalia Seth-Smith, Helena M. B. Haldimann, Klara Imkamp, Frank Roloff, Tim Zbinden, Reinhard Hobbie, Sven N. Egli, Adrian Mancini, Stefano Antibiotics (Basel) Article The reference method for cefiderocol antimicrobial susceptibility testing is broth microdilution (BMD) with iron-depleted-Mueller-Hinton (ID-MH) medium, whereas breakpoints recommended for disk diffusion (DD) are based on MH-agar plates. We aimed to compare the performance of the commercial BMD tests ComASP (Liofilchem) and UMIC (Bruker), and DD and E-test using MH- and ID-MH-agar plates with the reference BMD method using 100 carbapenem-resistant-A. baumannii isolates. Standard BMD was performed according to the EUCAST guidelines; DD and E-test were carried out using two commercial MH-agar plates (BioMérieux and Liofilchem) and an in-house ID-MH-agar plate, while ComASP and UMIC were performed according to the manufacturer’s guidelines. DD performed with the ID-MH-agar plates led to a higher categorical agreement (CA, 95.1%) with standard BMD and fewer categorization errors compared to the commercial MH-agar plates (CA BioMérieux 91.1%, Liofilchem 89.2%). E-test on ID-MH-agar plates exhibited a significantly higher essential agreement (EA, 75%) with standard BMD compared to the two MH-agar plates (EA BioMérieux 57%, Liofilchem 44%), and showed a higher performance in detecting high-level resistance than ComASP and UMIC (mean log2 difference with standard BMD for resistant isolates of 0.5, 2.83, and 2.08, respectively). In conclusion, DD and E-test on ID-MH-agar plates exhibit a higher diagnostic performance than on MH-agar plates and the commercial BMD methods. Therefore, we recommend using ID-MH-agar plates for cefiderocol susceptibility testing of A. baumannii. MDPI 2023-07-20 /pmc/articles/PMC10376138/ /pubmed/37508308 http://dx.doi.org/10.3390/antibiotics12071212 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kolesnik-Goldmann, Natalia Seth-Smith, Helena M. B. Haldimann, Klara Imkamp, Frank Roloff, Tim Zbinden, Reinhard Hobbie, Sven N. Egli, Adrian Mancini, Stefano Comparison of Disk Diffusion, E-Test, and Broth Microdilution Methods for Testing In Vitro Activity of Cefiderocol in Acinetobacter baumannii |
title | Comparison of Disk Diffusion, E-Test, and Broth Microdilution Methods for Testing In Vitro Activity of Cefiderocol in Acinetobacter baumannii |
title_full | Comparison of Disk Diffusion, E-Test, and Broth Microdilution Methods for Testing In Vitro Activity of Cefiderocol in Acinetobacter baumannii |
title_fullStr | Comparison of Disk Diffusion, E-Test, and Broth Microdilution Methods for Testing In Vitro Activity of Cefiderocol in Acinetobacter baumannii |
title_full_unstemmed | Comparison of Disk Diffusion, E-Test, and Broth Microdilution Methods for Testing In Vitro Activity of Cefiderocol in Acinetobacter baumannii |
title_short | Comparison of Disk Diffusion, E-Test, and Broth Microdilution Methods for Testing In Vitro Activity of Cefiderocol in Acinetobacter baumannii |
title_sort | comparison of disk diffusion, e-test, and broth microdilution methods for testing in vitro activity of cefiderocol in acinetobacter baumannii |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10376138/ https://www.ncbi.nlm.nih.gov/pubmed/37508308 http://dx.doi.org/10.3390/antibiotics12071212 |
work_keys_str_mv | AT kolesnikgoldmannnatalia comparisonofdiskdiffusionetestandbrothmicrodilutionmethodsfortestinginvitroactivityofcefiderocolinacinetobacterbaumannii AT sethsmithhelenamb comparisonofdiskdiffusionetestandbrothmicrodilutionmethodsfortestinginvitroactivityofcefiderocolinacinetobacterbaumannii AT haldimannklara comparisonofdiskdiffusionetestandbrothmicrodilutionmethodsfortestinginvitroactivityofcefiderocolinacinetobacterbaumannii AT imkampfrank comparisonofdiskdiffusionetestandbrothmicrodilutionmethodsfortestinginvitroactivityofcefiderocolinacinetobacterbaumannii AT rolofftim comparisonofdiskdiffusionetestandbrothmicrodilutionmethodsfortestinginvitroactivityofcefiderocolinacinetobacterbaumannii AT zbindenreinhard comparisonofdiskdiffusionetestandbrothmicrodilutionmethodsfortestinginvitroactivityofcefiderocolinacinetobacterbaumannii AT hobbiesvenn comparisonofdiskdiffusionetestandbrothmicrodilutionmethodsfortestinginvitroactivityofcefiderocolinacinetobacterbaumannii AT egliadrian comparisonofdiskdiffusionetestandbrothmicrodilutionmethodsfortestinginvitroactivityofcefiderocolinacinetobacterbaumannii AT mancinistefano comparisonofdiskdiffusionetestandbrothmicrodilutionmethodsfortestinginvitroactivityofcefiderocolinacinetobacterbaumannii |