Cargando…

The Reliability of Three-Dimensional Landmark-Based Craniomaxillofacial and Airway Cephalometric Analysis

Cephalometric analysis is a standard diagnostic tool in orthodontics and craniofacial surgery. Today, as conventional 2D cephalometry is limited and susceptible to analysis bias, a more reliable and user-friendly three-dimensional system that includes hard tissue, soft tissue, and airways is demande...

Descripción completa

Detalles Bibliográficos
Autores principales: Yao, Kan, Xie, Yilun, Xia, Liang, Wei, Silong, Yu, Wenwen, Shen, Guofang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10377994/
https://www.ncbi.nlm.nih.gov/pubmed/37510103
http://dx.doi.org/10.3390/diagnostics13142360
_version_ 1785079655672315904
author Yao, Kan
Xie, Yilun
Xia, Liang
Wei, Silong
Yu, Wenwen
Shen, Guofang
author_facet Yao, Kan
Xie, Yilun
Xia, Liang
Wei, Silong
Yu, Wenwen
Shen, Guofang
author_sort Yao, Kan
collection PubMed
description Cephalometric analysis is a standard diagnostic tool in orthodontics and craniofacial surgery. Today, as conventional 2D cephalometry is limited and susceptible to analysis bias, a more reliable and user-friendly three-dimensional system that includes hard tissue, soft tissue, and airways is demanded in clinical practice. We launched our study to develop such a system based on CT data and landmarks. This study aims to determine whether the data labeled through our process is highly qualified and whether the soft tissue and airway data derived from CT scans are reliable. We enrolled 15 patients (seven males, eight females, 26.47 ± 3.44 years old) diagnosed with either non-syndromic dento–maxillofacial deformities or OSDB in this study to evaluate the intra- and inter-examiner reliability of our system. A total of 126 landmarks were adopted and divided into five sets by region: 28 cranial points, 25 mandibular points, 20 teeth points, 48 soft tissue points, and 6 airway points. All the landmarks were labeled by two experienced clinical practitioners, either of whom had labeled all the data twice at least one month apart. Furthermore, 78 parameters of three sets were calculated in this study: 42 skeletal parameters (23 angular and 19 linear), 27 soft tissue parameters (9 angular and 18 linear), and 9 upper airway parameters (2 linear, 4 areal, and 3 voluminal). Intraclass correlation coefficient (ICC) was used to evaluate the inter-examiner and intra-examiner reliability of landmark coordinate values and measurement parameters. The overwhelming majority of the landmarks showed excellent intra- and inter-examiner reliability. For skeletal parameters, angular parameters indicated better reliability, while linear parameters performed better for soft tissue parameters. The intra- and inter-examiner ICCs of airway parameters referred to excellent reliability. In summary, the data labeled through our process are qualified, and the soft tissue and airway data derived from CT scans are reliable. Landmarks that are not commonly used in clinical practice may require additional attention while labeling as they are prone to poor reliability. Measurement parameters with values close to 0 tend to have low reliability. We believe this three-dimensional cephalometric system would reach clinical application.
format Online
Article
Text
id pubmed-10377994
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103779942023-07-29 The Reliability of Three-Dimensional Landmark-Based Craniomaxillofacial and Airway Cephalometric Analysis Yao, Kan Xie, Yilun Xia, Liang Wei, Silong Yu, Wenwen Shen, Guofang Diagnostics (Basel) Article Cephalometric analysis is a standard diagnostic tool in orthodontics and craniofacial surgery. Today, as conventional 2D cephalometry is limited and susceptible to analysis bias, a more reliable and user-friendly three-dimensional system that includes hard tissue, soft tissue, and airways is demanded in clinical practice. We launched our study to develop such a system based on CT data and landmarks. This study aims to determine whether the data labeled through our process is highly qualified and whether the soft tissue and airway data derived from CT scans are reliable. We enrolled 15 patients (seven males, eight females, 26.47 ± 3.44 years old) diagnosed with either non-syndromic dento–maxillofacial deformities or OSDB in this study to evaluate the intra- and inter-examiner reliability of our system. A total of 126 landmarks were adopted and divided into five sets by region: 28 cranial points, 25 mandibular points, 20 teeth points, 48 soft tissue points, and 6 airway points. All the landmarks were labeled by two experienced clinical practitioners, either of whom had labeled all the data twice at least one month apart. Furthermore, 78 parameters of three sets were calculated in this study: 42 skeletal parameters (23 angular and 19 linear), 27 soft tissue parameters (9 angular and 18 linear), and 9 upper airway parameters (2 linear, 4 areal, and 3 voluminal). Intraclass correlation coefficient (ICC) was used to evaluate the inter-examiner and intra-examiner reliability of landmark coordinate values and measurement parameters. The overwhelming majority of the landmarks showed excellent intra- and inter-examiner reliability. For skeletal parameters, angular parameters indicated better reliability, while linear parameters performed better for soft tissue parameters. The intra- and inter-examiner ICCs of airway parameters referred to excellent reliability. In summary, the data labeled through our process are qualified, and the soft tissue and airway data derived from CT scans are reliable. Landmarks that are not commonly used in clinical practice may require additional attention while labeling as they are prone to poor reliability. Measurement parameters with values close to 0 tend to have low reliability. We believe this three-dimensional cephalometric system would reach clinical application. MDPI 2023-07-13 /pmc/articles/PMC10377994/ /pubmed/37510103 http://dx.doi.org/10.3390/diagnostics13142360 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Yao, Kan
Xie, Yilun
Xia, Liang
Wei, Silong
Yu, Wenwen
Shen, Guofang
The Reliability of Three-Dimensional Landmark-Based Craniomaxillofacial and Airway Cephalometric Analysis
title The Reliability of Three-Dimensional Landmark-Based Craniomaxillofacial and Airway Cephalometric Analysis
title_full The Reliability of Three-Dimensional Landmark-Based Craniomaxillofacial and Airway Cephalometric Analysis
title_fullStr The Reliability of Three-Dimensional Landmark-Based Craniomaxillofacial and Airway Cephalometric Analysis
title_full_unstemmed The Reliability of Three-Dimensional Landmark-Based Craniomaxillofacial and Airway Cephalometric Analysis
title_short The Reliability of Three-Dimensional Landmark-Based Craniomaxillofacial and Airway Cephalometric Analysis
title_sort reliability of three-dimensional landmark-based craniomaxillofacial and airway cephalometric analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10377994/
https://www.ncbi.nlm.nih.gov/pubmed/37510103
http://dx.doi.org/10.3390/diagnostics13142360
work_keys_str_mv AT yaokan thereliabilityofthreedimensionallandmarkbasedcraniomaxillofacialandairwaycephalometricanalysis
AT xieyilun thereliabilityofthreedimensionallandmarkbasedcraniomaxillofacialandairwaycephalometricanalysis
AT xialiang thereliabilityofthreedimensionallandmarkbasedcraniomaxillofacialandairwaycephalometricanalysis
AT weisilong thereliabilityofthreedimensionallandmarkbasedcraniomaxillofacialandairwaycephalometricanalysis
AT yuwenwen thereliabilityofthreedimensionallandmarkbasedcraniomaxillofacialandairwaycephalometricanalysis
AT shenguofang thereliabilityofthreedimensionallandmarkbasedcraniomaxillofacialandairwaycephalometricanalysis
AT yaokan reliabilityofthreedimensionallandmarkbasedcraniomaxillofacialandairwaycephalometricanalysis
AT xieyilun reliabilityofthreedimensionallandmarkbasedcraniomaxillofacialandairwaycephalometricanalysis
AT xialiang reliabilityofthreedimensionallandmarkbasedcraniomaxillofacialandairwaycephalometricanalysis
AT weisilong reliabilityofthreedimensionallandmarkbasedcraniomaxillofacialandairwaycephalometricanalysis
AT yuwenwen reliabilityofthreedimensionallandmarkbasedcraniomaxillofacialandairwaycephalometricanalysis
AT shenguofang reliabilityofthreedimensionallandmarkbasedcraniomaxillofacialandairwaycephalometricanalysis