Reliability and agreement in intrapartum fetal heart rate monitoring interpretation: A systematic review

INTRODUCTION: Fetal heart rate (FHR) monitoring is routine in intrapartum care worldwide and one of the most common obstetrical procedures. Intrapartum FHR monitoring helps assess fetal wellbeing and interpretation of the FHR help form decisions for clinical management and intervention. It relies on...

Descripción completa

Detalles Bibliográficos
Autores principales: Hernandez Engelhart, Christina, Gundro Brurberg, Kjetil, Aanstad, Kristin Jerve, Pay, Aase Serine Devold, Kaasen, Anne, Blix, Ellen, Vanbelle, Sophie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10378030/
https://www.ncbi.nlm.nih.gov/pubmed/37310765
http://dx.doi.org/10.1111/aogs.14591
_version_ 1785079664828481536
author Hernandez Engelhart, Christina
Gundro Brurberg, Kjetil
Aanstad, Kristin Jerve
Pay, Aase Serine Devold
Kaasen, Anne
Blix, Ellen
Vanbelle, Sophie
author_facet Hernandez Engelhart, Christina
Gundro Brurberg, Kjetil
Aanstad, Kristin Jerve
Pay, Aase Serine Devold
Kaasen, Anne
Blix, Ellen
Vanbelle, Sophie
author_sort Hernandez Engelhart, Christina
collection PubMed
description INTRODUCTION: Fetal heart rate (FHR) monitoring is routine in intrapartum care worldwide and one of the most common obstetrical procedures. Intrapartum FHR monitoring helps assess fetal wellbeing and interpretation of the FHR help form decisions for clinical management and intervention. It relies on the observers' subjective assessments, with variation in interpretations leading to variations in intrapartum care. The purpose of this systematic review was to summarize and evaluate extant inter‐ and intrarater reliability research on the human interpretation of intrapartum FHR monitoring. MATERIAL AND METHODS: We searched for the terms “fetal heart rate monitoring,” “interpretation agreement” and related concepts on Embase, Medline, Maternity and Infant Care Database and CINAHL. The last search was made on January 31, 2022. The protocol for the study was prospectively registered in PROSPERO (CRD42021260937). Studies that assess inter‐ and intrarater reliability and agreement of health professionals' intrapartum FHR monitoring were included and studies including other assessment of fetal wellbeing excluded. We extracted data in reviewer pairs using quality appraisal tool for studies of diagnostic reliability (QAREL) forms. The data retrieved from the studies are presented as narrative synthesis and in additional tables. RESULTS: Forty‐nine articles concerning continuous FHR monitoring were included in the study. For interrater reliability and agreement, in total 577 raters assessed 6315 CTG tracings. There was considerable heterogeneity in quality and measures across the included articles. We found higher reliability and agreement for the basic FHR features than for overall classification and higher agreement for intrarater reliability and agreement than for their interrater counterparts. CONCLUSIONS: There is great variation in reliability and agreement measures for continuous intrapartum FHR monitoring, implying that intrapartum CTG should be used with caution for clinical decision making given its questionable reliability. We found few high‐quality studies and noted methodological concerns in the studies. We recommend a more standardized approach to future reliability studies on FHR monitoring.
format Online
Article
Text
id pubmed-10378030
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-103780302023-07-29 Reliability and agreement in intrapartum fetal heart rate monitoring interpretation: A systematic review Hernandez Engelhart, Christina Gundro Brurberg, Kjetil Aanstad, Kristin Jerve Pay, Aase Serine Devold Kaasen, Anne Blix, Ellen Vanbelle, Sophie Acta Obstet Gynecol Scand Systematic Review INTRODUCTION: Fetal heart rate (FHR) monitoring is routine in intrapartum care worldwide and one of the most common obstetrical procedures. Intrapartum FHR monitoring helps assess fetal wellbeing and interpretation of the FHR help form decisions for clinical management and intervention. It relies on the observers' subjective assessments, with variation in interpretations leading to variations in intrapartum care. The purpose of this systematic review was to summarize and evaluate extant inter‐ and intrarater reliability research on the human interpretation of intrapartum FHR monitoring. MATERIAL AND METHODS: We searched for the terms “fetal heart rate monitoring,” “interpretation agreement” and related concepts on Embase, Medline, Maternity and Infant Care Database and CINAHL. The last search was made on January 31, 2022. The protocol for the study was prospectively registered in PROSPERO (CRD42021260937). Studies that assess inter‐ and intrarater reliability and agreement of health professionals' intrapartum FHR monitoring were included and studies including other assessment of fetal wellbeing excluded. We extracted data in reviewer pairs using quality appraisal tool for studies of diagnostic reliability (QAREL) forms. The data retrieved from the studies are presented as narrative synthesis and in additional tables. RESULTS: Forty‐nine articles concerning continuous FHR monitoring were included in the study. For interrater reliability and agreement, in total 577 raters assessed 6315 CTG tracings. There was considerable heterogeneity in quality and measures across the included articles. We found higher reliability and agreement for the basic FHR features than for overall classification and higher agreement for intrarater reliability and agreement than for their interrater counterparts. CONCLUSIONS: There is great variation in reliability and agreement measures for continuous intrapartum FHR monitoring, implying that intrapartum CTG should be used with caution for clinical decision making given its questionable reliability. We found few high‐quality studies and noted methodological concerns in the studies. We recommend a more standardized approach to future reliability studies on FHR monitoring. John Wiley and Sons Inc. 2023-06-13 /pmc/articles/PMC10378030/ /pubmed/37310765 http://dx.doi.org/10.1111/aogs.14591 Text en © 2023 The Authors. Acta Obstetricia et Gynecologica Scandinavica published by John Wiley & Sons Ltd on behalf of Nordic Federation of Societies of Obstetrics and Gynecology (NFOG). https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Systematic Review
Hernandez Engelhart, Christina
Gundro Brurberg, Kjetil
Aanstad, Kristin Jerve
Pay, Aase Serine Devold
Kaasen, Anne
Blix, Ellen
Vanbelle, Sophie
Reliability and agreement in intrapartum fetal heart rate monitoring interpretation: A systematic review
title Reliability and agreement in intrapartum fetal heart rate monitoring interpretation: A systematic review
title_full Reliability and agreement in intrapartum fetal heart rate monitoring interpretation: A systematic review
title_fullStr Reliability and agreement in intrapartum fetal heart rate monitoring interpretation: A systematic review
title_full_unstemmed Reliability and agreement in intrapartum fetal heart rate monitoring interpretation: A systematic review
title_short Reliability and agreement in intrapartum fetal heart rate monitoring interpretation: A systematic review
title_sort reliability and agreement in intrapartum fetal heart rate monitoring interpretation: a systematic review
topic Systematic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10378030/
https://www.ncbi.nlm.nih.gov/pubmed/37310765
http://dx.doi.org/10.1111/aogs.14591
work_keys_str_mv AT hernandezengelhartchristina reliabilityandagreementinintrapartumfetalheartratemonitoringinterpretationasystematicreview
AT gundrobrurbergkjetil reliabilityandagreementinintrapartumfetalheartratemonitoringinterpretationasystematicreview
AT aanstadkristinjerve reliabilityandagreementinintrapartumfetalheartratemonitoringinterpretationasystematicreview
AT payaaseserinedevold reliabilityandagreementinintrapartumfetalheartratemonitoringinterpretationasystematicreview
AT kaasenanne reliabilityandagreementinintrapartumfetalheartratemonitoringinterpretationasystematicreview
AT blixellen reliabilityandagreementinintrapartumfetalheartratemonitoringinterpretationasystematicreview
AT vanbellesophie reliabilityandagreementinintrapartumfetalheartratemonitoringinterpretationasystematicreview