Cargando…
Faecal Immunochemical Testing to Detect Colorectal Cancer in Symptomatic Patients: A Diagnostic Accuracy Study
(1) Background: NHS England recommended faecal immunochemical testing (FIT) for symptomatic patients in June 2020 to rationalise limited diagnostic services during COVID-19. (2) Aim: to investigate the diagnostic performance of FIT, analysing the proportion of FIT-negative colorectal cancers (CRC) m...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10378039/ https://www.ncbi.nlm.nih.gov/pubmed/37510076 http://dx.doi.org/10.3390/diagnostics13142332 |
Sumario: | (1) Background: NHS England recommended faecal immunochemical testing (FIT) for symptomatic patients in June 2020 to rationalise limited diagnostic services during COVID-19. (2) Aim: to investigate the diagnostic performance of FIT, analysing the proportion of FIT-negative colorectal cancers (CRC) missed in symptomatic patients and how this risk could be mitigated. (3) Design and Setting: a retrospective study of biochemistry and cancer databases involving patients referred from primary healthcare with suspected CRC to a single secondary care trust in North East London. (4) Methods: a retrospective cohort diagnostic accuracy study was undertaken to determine the performance of FIT for detecting CRC at 10 µgHb/g. (5) Results: between January and December 2020, 7653 patients provided a stool sample for FIT analysis; 1679 (22%) samples were excluded due to inadequate or incorrect specimens; 48% of suspected CRC referrals completed FIT before evaluation; 86 FIT tested patients were diagnosed with histologically proven CRC. At 10 µgHb/g, FIT performance was comparable with the existing literature with a sensitivity of 0.8140 (95% CI 0.7189–0.8821), a specificity of 0.7704 (95% CI 0.7595–0.7809), a positive predictive value (PPV) of 0.04923 (95% CI 0.03915–0.06174), a negative predictive value (NPV) of 0.9965 (95% CI 0.9943–0.9978), and a likelihood ratio (LR) of 3.545; 16 patients with CRC had an FIT of ≤10 µgHb/g (18.6% 95% CI 11.0–28.4%). (6) Conclusions: this study raises concerns about compliance with FIT testing and the incidence of FIT-negative CRC at the NICE recommended threshold and how this risk can be mitigated without colonic imaging. Whilst FIT may have facilitated prioritisation during COVID-19, we must be cautious about using FIT alone to determine which patients are referred to secondary care or receive further investigation. |
---|