Cargando…

A Pilot Study Evaluating LV Diastolic Function with M-Mode Measurement of Mitral Valve Movement in the Parasternal Long Axis View

This pilot study aimed to develop a new, reliable, and easy-to-use method for the evaluation of diastolic function through the M-mode measurement of mitral valve (MV) movement in the parasternal long axis (PSLA), similar to E-point septal separation (EPSS) used for systolic function estimation. Thir...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Chan-Ho, Yoon, Hee, Jo, Ik-Joon, Woo, Sookyoung, Heo, Sejin, Chang, Hansol, Lee, Guntak, Park, Jong-Eun, Kim, Taerim, Lee, Se-Uk, Hwang, Sung-Yeon, Cha, Won-Chul, Shin, Tae-Gun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10378499/
https://www.ncbi.nlm.nih.gov/pubmed/37510155
http://dx.doi.org/10.3390/diagnostics13142412
_version_ 1785079781892554752
author Park, Chan-Ho
Yoon, Hee
Jo, Ik-Joon
Woo, Sookyoung
Heo, Sejin
Chang, Hansol
Lee, Guntak
Park, Jong-Eun
Kim, Taerim
Lee, Se-Uk
Hwang, Sung-Yeon
Cha, Won-Chul
Shin, Tae-Gun
author_facet Park, Chan-Ho
Yoon, Hee
Jo, Ik-Joon
Woo, Sookyoung
Heo, Sejin
Chang, Hansol
Lee, Guntak
Park, Jong-Eun
Kim, Taerim
Lee, Se-Uk
Hwang, Sung-Yeon
Cha, Won-Chul
Shin, Tae-Gun
author_sort Park, Chan-Ho
collection PubMed
description This pilot study aimed to develop a new, reliable, and easy-to-use method for the evaluation of diastolic function through the M-mode measurement of mitral valve (MV) movement in the parasternal long axis (PSLA), similar to E-point septal separation (EPSS) used for systolic function estimation. Thirty healthy volunteers from a tertiary emergency department (ED) underwent M-mode measurements of the MV anterior leaflet in the PSLA view. EPSS, A-point septal separation (APSS), A-point opening length (APOL), and E-point opening length (EPOL) were measured in the PSLA view, along with the E and A velocities and e’ velocity in the apical four-chamber view. Correlation analyses were performed to assess the relationship between M-mode and Doppler measurements, and the measurement time was evaluated. No significant correlations were found between M-mode and Doppler measurements in the study. However, M-mode measurements exhibited high reproducibility and faster acquisition, and the EPOL value consistently exceeded the APOL value, resembling the E and A pattern. These findings suggest that visually assessing the M-mode pattern on the MV anterior leaflet in the PSLA view may be a practical approach to estimating diastolic function in the ED. Further investigations with a larger and more diverse patient population are needed to validate these findings.
format Online
Article
Text
id pubmed-10378499
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103784992023-07-29 A Pilot Study Evaluating LV Diastolic Function with M-Mode Measurement of Mitral Valve Movement in the Parasternal Long Axis View Park, Chan-Ho Yoon, Hee Jo, Ik-Joon Woo, Sookyoung Heo, Sejin Chang, Hansol Lee, Guntak Park, Jong-Eun Kim, Taerim Lee, Se-Uk Hwang, Sung-Yeon Cha, Won-Chul Shin, Tae-Gun Diagnostics (Basel) Article This pilot study aimed to develop a new, reliable, and easy-to-use method for the evaluation of diastolic function through the M-mode measurement of mitral valve (MV) movement in the parasternal long axis (PSLA), similar to E-point septal separation (EPSS) used for systolic function estimation. Thirty healthy volunteers from a tertiary emergency department (ED) underwent M-mode measurements of the MV anterior leaflet in the PSLA view. EPSS, A-point septal separation (APSS), A-point opening length (APOL), and E-point opening length (EPOL) were measured in the PSLA view, along with the E and A velocities and e’ velocity in the apical four-chamber view. Correlation analyses were performed to assess the relationship between M-mode and Doppler measurements, and the measurement time was evaluated. No significant correlations were found between M-mode and Doppler measurements in the study. However, M-mode measurements exhibited high reproducibility and faster acquisition, and the EPOL value consistently exceeded the APOL value, resembling the E and A pattern. These findings suggest that visually assessing the M-mode pattern on the MV anterior leaflet in the PSLA view may be a practical approach to estimating diastolic function in the ED. Further investigations with a larger and more diverse patient population are needed to validate these findings. MDPI 2023-07-19 /pmc/articles/PMC10378499/ /pubmed/37510155 http://dx.doi.org/10.3390/diagnostics13142412 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Park, Chan-Ho
Yoon, Hee
Jo, Ik-Joon
Woo, Sookyoung
Heo, Sejin
Chang, Hansol
Lee, Guntak
Park, Jong-Eun
Kim, Taerim
Lee, Se-Uk
Hwang, Sung-Yeon
Cha, Won-Chul
Shin, Tae-Gun
A Pilot Study Evaluating LV Diastolic Function with M-Mode Measurement of Mitral Valve Movement in the Parasternal Long Axis View
title A Pilot Study Evaluating LV Diastolic Function with M-Mode Measurement of Mitral Valve Movement in the Parasternal Long Axis View
title_full A Pilot Study Evaluating LV Diastolic Function with M-Mode Measurement of Mitral Valve Movement in the Parasternal Long Axis View
title_fullStr A Pilot Study Evaluating LV Diastolic Function with M-Mode Measurement of Mitral Valve Movement in the Parasternal Long Axis View
title_full_unstemmed A Pilot Study Evaluating LV Diastolic Function with M-Mode Measurement of Mitral Valve Movement in the Parasternal Long Axis View
title_short A Pilot Study Evaluating LV Diastolic Function with M-Mode Measurement of Mitral Valve Movement in the Parasternal Long Axis View
title_sort pilot study evaluating lv diastolic function with m-mode measurement of mitral valve movement in the parasternal long axis view
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10378499/
https://www.ncbi.nlm.nih.gov/pubmed/37510155
http://dx.doi.org/10.3390/diagnostics13142412
work_keys_str_mv AT parkchanho apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT yoonhee apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT joikjoon apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT woosookyoung apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT heosejin apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT changhansol apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT leeguntak apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT parkjongeun apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT kimtaerim apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT leeseuk apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT hwangsungyeon apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT chawonchul apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT shintaegun apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT parkchanho pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT yoonhee pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT joikjoon pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT woosookyoung pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT heosejin pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT changhansol pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT leeguntak pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT parkjongeun pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT kimtaerim pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT leeseuk pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT hwangsungyeon pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT chawonchul pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview
AT shintaegun pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview