Cargando…
A Pilot Study Evaluating LV Diastolic Function with M-Mode Measurement of Mitral Valve Movement in the Parasternal Long Axis View
This pilot study aimed to develop a new, reliable, and easy-to-use method for the evaluation of diastolic function through the M-mode measurement of mitral valve (MV) movement in the parasternal long axis (PSLA), similar to E-point septal separation (EPSS) used for systolic function estimation. Thir...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10378499/ https://www.ncbi.nlm.nih.gov/pubmed/37510155 http://dx.doi.org/10.3390/diagnostics13142412 |
_version_ | 1785079781892554752 |
---|---|
author | Park, Chan-Ho Yoon, Hee Jo, Ik-Joon Woo, Sookyoung Heo, Sejin Chang, Hansol Lee, Guntak Park, Jong-Eun Kim, Taerim Lee, Se-Uk Hwang, Sung-Yeon Cha, Won-Chul Shin, Tae-Gun |
author_facet | Park, Chan-Ho Yoon, Hee Jo, Ik-Joon Woo, Sookyoung Heo, Sejin Chang, Hansol Lee, Guntak Park, Jong-Eun Kim, Taerim Lee, Se-Uk Hwang, Sung-Yeon Cha, Won-Chul Shin, Tae-Gun |
author_sort | Park, Chan-Ho |
collection | PubMed |
description | This pilot study aimed to develop a new, reliable, and easy-to-use method for the evaluation of diastolic function through the M-mode measurement of mitral valve (MV) movement in the parasternal long axis (PSLA), similar to E-point septal separation (EPSS) used for systolic function estimation. Thirty healthy volunteers from a tertiary emergency department (ED) underwent M-mode measurements of the MV anterior leaflet in the PSLA view. EPSS, A-point septal separation (APSS), A-point opening length (APOL), and E-point opening length (EPOL) were measured in the PSLA view, along with the E and A velocities and e’ velocity in the apical four-chamber view. Correlation analyses were performed to assess the relationship between M-mode and Doppler measurements, and the measurement time was evaluated. No significant correlations were found between M-mode and Doppler measurements in the study. However, M-mode measurements exhibited high reproducibility and faster acquisition, and the EPOL value consistently exceeded the APOL value, resembling the E and A pattern. These findings suggest that visually assessing the M-mode pattern on the MV anterior leaflet in the PSLA view may be a practical approach to estimating diastolic function in the ED. Further investigations with a larger and more diverse patient population are needed to validate these findings. |
format | Online Article Text |
id | pubmed-10378499 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-103784992023-07-29 A Pilot Study Evaluating LV Diastolic Function with M-Mode Measurement of Mitral Valve Movement in the Parasternal Long Axis View Park, Chan-Ho Yoon, Hee Jo, Ik-Joon Woo, Sookyoung Heo, Sejin Chang, Hansol Lee, Guntak Park, Jong-Eun Kim, Taerim Lee, Se-Uk Hwang, Sung-Yeon Cha, Won-Chul Shin, Tae-Gun Diagnostics (Basel) Article This pilot study aimed to develop a new, reliable, and easy-to-use method for the evaluation of diastolic function through the M-mode measurement of mitral valve (MV) movement in the parasternal long axis (PSLA), similar to E-point septal separation (EPSS) used for systolic function estimation. Thirty healthy volunteers from a tertiary emergency department (ED) underwent M-mode measurements of the MV anterior leaflet in the PSLA view. EPSS, A-point septal separation (APSS), A-point opening length (APOL), and E-point opening length (EPOL) were measured in the PSLA view, along with the E and A velocities and e’ velocity in the apical four-chamber view. Correlation analyses were performed to assess the relationship between M-mode and Doppler measurements, and the measurement time was evaluated. No significant correlations were found between M-mode and Doppler measurements in the study. However, M-mode measurements exhibited high reproducibility and faster acquisition, and the EPOL value consistently exceeded the APOL value, resembling the E and A pattern. These findings suggest that visually assessing the M-mode pattern on the MV anterior leaflet in the PSLA view may be a practical approach to estimating diastolic function in the ED. Further investigations with a larger and more diverse patient population are needed to validate these findings. MDPI 2023-07-19 /pmc/articles/PMC10378499/ /pubmed/37510155 http://dx.doi.org/10.3390/diagnostics13142412 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Park, Chan-Ho Yoon, Hee Jo, Ik-Joon Woo, Sookyoung Heo, Sejin Chang, Hansol Lee, Guntak Park, Jong-Eun Kim, Taerim Lee, Se-Uk Hwang, Sung-Yeon Cha, Won-Chul Shin, Tae-Gun A Pilot Study Evaluating LV Diastolic Function with M-Mode Measurement of Mitral Valve Movement in the Parasternal Long Axis View |
title | A Pilot Study Evaluating LV Diastolic Function with M-Mode Measurement of Mitral Valve Movement in the Parasternal Long Axis View |
title_full | A Pilot Study Evaluating LV Diastolic Function with M-Mode Measurement of Mitral Valve Movement in the Parasternal Long Axis View |
title_fullStr | A Pilot Study Evaluating LV Diastolic Function with M-Mode Measurement of Mitral Valve Movement in the Parasternal Long Axis View |
title_full_unstemmed | A Pilot Study Evaluating LV Diastolic Function with M-Mode Measurement of Mitral Valve Movement in the Parasternal Long Axis View |
title_short | A Pilot Study Evaluating LV Diastolic Function with M-Mode Measurement of Mitral Valve Movement in the Parasternal Long Axis View |
title_sort | pilot study evaluating lv diastolic function with m-mode measurement of mitral valve movement in the parasternal long axis view |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10378499/ https://www.ncbi.nlm.nih.gov/pubmed/37510155 http://dx.doi.org/10.3390/diagnostics13142412 |
work_keys_str_mv | AT parkchanho apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT yoonhee apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT joikjoon apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT woosookyoung apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT heosejin apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT changhansol apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT leeguntak apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT parkjongeun apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT kimtaerim apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT leeseuk apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT hwangsungyeon apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT chawonchul apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT shintaegun apilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT parkchanho pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT yoonhee pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT joikjoon pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT woosookyoung pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT heosejin pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT changhansol pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT leeguntak pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT parkjongeun pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT kimtaerim pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT leeseuk pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT hwangsungyeon pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT chawonchul pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview AT shintaegun pilotstudyevaluatinglvdiastolicfunctionwithmmodemeasurementofmitralvalvemovementintheparasternallongaxisview |