Cargando…
Corneal Outcomes Following Cataract Surgery Using Ophthalmic Viscosurgical Devices Composed of Chondroitin Sulfate-Hyaluronic Acid: A Systematic Review and Meta-Analysis
BACKGROUND: Ophthalmic viscosurgical devices (OVDs) are commonly used during cataract surgery to protect the corneal endothelium. A systematic literature review and meta-analysis were conducted to assess the clinical evidence of OVDs composed of chondroitin sulfate-hyaluronic acid (CS-HA) versus oth...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10378560/ https://www.ncbi.nlm.nih.gov/pubmed/37521151 http://dx.doi.org/10.2147/OPTH.S419863 |
_version_ | 1785079797600223232 |
---|---|
author | Hsiao, Chia-Wen Cheng, Hang Ghafouri, Rana Ferko, Nicole C Ayres, Brandon D |
author_facet | Hsiao, Chia-Wen Cheng, Hang Ghafouri, Rana Ferko, Nicole C Ayres, Brandon D |
author_sort | Hsiao, Chia-Wen |
collection | PubMed |
description | BACKGROUND: Ophthalmic viscosurgical devices (OVDs) are commonly used during cataract surgery to protect the corneal endothelium. A systematic literature review and meta-analysis were conducted to assess the clinical evidence of OVDs composed of chondroitin sulfate-hyaluronic acid (CS-HA) versus other OVDs in maintaining endothelial cell density (ECD) and corneal thickness (CT). METHODS: MEDLINE and EMBASE databases were searched from 2000 to 2020. Randomized controlled trials (RCTs, N ≥ 20 per group) comparing an OVD containing CS-HA (ie, VISCOAT(®), DuoVisc(®) or DisCoVisc(®)) to any other OVD were included. The identified comparators were limited to the OVDs found in the literature, which included those composed of HA-only or hydroxypropyl methylcellulose (HPMC). Outcomes of focus included changes in ECD (baseline to 3 months) and CT (baseline to 24 hours). Meta-analyses were performed using R software, to assess mean differences (MD) in ECD and CT change between CS-HA OVDs and HA-only or HPMC OVDs. RESULTS: A total of 966 abstracts were screened, and data were extracted from 12 RCTs. Meta-analyses using a random-effects model revealed significantly lower percent (%) decrease in ECD for CS-HA OVDs compared to both HA-only (MD: −4.10%; 95% CI: −5.81 to −2.40; p < 0.0001; 9 studies) and HPMC (MD: −6.47%; 95% CI: −10.41 to −2.52; p = 0.001; 2 studies) products. Similarly, % CT increase was significantly lower with CS-HA than with HA-only OVDs (MD: −3.22%; 95% CI: −6.24% to −0.20%; p = 0.04; 4 studies). However, there were no significant differences when comparing % CT change between CS-HA and HPMC OVDs (MD: 2.65%; 95% CI: −0.43% to 0.95%; p = 0.4; 2 studies). CONCLUSION: CS-HA OVDs lead to less postoperative loss of endothelial cells and may better protect corneal endothelium during cataract surgery, relative to other OVDs. Future randomized studies may be needed to solidify these findings. |
format | Online Article Text |
id | pubmed-10378560 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-103785602023-07-29 Corneal Outcomes Following Cataract Surgery Using Ophthalmic Viscosurgical Devices Composed of Chondroitin Sulfate-Hyaluronic Acid: A Systematic Review and Meta-Analysis Hsiao, Chia-Wen Cheng, Hang Ghafouri, Rana Ferko, Nicole C Ayres, Brandon D Clin Ophthalmol Review BACKGROUND: Ophthalmic viscosurgical devices (OVDs) are commonly used during cataract surgery to protect the corneal endothelium. A systematic literature review and meta-analysis were conducted to assess the clinical evidence of OVDs composed of chondroitin sulfate-hyaluronic acid (CS-HA) versus other OVDs in maintaining endothelial cell density (ECD) and corneal thickness (CT). METHODS: MEDLINE and EMBASE databases were searched from 2000 to 2020. Randomized controlled trials (RCTs, N ≥ 20 per group) comparing an OVD containing CS-HA (ie, VISCOAT(®), DuoVisc(®) or DisCoVisc(®)) to any other OVD were included. The identified comparators were limited to the OVDs found in the literature, which included those composed of HA-only or hydroxypropyl methylcellulose (HPMC). Outcomes of focus included changes in ECD (baseline to 3 months) and CT (baseline to 24 hours). Meta-analyses were performed using R software, to assess mean differences (MD) in ECD and CT change between CS-HA OVDs and HA-only or HPMC OVDs. RESULTS: A total of 966 abstracts were screened, and data were extracted from 12 RCTs. Meta-analyses using a random-effects model revealed significantly lower percent (%) decrease in ECD for CS-HA OVDs compared to both HA-only (MD: −4.10%; 95% CI: −5.81 to −2.40; p < 0.0001; 9 studies) and HPMC (MD: −6.47%; 95% CI: −10.41 to −2.52; p = 0.001; 2 studies) products. Similarly, % CT increase was significantly lower with CS-HA than with HA-only OVDs (MD: −3.22%; 95% CI: −6.24% to −0.20%; p = 0.04; 4 studies). However, there were no significant differences when comparing % CT change between CS-HA and HPMC OVDs (MD: 2.65%; 95% CI: −0.43% to 0.95%; p = 0.4; 2 studies). CONCLUSION: CS-HA OVDs lead to less postoperative loss of endothelial cells and may better protect corneal endothelium during cataract surgery, relative to other OVDs. Future randomized studies may be needed to solidify these findings. Dove 2023-07-24 /pmc/articles/PMC10378560/ /pubmed/37521151 http://dx.doi.org/10.2147/OPTH.S419863 Text en © 2023 Hsiao et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Review Hsiao, Chia-Wen Cheng, Hang Ghafouri, Rana Ferko, Nicole C Ayres, Brandon D Corneal Outcomes Following Cataract Surgery Using Ophthalmic Viscosurgical Devices Composed of Chondroitin Sulfate-Hyaluronic Acid: A Systematic Review and Meta-Analysis |
title | Corneal Outcomes Following Cataract Surgery Using Ophthalmic Viscosurgical Devices Composed of Chondroitin Sulfate-Hyaluronic Acid: A Systematic Review and Meta-Analysis |
title_full | Corneal Outcomes Following Cataract Surgery Using Ophthalmic Viscosurgical Devices Composed of Chondroitin Sulfate-Hyaluronic Acid: A Systematic Review and Meta-Analysis |
title_fullStr | Corneal Outcomes Following Cataract Surgery Using Ophthalmic Viscosurgical Devices Composed of Chondroitin Sulfate-Hyaluronic Acid: A Systematic Review and Meta-Analysis |
title_full_unstemmed | Corneal Outcomes Following Cataract Surgery Using Ophthalmic Viscosurgical Devices Composed of Chondroitin Sulfate-Hyaluronic Acid: A Systematic Review and Meta-Analysis |
title_short | Corneal Outcomes Following Cataract Surgery Using Ophthalmic Viscosurgical Devices Composed of Chondroitin Sulfate-Hyaluronic Acid: A Systematic Review and Meta-Analysis |
title_sort | corneal outcomes following cataract surgery using ophthalmic viscosurgical devices composed of chondroitin sulfate-hyaluronic acid: a systematic review and meta-analysis |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10378560/ https://www.ncbi.nlm.nih.gov/pubmed/37521151 http://dx.doi.org/10.2147/OPTH.S419863 |
work_keys_str_mv | AT hsiaochiawen cornealoutcomesfollowingcataractsurgeryusingophthalmicviscosurgicaldevicescomposedofchondroitinsulfatehyaluronicacidasystematicreviewandmetaanalysis AT chenghang cornealoutcomesfollowingcataractsurgeryusingophthalmicviscosurgicaldevicescomposedofchondroitinsulfatehyaluronicacidasystematicreviewandmetaanalysis AT ghafourirana cornealoutcomesfollowingcataractsurgeryusingophthalmicviscosurgicaldevicescomposedofchondroitinsulfatehyaluronicacidasystematicreviewandmetaanalysis AT ferkonicolec cornealoutcomesfollowingcataractsurgeryusingophthalmicviscosurgicaldevicescomposedofchondroitinsulfatehyaluronicacidasystematicreviewandmetaanalysis AT ayresbrandond cornealoutcomesfollowingcataractsurgeryusingophthalmicviscosurgicaldevicescomposedofchondroitinsulfatehyaluronicacidasystematicreviewandmetaanalysis |