Cargando…

Virtual Non-Contrast Spectral CT in Renal Masses: Is It Time to Discard Conventional Unenhanced Phase?

Dual-layer Dual-Energy CT (dl-DECT) allows one to create virtual non-contrast (VNC) reconstructions from contrast-enhanced CT scans, with a consequent decrease of the radiation dose. This study aims to assess the reliability of VNC for the diagnostic evaluation of renal masses in comparison with tru...

Descripción completa

Detalles Bibliográficos
Autores principales: Bucolo, Giuseppe M., Ascenti, Velio, Barbera, Simone, Fontana, Federico, Aricò, Francesco M., Piacentino, Filippo, Coppola, Andrea, Cicero, Giuseppe, Marino, Maria Adele, Booz, Christian, Vogl, Thomas J., D’Angelo, Tommaso, Venturini, Massimo, Ascenti, Giorgio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10380803/
https://www.ncbi.nlm.nih.gov/pubmed/37510833
http://dx.doi.org/10.3390/jcm12144718
_version_ 1785080285641048064
author Bucolo, Giuseppe M.
Ascenti, Velio
Barbera, Simone
Fontana, Federico
Aricò, Francesco M.
Piacentino, Filippo
Coppola, Andrea
Cicero, Giuseppe
Marino, Maria Adele
Booz, Christian
Vogl, Thomas J.
D’Angelo, Tommaso
Venturini, Massimo
Ascenti, Giorgio
author_facet Bucolo, Giuseppe M.
Ascenti, Velio
Barbera, Simone
Fontana, Federico
Aricò, Francesco M.
Piacentino, Filippo
Coppola, Andrea
Cicero, Giuseppe
Marino, Maria Adele
Booz, Christian
Vogl, Thomas J.
D’Angelo, Tommaso
Venturini, Massimo
Ascenti, Giorgio
author_sort Bucolo, Giuseppe M.
collection PubMed
description Dual-layer Dual-Energy CT (dl-DECT) allows one to create virtual non-contrast (VNC) reconstructions from contrast-enhanced CT scans, with a consequent decrease of the radiation dose. This study aims to assess the reliability of VNC for the diagnostic evaluation of renal masses in comparison with true non-contrast (TNC) images. The study cohort included 100 renal masses in 40 patients who underwent dl-DECT between June and December 2021. Attenuation values and standard deviations were assessed through the drawing of regions of interest on TNC and VNC images reconstructed from corticomedullary and nephrographic phases. A Wilcoxon signed-rank test was performed in order to assess equivalence of data and Spearman’s Rho correlation coefficient to evaluate correlations between each parameter. The diagnostic accuracy of VNC was estimated through the performance of receiver operating characteristic (ROC) curve analysis. Differences between attenuation values were, respectively, 74%, 18%, 5% and 3% (TNC-VNC(cort)), and 74%, 15%, 9% and 2% (TNC-VNC(neph)). The Wilcoxon signed-rank test demonstrated the equivalence of attenuation values between the TNC and VNC images. The diagnostic performance of VNC images in the depiction of kidney simple cysts remains high compared to TNC (VNC(cort)-AUC: 0.896; VNC(neph)-AUC: 0.901, TNC-AUC: 0.903). In conclusion, quantitative analysis of attenuation values showed a strong agreement between VNC and TNC images in the evaluation of renal masses.
format Online
Article
Text
id pubmed-10380803
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103808032023-07-29 Virtual Non-Contrast Spectral CT in Renal Masses: Is It Time to Discard Conventional Unenhanced Phase? Bucolo, Giuseppe M. Ascenti, Velio Barbera, Simone Fontana, Federico Aricò, Francesco M. Piacentino, Filippo Coppola, Andrea Cicero, Giuseppe Marino, Maria Adele Booz, Christian Vogl, Thomas J. D’Angelo, Tommaso Venturini, Massimo Ascenti, Giorgio J Clin Med Article Dual-layer Dual-Energy CT (dl-DECT) allows one to create virtual non-contrast (VNC) reconstructions from contrast-enhanced CT scans, with a consequent decrease of the radiation dose. This study aims to assess the reliability of VNC for the diagnostic evaluation of renal masses in comparison with true non-contrast (TNC) images. The study cohort included 100 renal masses in 40 patients who underwent dl-DECT between June and December 2021. Attenuation values and standard deviations were assessed through the drawing of regions of interest on TNC and VNC images reconstructed from corticomedullary and nephrographic phases. A Wilcoxon signed-rank test was performed in order to assess equivalence of data and Spearman’s Rho correlation coefficient to evaluate correlations between each parameter. The diagnostic accuracy of VNC was estimated through the performance of receiver operating characteristic (ROC) curve analysis. Differences between attenuation values were, respectively, 74%, 18%, 5% and 3% (TNC-VNC(cort)), and 74%, 15%, 9% and 2% (TNC-VNC(neph)). The Wilcoxon signed-rank test demonstrated the equivalence of attenuation values between the TNC and VNC images. The diagnostic performance of VNC images in the depiction of kidney simple cysts remains high compared to TNC (VNC(cort)-AUC: 0.896; VNC(neph)-AUC: 0.901, TNC-AUC: 0.903). In conclusion, quantitative analysis of attenuation values showed a strong agreement between VNC and TNC images in the evaluation of renal masses. MDPI 2023-07-17 /pmc/articles/PMC10380803/ /pubmed/37510833 http://dx.doi.org/10.3390/jcm12144718 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bucolo, Giuseppe M.
Ascenti, Velio
Barbera, Simone
Fontana, Federico
Aricò, Francesco M.
Piacentino, Filippo
Coppola, Andrea
Cicero, Giuseppe
Marino, Maria Adele
Booz, Christian
Vogl, Thomas J.
D’Angelo, Tommaso
Venturini, Massimo
Ascenti, Giorgio
Virtual Non-Contrast Spectral CT in Renal Masses: Is It Time to Discard Conventional Unenhanced Phase?
title Virtual Non-Contrast Spectral CT in Renal Masses: Is It Time to Discard Conventional Unenhanced Phase?
title_full Virtual Non-Contrast Spectral CT in Renal Masses: Is It Time to Discard Conventional Unenhanced Phase?
title_fullStr Virtual Non-Contrast Spectral CT in Renal Masses: Is It Time to Discard Conventional Unenhanced Phase?
title_full_unstemmed Virtual Non-Contrast Spectral CT in Renal Masses: Is It Time to Discard Conventional Unenhanced Phase?
title_short Virtual Non-Contrast Spectral CT in Renal Masses: Is It Time to Discard Conventional Unenhanced Phase?
title_sort virtual non-contrast spectral ct in renal masses: is it time to discard conventional unenhanced phase?
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10380803/
https://www.ncbi.nlm.nih.gov/pubmed/37510833
http://dx.doi.org/10.3390/jcm12144718
work_keys_str_mv AT bucologiuseppem virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase
AT ascentivelio virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase
AT barberasimone virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase
AT fontanafederico virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase
AT aricofrancescom virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase
AT piacentinofilippo virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase
AT coppolaandrea virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase
AT cicerogiuseppe virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase
AT marinomariaadele virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase
AT boozchristian virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase
AT voglthomasj virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase
AT dangelotommaso virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase
AT venturinimassimo virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase
AT ascentigiorgio virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase