Virtual Non-Contrast Spectral CT in Renal Masses: Is It Time to Discard Conventional Unenhanced Phase?
Dual-layer Dual-Energy CT (dl-DECT) allows one to create virtual non-contrast (VNC) reconstructions from contrast-enhanced CT scans, with a consequent decrease of the radiation dose. This study aims to assess the reliability of VNC for the diagnostic evaluation of renal masses in comparison with tru...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10380803/ https://www.ncbi.nlm.nih.gov/pubmed/37510833 http://dx.doi.org/10.3390/jcm12144718 |
_version_ | 1785080285641048064 |
---|---|
author | Bucolo, Giuseppe M. Ascenti, Velio Barbera, Simone Fontana, Federico Aricò, Francesco M. Piacentino, Filippo Coppola, Andrea Cicero, Giuseppe Marino, Maria Adele Booz, Christian Vogl, Thomas J. D’Angelo, Tommaso Venturini, Massimo Ascenti, Giorgio |
author_facet | Bucolo, Giuseppe M. Ascenti, Velio Barbera, Simone Fontana, Federico Aricò, Francesco M. Piacentino, Filippo Coppola, Andrea Cicero, Giuseppe Marino, Maria Adele Booz, Christian Vogl, Thomas J. D’Angelo, Tommaso Venturini, Massimo Ascenti, Giorgio |
author_sort | Bucolo, Giuseppe M. |
collection | PubMed |
description | Dual-layer Dual-Energy CT (dl-DECT) allows one to create virtual non-contrast (VNC) reconstructions from contrast-enhanced CT scans, with a consequent decrease of the radiation dose. This study aims to assess the reliability of VNC for the diagnostic evaluation of renal masses in comparison with true non-contrast (TNC) images. The study cohort included 100 renal masses in 40 patients who underwent dl-DECT between June and December 2021. Attenuation values and standard deviations were assessed through the drawing of regions of interest on TNC and VNC images reconstructed from corticomedullary and nephrographic phases. A Wilcoxon signed-rank test was performed in order to assess equivalence of data and Spearman’s Rho correlation coefficient to evaluate correlations between each parameter. The diagnostic accuracy of VNC was estimated through the performance of receiver operating characteristic (ROC) curve analysis. Differences between attenuation values were, respectively, 74%, 18%, 5% and 3% (TNC-VNC(cort)), and 74%, 15%, 9% and 2% (TNC-VNC(neph)). The Wilcoxon signed-rank test demonstrated the equivalence of attenuation values between the TNC and VNC images. The diagnostic performance of VNC images in the depiction of kidney simple cysts remains high compared to TNC (VNC(cort)-AUC: 0.896; VNC(neph)-AUC: 0.901, TNC-AUC: 0.903). In conclusion, quantitative analysis of attenuation values showed a strong agreement between VNC and TNC images in the evaluation of renal masses. |
format | Online Article Text |
id | pubmed-10380803 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-103808032023-07-29 Virtual Non-Contrast Spectral CT in Renal Masses: Is It Time to Discard Conventional Unenhanced Phase? Bucolo, Giuseppe M. Ascenti, Velio Barbera, Simone Fontana, Federico Aricò, Francesco M. Piacentino, Filippo Coppola, Andrea Cicero, Giuseppe Marino, Maria Adele Booz, Christian Vogl, Thomas J. D’Angelo, Tommaso Venturini, Massimo Ascenti, Giorgio J Clin Med Article Dual-layer Dual-Energy CT (dl-DECT) allows one to create virtual non-contrast (VNC) reconstructions from contrast-enhanced CT scans, with a consequent decrease of the radiation dose. This study aims to assess the reliability of VNC for the diagnostic evaluation of renal masses in comparison with true non-contrast (TNC) images. The study cohort included 100 renal masses in 40 patients who underwent dl-DECT between June and December 2021. Attenuation values and standard deviations were assessed through the drawing of regions of interest on TNC and VNC images reconstructed from corticomedullary and nephrographic phases. A Wilcoxon signed-rank test was performed in order to assess equivalence of data and Spearman’s Rho correlation coefficient to evaluate correlations between each parameter. The diagnostic accuracy of VNC was estimated through the performance of receiver operating characteristic (ROC) curve analysis. Differences between attenuation values were, respectively, 74%, 18%, 5% and 3% (TNC-VNC(cort)), and 74%, 15%, 9% and 2% (TNC-VNC(neph)). The Wilcoxon signed-rank test demonstrated the equivalence of attenuation values between the TNC and VNC images. The diagnostic performance of VNC images in the depiction of kidney simple cysts remains high compared to TNC (VNC(cort)-AUC: 0.896; VNC(neph)-AUC: 0.901, TNC-AUC: 0.903). In conclusion, quantitative analysis of attenuation values showed a strong agreement between VNC and TNC images in the evaluation of renal masses. MDPI 2023-07-17 /pmc/articles/PMC10380803/ /pubmed/37510833 http://dx.doi.org/10.3390/jcm12144718 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Bucolo, Giuseppe M. Ascenti, Velio Barbera, Simone Fontana, Federico Aricò, Francesco M. Piacentino, Filippo Coppola, Andrea Cicero, Giuseppe Marino, Maria Adele Booz, Christian Vogl, Thomas J. D’Angelo, Tommaso Venturini, Massimo Ascenti, Giorgio Virtual Non-Contrast Spectral CT in Renal Masses: Is It Time to Discard Conventional Unenhanced Phase? |
title | Virtual Non-Contrast Spectral CT in Renal Masses: Is It Time to Discard Conventional Unenhanced Phase? |
title_full | Virtual Non-Contrast Spectral CT in Renal Masses: Is It Time to Discard Conventional Unenhanced Phase? |
title_fullStr | Virtual Non-Contrast Spectral CT in Renal Masses: Is It Time to Discard Conventional Unenhanced Phase? |
title_full_unstemmed | Virtual Non-Contrast Spectral CT in Renal Masses: Is It Time to Discard Conventional Unenhanced Phase? |
title_short | Virtual Non-Contrast Spectral CT in Renal Masses: Is It Time to Discard Conventional Unenhanced Phase? |
title_sort | virtual non-contrast spectral ct in renal masses: is it time to discard conventional unenhanced phase? |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10380803/ https://www.ncbi.nlm.nih.gov/pubmed/37510833 http://dx.doi.org/10.3390/jcm12144718 |
work_keys_str_mv | AT bucologiuseppem virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase AT ascentivelio virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase AT barberasimone virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase AT fontanafederico virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase AT aricofrancescom virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase AT piacentinofilippo virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase AT coppolaandrea virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase AT cicerogiuseppe virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase AT marinomariaadele virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase AT boozchristian virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase AT voglthomasj virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase AT dangelotommaso virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase AT venturinimassimo virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase AT ascentigiorgio virtualnoncontrastspectralctinrenalmassesisittimetodiscardconventionalunenhancedphase |