Cargando…
A Comparison of Observational Studies on Subfoveal Choroidal Thickness Measured with OCT according to the Level of Thyroid Eye Disease Activity—Systematic Review and Meta-Analysis
This study aims to systematise subfoveal choroidal thickness (SFCT) measured using optical coherence tomography (OCT) in patients with different severities of thyroid eye disease (TED) compared with healthy subjects. The PubMed, Web of Science and Scopus databases were searched for the following ter...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10380986/ https://www.ncbi.nlm.nih.gov/pubmed/37510836 http://dx.doi.org/10.3390/jcm12144720 |
_version_ | 1785080331336941568 |
---|---|
author | Kowalik-Jagodzińska, Małgorzata Sobol, Maria Turno-Kręcicka, Anna |
author_facet | Kowalik-Jagodzińska, Małgorzata Sobol, Maria Turno-Kręcicka, Anna |
author_sort | Kowalik-Jagodzińska, Małgorzata |
collection | PubMed |
description | This study aims to systematise subfoveal choroidal thickness (SFCT) measured using optical coherence tomography (OCT) in patients with different severities of thyroid eye disease (TED) compared with healthy subjects. The PubMed, Web of Science and Scopus databases were searched for the following terms: ((Graves’ ophthalmopathy) OR (thyroid eye disease) OR (Graves’ orbitopathy) OR (thyroid-associated orbitopathy)) AND (choroidal thickness) AND ((optical coherence tomography) OR (OCT)). The pool of papers was narrowed down to articles published until 31 January 2023 (26, 26 and 96 papers, respectively). Twenty-five (25) articles were taken into consideration, which were original papers and included the choroidal thickness measurements among TED patients in their results. Finally, eight papers were included in the comparative analysis of the SFCT parameter in TED patients and a group of healthy controls, and seven papers in the comparative analysis of the same parameter between active and inactive TED patients. The mean value of the difference between the TED group and the healthy group was 38.79 μm, with a confidence interval (CI) from 0.09 to 77.49 μm (p = 0.0495). The mean difference between the active TED group and inactive TED group was 38.02 μm, with a CI from 8.62 to 67.42 μm (p = 0.0113). All the results were statistically significant. |
format | Online Article Text |
id | pubmed-10380986 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-103809862023-07-29 A Comparison of Observational Studies on Subfoveal Choroidal Thickness Measured with OCT according to the Level of Thyroid Eye Disease Activity—Systematic Review and Meta-Analysis Kowalik-Jagodzińska, Małgorzata Sobol, Maria Turno-Kręcicka, Anna J Clin Med Systematic Review This study aims to systematise subfoveal choroidal thickness (SFCT) measured using optical coherence tomography (OCT) in patients with different severities of thyroid eye disease (TED) compared with healthy subjects. The PubMed, Web of Science and Scopus databases were searched for the following terms: ((Graves’ ophthalmopathy) OR (thyroid eye disease) OR (Graves’ orbitopathy) OR (thyroid-associated orbitopathy)) AND (choroidal thickness) AND ((optical coherence tomography) OR (OCT)). The pool of papers was narrowed down to articles published until 31 January 2023 (26, 26 and 96 papers, respectively). Twenty-five (25) articles were taken into consideration, which were original papers and included the choroidal thickness measurements among TED patients in their results. Finally, eight papers were included in the comparative analysis of the SFCT parameter in TED patients and a group of healthy controls, and seven papers in the comparative analysis of the same parameter between active and inactive TED patients. The mean value of the difference between the TED group and the healthy group was 38.79 μm, with a confidence interval (CI) from 0.09 to 77.49 μm (p = 0.0495). The mean difference between the active TED group and inactive TED group was 38.02 μm, with a CI from 8.62 to 67.42 μm (p = 0.0113). All the results were statistically significant. MDPI 2023-07-17 /pmc/articles/PMC10380986/ /pubmed/37510836 http://dx.doi.org/10.3390/jcm12144720 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Systematic Review Kowalik-Jagodzińska, Małgorzata Sobol, Maria Turno-Kręcicka, Anna A Comparison of Observational Studies on Subfoveal Choroidal Thickness Measured with OCT according to the Level of Thyroid Eye Disease Activity—Systematic Review and Meta-Analysis |
title | A Comparison of Observational Studies on Subfoveal Choroidal Thickness Measured with OCT according to the Level of Thyroid Eye Disease Activity—Systematic Review and Meta-Analysis |
title_full | A Comparison of Observational Studies on Subfoveal Choroidal Thickness Measured with OCT according to the Level of Thyroid Eye Disease Activity—Systematic Review and Meta-Analysis |
title_fullStr | A Comparison of Observational Studies on Subfoveal Choroidal Thickness Measured with OCT according to the Level of Thyroid Eye Disease Activity—Systematic Review and Meta-Analysis |
title_full_unstemmed | A Comparison of Observational Studies on Subfoveal Choroidal Thickness Measured with OCT according to the Level of Thyroid Eye Disease Activity—Systematic Review and Meta-Analysis |
title_short | A Comparison of Observational Studies on Subfoveal Choroidal Thickness Measured with OCT according to the Level of Thyroid Eye Disease Activity—Systematic Review and Meta-Analysis |
title_sort | comparison of observational studies on subfoveal choroidal thickness measured with oct according to the level of thyroid eye disease activity—systematic review and meta-analysis |
topic | Systematic Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10380986/ https://www.ncbi.nlm.nih.gov/pubmed/37510836 http://dx.doi.org/10.3390/jcm12144720 |
work_keys_str_mv | AT kowalikjagodzinskamałgorzata acomparisonofobservationalstudiesonsubfovealchoroidalthicknessmeasuredwithoctaccordingtothelevelofthyroideyediseaseactivitysystematicreviewandmetaanalysis AT sobolmaria acomparisonofobservationalstudiesonsubfovealchoroidalthicknessmeasuredwithoctaccordingtothelevelofthyroideyediseaseactivitysystematicreviewandmetaanalysis AT turnokrecickaanna acomparisonofobservationalstudiesonsubfovealchoroidalthicknessmeasuredwithoctaccordingtothelevelofthyroideyediseaseactivitysystematicreviewandmetaanalysis AT kowalikjagodzinskamałgorzata comparisonofobservationalstudiesonsubfovealchoroidalthicknessmeasuredwithoctaccordingtothelevelofthyroideyediseaseactivitysystematicreviewandmetaanalysis AT sobolmaria comparisonofobservationalstudiesonsubfovealchoroidalthicknessmeasuredwithoctaccordingtothelevelofthyroideyediseaseactivitysystematicreviewandmetaanalysis AT turnokrecickaanna comparisonofobservationalstudiesonsubfovealchoroidalthicknessmeasuredwithoctaccordingtothelevelofthyroideyediseaseactivitysystematicreviewandmetaanalysis |