Cargando…
Advanced Optimization of Surface Characteristics and Material Removal Rate for Biocompatible Ti6Al4V Using WEDM Process with BBD and NSGA II
Machining titanium alloy (Ti6Al4V) used in orthopedic implants via conventional metal cutting processes is challenging due to excessive cutting forces, low surface integrity, and tool wear. To overcome these difficulties and ensure high-quality products, various industries employ wire electrical dis...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10381744/ https://www.ncbi.nlm.nih.gov/pubmed/37512190 http://dx.doi.org/10.3390/ma16144915 |
_version_ | 1785080519673774080 |
---|---|
author | Nagadeepan, Anbazhagan Jayaprakash, Govindarajalu Senthilkumar, Vagheesan |
author_facet | Nagadeepan, Anbazhagan Jayaprakash, Govindarajalu Senthilkumar, Vagheesan |
author_sort | Nagadeepan, Anbazhagan |
collection | PubMed |
description | Machining titanium alloy (Ti6Al4V) used in orthopedic implants via conventional metal cutting processes is challenging due to excessive cutting forces, low surface integrity, and tool wear. To overcome these difficulties and ensure high-quality products, various industries employ wire electrical discharge machining (WEDM) for precise machining of intricate shapes in titanium alloy. The objective is to make WEDM machining parameters as efficient as possible for machining the biocompatible alloy Ti6Al4Vusing Box–Behnken design (BBD) and nondominated sorting genetic algorithm II (NSGA II). A quadratic mathematical model is created to represent the productivity and the quality factor (MRR and surface roughness) in terms of varying input parameters, such as pulse active (T(on)) time, pulse inactive (T(off)) time, peak amplitude (A) current, and applied servo (V) voltage. The established regression models and related prediction plots provide a reliable approach for predicting how the process variables affect the two responses, namely, MRR and SR. The effects of four process variables on both the responses were examined, and the findings revealed that the pulse duration and voltage have a major influence on the rate at which material is removed (MRR), whereas the pulse duration influences quality (SR). The tradeoff between MRR and SR, when significant process factors are included, emphasizes the need for a reliable multi-objective optimization method. The intelligent metaheuristic optimization method named nondominated sorting genetic algorithm II (NSGA II) was utilized to provide pareto optimum solutions in order to achieve high material removal rate (MRR) and low surface roughness (SR). |
format | Online Article Text |
id | pubmed-10381744 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-103817442023-07-29 Advanced Optimization of Surface Characteristics and Material Removal Rate for Biocompatible Ti6Al4V Using WEDM Process with BBD and NSGA II Nagadeepan, Anbazhagan Jayaprakash, Govindarajalu Senthilkumar, Vagheesan Materials (Basel) Article Machining titanium alloy (Ti6Al4V) used in orthopedic implants via conventional metal cutting processes is challenging due to excessive cutting forces, low surface integrity, and tool wear. To overcome these difficulties and ensure high-quality products, various industries employ wire electrical discharge machining (WEDM) for precise machining of intricate shapes in titanium alloy. The objective is to make WEDM machining parameters as efficient as possible for machining the biocompatible alloy Ti6Al4Vusing Box–Behnken design (BBD) and nondominated sorting genetic algorithm II (NSGA II). A quadratic mathematical model is created to represent the productivity and the quality factor (MRR and surface roughness) in terms of varying input parameters, such as pulse active (T(on)) time, pulse inactive (T(off)) time, peak amplitude (A) current, and applied servo (V) voltage. The established regression models and related prediction plots provide a reliable approach for predicting how the process variables affect the two responses, namely, MRR and SR. The effects of four process variables on both the responses were examined, and the findings revealed that the pulse duration and voltage have a major influence on the rate at which material is removed (MRR), whereas the pulse duration influences quality (SR). The tradeoff between MRR and SR, when significant process factors are included, emphasizes the need for a reliable multi-objective optimization method. The intelligent metaheuristic optimization method named nondominated sorting genetic algorithm II (NSGA II) was utilized to provide pareto optimum solutions in order to achieve high material removal rate (MRR) and low surface roughness (SR). MDPI 2023-07-09 /pmc/articles/PMC10381744/ /pubmed/37512190 http://dx.doi.org/10.3390/ma16144915 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Nagadeepan, Anbazhagan Jayaprakash, Govindarajalu Senthilkumar, Vagheesan Advanced Optimization of Surface Characteristics and Material Removal Rate for Biocompatible Ti6Al4V Using WEDM Process with BBD and NSGA II |
title | Advanced Optimization of Surface Characteristics and Material Removal Rate for Biocompatible Ti6Al4V Using WEDM Process with BBD and NSGA II |
title_full | Advanced Optimization of Surface Characteristics and Material Removal Rate for Biocompatible Ti6Al4V Using WEDM Process with BBD and NSGA II |
title_fullStr | Advanced Optimization of Surface Characteristics and Material Removal Rate for Biocompatible Ti6Al4V Using WEDM Process with BBD and NSGA II |
title_full_unstemmed | Advanced Optimization of Surface Characteristics and Material Removal Rate for Biocompatible Ti6Al4V Using WEDM Process with BBD and NSGA II |
title_short | Advanced Optimization of Surface Characteristics and Material Removal Rate for Biocompatible Ti6Al4V Using WEDM Process with BBD and NSGA II |
title_sort | advanced optimization of surface characteristics and material removal rate for biocompatible ti6al4v using wedm process with bbd and nsga ii |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10381744/ https://www.ncbi.nlm.nih.gov/pubmed/37512190 http://dx.doi.org/10.3390/ma16144915 |
work_keys_str_mv | AT nagadeepananbazhagan advancedoptimizationofsurfacecharacteristicsandmaterialremovalrateforbiocompatibleti6al4vusingwedmprocesswithbbdandnsgaii AT jayaprakashgovindarajalu advancedoptimizationofsurfacecharacteristicsandmaterialremovalrateforbiocompatibleti6al4vusingwedmprocesswithbbdandnsgaii AT senthilkumarvagheesan advancedoptimizationofsurfacecharacteristicsandmaterialremovalrateforbiocompatibleti6al4vusingwedmprocesswithbbdandnsgaii |