Predictors of Conduction Disturbances Requiring New Permanent Pacemaker Implantation following Transcatheter Aortic Valve Implantation Using the Evolut Series

(1) Background: Conduction disturbance requiring a new permanent pacemaker (PPM) after transcatheter aortic valve implantation (TAVI) has traditionally been a common complication. New implantation techniques with self-expanding platforms have reportedly reduced the incidence of PPM. We sought to inv...

Descripción completa

Detalles Bibliográficos
Autores principales: Abdelshafy, Mahmoud, Elkoumy, Ahmed, Elzomor, Hesham, Abdelghani, Mohammad, Campbell, Ruth, Kennedy, Ciara, Kenny Gibson, William, Fezzi, Simone, Nolan, Philip, Wagener, Max, Arsang-Jang, Shahram, Mohamed, Sameh K., Mostafa, Mansour, Shawky, Islam, MacNeill, Briain, McInerney, Angela, Mylotte, Darren, Soliman, Osama
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10381756/
https://www.ncbi.nlm.nih.gov/pubmed/37510950
http://dx.doi.org/10.3390/jcm12144835
_version_ 1785080522675847168
author Abdelshafy, Mahmoud
Elkoumy, Ahmed
Elzomor, Hesham
Abdelghani, Mohammad
Campbell, Ruth
Kennedy, Ciara
Kenny Gibson, William
Fezzi, Simone
Nolan, Philip
Wagener, Max
Arsang-Jang, Shahram
Mohamed, Sameh K.
Mostafa, Mansour
Shawky, Islam
MacNeill, Briain
McInerney, Angela
Mylotte, Darren
Soliman, Osama
author_facet Abdelshafy, Mahmoud
Elkoumy, Ahmed
Elzomor, Hesham
Abdelghani, Mohammad
Campbell, Ruth
Kennedy, Ciara
Kenny Gibson, William
Fezzi, Simone
Nolan, Philip
Wagener, Max
Arsang-Jang, Shahram
Mohamed, Sameh K.
Mostafa, Mansour
Shawky, Islam
MacNeill, Briain
McInerney, Angela
Mylotte, Darren
Soliman, Osama
author_sort Abdelshafy, Mahmoud
collection PubMed
description (1) Background: Conduction disturbance requiring a new permanent pacemaker (PPM) after transcatheter aortic valve implantation (TAVI) has traditionally been a common complication. New implantation techniques with self-expanding platforms have reportedly reduced the incidence of PPM. We sought to investigate the predictors of PPM at 30 days after TAVI using Evolut R/PRO/PRO+; (2) Methods: Consecutive patients who underwent TAVI with the Evolut platform between October 2019 and August 2022 at University Hospital Galway, Ireland, were included. Patients who had a prior PPM (n = 10), valve-in-valve procedures (n = 8) or received >1 valve during the index procedure (n = 3) were excluded. Baseline clinical, electrocardiographic (ECG), echocardiographic and multislice computed tomography (MSCT) parameters were analyzed. Pre-TAVI MSCT analysis included membranous septum (MS) length, a semi-quantitative calcification analysis of the aortic valve leaflets, left ventricular outflow tract, and mitral annulus. Furthermore, the implantation depth (ID) was measured from the final aortography. Multivariate binary logistic analysis and receiver operating characteristic (ROC) curve analysis were used to identify independent predictors and the optimal MS and ID cutoff values to predict new PPM requirements, respectively; (3) Results: A total of 129 TAVI patients were included (age = 81.3 ± 5.3 years; 36% female; median EuroSCORE II 3.2 [2.0, 5.4]). Fifteen patients (11.6%) required PPM after 30 days. The patients requiring new PPM at 30 days were more likely to have a lower European System for Cardiac Operative Risk Evaluation II, increased prevalence of right bundle branch block (RBBB) at baseline ECG, have a higher mitral annular calcification severity and have a shorter MS on preprocedural MSCT analysis, and have a ID, as shown on the final aortogram. From the multivariate analysis, pre-TAVI RBBB, MS length, and ID were shown to be predictors of new PPM. An MS length of <2.85 mm (AUC = 0.85, 95%CI: (0.77, 0.93)) and ID of >3.99 mm (area under the curve (AUC) = 0.79, (95% confidence interval (CI): (0.68, 0.90)) were found to be the optimal cut-offs for predicting new PPM requirements; (4) Conclusions: Membranous septum length and implantation depth were found to be independent predictors of new PPM post-TAVI with the Evolut platform. Patient-specific implantation depth could be used to mitigate the requirement for new PPM.
format Online
Article
Text
id pubmed-10381756
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103817562023-07-29 Predictors of Conduction Disturbances Requiring New Permanent Pacemaker Implantation following Transcatheter Aortic Valve Implantation Using the Evolut Series Abdelshafy, Mahmoud Elkoumy, Ahmed Elzomor, Hesham Abdelghani, Mohammad Campbell, Ruth Kennedy, Ciara Kenny Gibson, William Fezzi, Simone Nolan, Philip Wagener, Max Arsang-Jang, Shahram Mohamed, Sameh K. Mostafa, Mansour Shawky, Islam MacNeill, Briain McInerney, Angela Mylotte, Darren Soliman, Osama J Clin Med Article (1) Background: Conduction disturbance requiring a new permanent pacemaker (PPM) after transcatheter aortic valve implantation (TAVI) has traditionally been a common complication. New implantation techniques with self-expanding platforms have reportedly reduced the incidence of PPM. We sought to investigate the predictors of PPM at 30 days after TAVI using Evolut R/PRO/PRO+; (2) Methods: Consecutive patients who underwent TAVI with the Evolut platform between October 2019 and August 2022 at University Hospital Galway, Ireland, were included. Patients who had a prior PPM (n = 10), valve-in-valve procedures (n = 8) or received >1 valve during the index procedure (n = 3) were excluded. Baseline clinical, electrocardiographic (ECG), echocardiographic and multislice computed tomography (MSCT) parameters were analyzed. Pre-TAVI MSCT analysis included membranous septum (MS) length, a semi-quantitative calcification analysis of the aortic valve leaflets, left ventricular outflow tract, and mitral annulus. Furthermore, the implantation depth (ID) was measured from the final aortography. Multivariate binary logistic analysis and receiver operating characteristic (ROC) curve analysis were used to identify independent predictors and the optimal MS and ID cutoff values to predict new PPM requirements, respectively; (3) Results: A total of 129 TAVI patients were included (age = 81.3 ± 5.3 years; 36% female; median EuroSCORE II 3.2 [2.0, 5.4]). Fifteen patients (11.6%) required PPM after 30 days. The patients requiring new PPM at 30 days were more likely to have a lower European System for Cardiac Operative Risk Evaluation II, increased prevalence of right bundle branch block (RBBB) at baseline ECG, have a higher mitral annular calcification severity and have a shorter MS on preprocedural MSCT analysis, and have a ID, as shown on the final aortogram. From the multivariate analysis, pre-TAVI RBBB, MS length, and ID were shown to be predictors of new PPM. An MS length of <2.85 mm (AUC = 0.85, 95%CI: (0.77, 0.93)) and ID of >3.99 mm (area under the curve (AUC) = 0.79, (95% confidence interval (CI): (0.68, 0.90)) were found to be the optimal cut-offs for predicting new PPM requirements; (4) Conclusions: Membranous septum length and implantation depth were found to be independent predictors of new PPM post-TAVI with the Evolut platform. Patient-specific implantation depth could be used to mitigate the requirement for new PPM. MDPI 2023-07-22 /pmc/articles/PMC10381756/ /pubmed/37510950 http://dx.doi.org/10.3390/jcm12144835 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Abdelshafy, Mahmoud
Elkoumy, Ahmed
Elzomor, Hesham
Abdelghani, Mohammad
Campbell, Ruth
Kennedy, Ciara
Kenny Gibson, William
Fezzi, Simone
Nolan, Philip
Wagener, Max
Arsang-Jang, Shahram
Mohamed, Sameh K.
Mostafa, Mansour
Shawky, Islam
MacNeill, Briain
McInerney, Angela
Mylotte, Darren
Soliman, Osama
Predictors of Conduction Disturbances Requiring New Permanent Pacemaker Implantation following Transcatheter Aortic Valve Implantation Using the Evolut Series
title Predictors of Conduction Disturbances Requiring New Permanent Pacemaker Implantation following Transcatheter Aortic Valve Implantation Using the Evolut Series
title_full Predictors of Conduction Disturbances Requiring New Permanent Pacemaker Implantation following Transcatheter Aortic Valve Implantation Using the Evolut Series
title_fullStr Predictors of Conduction Disturbances Requiring New Permanent Pacemaker Implantation following Transcatheter Aortic Valve Implantation Using the Evolut Series
title_full_unstemmed Predictors of Conduction Disturbances Requiring New Permanent Pacemaker Implantation following Transcatheter Aortic Valve Implantation Using the Evolut Series
title_short Predictors of Conduction Disturbances Requiring New Permanent Pacemaker Implantation following Transcatheter Aortic Valve Implantation Using the Evolut Series
title_sort predictors of conduction disturbances requiring new permanent pacemaker implantation following transcatheter aortic valve implantation using the evolut series
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10381756/
https://www.ncbi.nlm.nih.gov/pubmed/37510950
http://dx.doi.org/10.3390/jcm12144835
work_keys_str_mv AT abdelshafymahmoud predictorsofconductiondisturbancesrequiringnewpermanentpacemakerimplantationfollowingtranscatheteraorticvalveimplantationusingtheevolutseries
AT elkoumyahmed predictorsofconductiondisturbancesrequiringnewpermanentpacemakerimplantationfollowingtranscatheteraorticvalveimplantationusingtheevolutseries
AT elzomorhesham predictorsofconductiondisturbancesrequiringnewpermanentpacemakerimplantationfollowingtranscatheteraorticvalveimplantationusingtheevolutseries
AT abdelghanimohammad predictorsofconductiondisturbancesrequiringnewpermanentpacemakerimplantationfollowingtranscatheteraorticvalveimplantationusingtheevolutseries
AT campbellruth predictorsofconductiondisturbancesrequiringnewpermanentpacemakerimplantationfollowingtranscatheteraorticvalveimplantationusingtheevolutseries
AT kennedyciara predictorsofconductiondisturbancesrequiringnewpermanentpacemakerimplantationfollowingtranscatheteraorticvalveimplantationusingtheevolutseries
AT kennygibsonwilliam predictorsofconductiondisturbancesrequiringnewpermanentpacemakerimplantationfollowingtranscatheteraorticvalveimplantationusingtheevolutseries
AT fezzisimone predictorsofconductiondisturbancesrequiringnewpermanentpacemakerimplantationfollowingtranscatheteraorticvalveimplantationusingtheevolutseries
AT nolanphilip predictorsofconductiondisturbancesrequiringnewpermanentpacemakerimplantationfollowingtranscatheteraorticvalveimplantationusingtheevolutseries
AT wagenermax predictorsofconductiondisturbancesrequiringnewpermanentpacemakerimplantationfollowingtranscatheteraorticvalveimplantationusingtheevolutseries
AT arsangjangshahram predictorsofconductiondisturbancesrequiringnewpermanentpacemakerimplantationfollowingtranscatheteraorticvalveimplantationusingtheevolutseries
AT mohamedsamehk predictorsofconductiondisturbancesrequiringnewpermanentpacemakerimplantationfollowingtranscatheteraorticvalveimplantationusingtheevolutseries
AT mostafamansour predictorsofconductiondisturbancesrequiringnewpermanentpacemakerimplantationfollowingtranscatheteraorticvalveimplantationusingtheevolutseries
AT shawkyislam predictorsofconductiondisturbancesrequiringnewpermanentpacemakerimplantationfollowingtranscatheteraorticvalveimplantationusingtheevolutseries
AT macneillbriain predictorsofconductiondisturbancesrequiringnewpermanentpacemakerimplantationfollowingtranscatheteraorticvalveimplantationusingtheevolutseries
AT mcinerneyangela predictorsofconductiondisturbancesrequiringnewpermanentpacemakerimplantationfollowingtranscatheteraorticvalveimplantationusingtheevolutseries
AT mylottedarren predictorsofconductiondisturbancesrequiringnewpermanentpacemakerimplantationfollowingtranscatheteraorticvalveimplantationusingtheevolutseries
AT solimanosama predictorsofconductiondisturbancesrequiringnewpermanentpacemakerimplantationfollowingtranscatheteraorticvalveimplantationusingtheevolutseries