Cargando…

Assessment by Optical Coherence Tomography of Short-Term Changes in IOP-Related Structures Caused by Wearing Scleral Lenses

Background: The mechanism that could increase intraocular pressure (IOP) during scleral lens (SL) wear is not fully understood, although it may be related to compression of the landing zone on structures involved in aqueous humor drainage. Methods: Thirty healthy subjects were fitted with two SLs of...

Descripción completa

Detalles Bibliográficos
Autores principales: Queiruga-Piñeiro, Juan, Barros, Alberto, Lozano-Sanroma, Javier, Fernández-Vega Cueto, Andrés, Rodríguez-Uña, Ignacio, Merayo-LLoves, Jesús
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10381863/
https://www.ncbi.nlm.nih.gov/pubmed/37510907
http://dx.doi.org/10.3390/jcm12144792
_version_ 1785080549168119808
author Queiruga-Piñeiro, Juan
Barros, Alberto
Lozano-Sanroma, Javier
Fernández-Vega Cueto, Andrés
Rodríguez-Uña, Ignacio
Merayo-LLoves, Jesús
author_facet Queiruga-Piñeiro, Juan
Barros, Alberto
Lozano-Sanroma, Javier
Fernández-Vega Cueto, Andrés
Rodríguez-Uña, Ignacio
Merayo-LLoves, Jesús
author_sort Queiruga-Piñeiro, Juan
collection PubMed
description Background: The mechanism that could increase intraocular pressure (IOP) during scleral lens (SL) wear is not fully understood, although it may be related to compression of the landing zone on structures involved in aqueous humor drainage. Methods: Thirty healthy subjects were fitted with two SLs of different sizes (L1 = 15.8 mm, L2 = 16.8 mm) for 2 h in the right eye and left eye as a control. Central corneal thickness (CCT), parameters of iridocorneal angle (ICA), Schlemm’s canal (SC), and optic nerve head were measured before and after wearing both SLs. IOP was measured with a Perkins applanation tonometer before and after lens removal and with a transpalpebral tonometer before, during (0 h, 1 h, and 2 h), and after lens wear. Results: CCT increased after wearing L1 (8.10 ± 4.21 µm; p < 0.01) and L2 (9.17 ± 4.41 µm; p < 0.01). After L1 removal, the ICA parameters decreased significantly (p < 0.05). With L2 removal, nasal and temporal SC area and length were reduced (p < 0.05). An increased IOP with transpalpebral tonometry was observed at 2 h of wearing L1 (2.55 ± 2.04 mmHg; p < 0.01) and L2 (2.53 ± 2.22 mmHg; p < 0.01), as well as an increased IOP with Perkins applanation tonometry after wearing L1 (0.43 ± 1.07 mmHg; p = 0.02). Conclusions: In the short term, SL resulted in a slight increase in IOP in addition to small changes in ICA and SC parameters, although it did not seem to be clinically relevant in healthy subjects.
format Online
Article
Text
id pubmed-10381863
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103818632023-07-29 Assessment by Optical Coherence Tomography of Short-Term Changes in IOP-Related Structures Caused by Wearing Scleral Lenses Queiruga-Piñeiro, Juan Barros, Alberto Lozano-Sanroma, Javier Fernández-Vega Cueto, Andrés Rodríguez-Uña, Ignacio Merayo-LLoves, Jesús J Clin Med Article Background: The mechanism that could increase intraocular pressure (IOP) during scleral lens (SL) wear is not fully understood, although it may be related to compression of the landing zone on structures involved in aqueous humor drainage. Methods: Thirty healthy subjects were fitted with two SLs of different sizes (L1 = 15.8 mm, L2 = 16.8 mm) for 2 h in the right eye and left eye as a control. Central corneal thickness (CCT), parameters of iridocorneal angle (ICA), Schlemm’s canal (SC), and optic nerve head were measured before and after wearing both SLs. IOP was measured with a Perkins applanation tonometer before and after lens removal and with a transpalpebral tonometer before, during (0 h, 1 h, and 2 h), and after lens wear. Results: CCT increased after wearing L1 (8.10 ± 4.21 µm; p < 0.01) and L2 (9.17 ± 4.41 µm; p < 0.01). After L1 removal, the ICA parameters decreased significantly (p < 0.05). With L2 removal, nasal and temporal SC area and length were reduced (p < 0.05). An increased IOP with transpalpebral tonometry was observed at 2 h of wearing L1 (2.55 ± 2.04 mmHg; p < 0.01) and L2 (2.53 ± 2.22 mmHg; p < 0.01), as well as an increased IOP with Perkins applanation tonometry after wearing L1 (0.43 ± 1.07 mmHg; p = 0.02). Conclusions: In the short term, SL resulted in a slight increase in IOP in addition to small changes in ICA and SC parameters, although it did not seem to be clinically relevant in healthy subjects. MDPI 2023-07-20 /pmc/articles/PMC10381863/ /pubmed/37510907 http://dx.doi.org/10.3390/jcm12144792 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Queiruga-Piñeiro, Juan
Barros, Alberto
Lozano-Sanroma, Javier
Fernández-Vega Cueto, Andrés
Rodríguez-Uña, Ignacio
Merayo-LLoves, Jesús
Assessment by Optical Coherence Tomography of Short-Term Changes in IOP-Related Structures Caused by Wearing Scleral Lenses
title Assessment by Optical Coherence Tomography of Short-Term Changes in IOP-Related Structures Caused by Wearing Scleral Lenses
title_full Assessment by Optical Coherence Tomography of Short-Term Changes in IOP-Related Structures Caused by Wearing Scleral Lenses
title_fullStr Assessment by Optical Coherence Tomography of Short-Term Changes in IOP-Related Structures Caused by Wearing Scleral Lenses
title_full_unstemmed Assessment by Optical Coherence Tomography of Short-Term Changes in IOP-Related Structures Caused by Wearing Scleral Lenses
title_short Assessment by Optical Coherence Tomography of Short-Term Changes in IOP-Related Structures Caused by Wearing Scleral Lenses
title_sort assessment by optical coherence tomography of short-term changes in iop-related structures caused by wearing scleral lenses
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10381863/
https://www.ncbi.nlm.nih.gov/pubmed/37510907
http://dx.doi.org/10.3390/jcm12144792
work_keys_str_mv AT queirugapineirojuan assessmentbyopticalcoherencetomographyofshorttermchangesinioprelatedstructurescausedbywearingsclerallenses
AT barrosalberto assessmentbyopticalcoherencetomographyofshorttermchangesinioprelatedstructurescausedbywearingsclerallenses
AT lozanosanromajavier assessmentbyopticalcoherencetomographyofshorttermchangesinioprelatedstructurescausedbywearingsclerallenses
AT fernandezvegacuetoandres assessmentbyopticalcoherencetomographyofshorttermchangesinioprelatedstructurescausedbywearingsclerallenses
AT rodriguezunaignacio assessmentbyopticalcoherencetomographyofshorttermchangesinioprelatedstructurescausedbywearingsclerallenses
AT merayollovesjesus assessmentbyopticalcoherencetomographyofshorttermchangesinioprelatedstructurescausedbywearingsclerallenses