Cargando…

Ultrasound Contrast Agent Priming of Biopsy and Introducer Needles by Using a Small Syringe to Improve Needle Visibility in a Phantom Model

PURPOSE: Biopsy under the guidance of contrast-enhanced ultrasound is sometimes useful. Needle visualization in contrast-specific imaging-mode is often poor; however, it may be improved by priming the needles with an ultrasound contrast agent. This study aimed to evaluate needle priming methods usin...

Descripción completa

Detalles Bibliográficos
Autores principales: Thunswärd, Per, Österberg, Karin, Ahlström, Håkan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10382408/
https://www.ncbi.nlm.nih.gov/pubmed/37438650
http://dx.doi.org/10.1007/s00270-023-03500-3
_version_ 1785080672771112960
author Thunswärd, Per
Österberg, Karin
Ahlström, Håkan
author_facet Thunswärd, Per
Österberg, Karin
Ahlström, Håkan
author_sort Thunswärd, Per
collection PubMed
description PURPOSE: Biopsy under the guidance of contrast-enhanced ultrasound is sometimes useful. Needle visualization in contrast-specific imaging-mode is often poor; however, it may be improved by priming the needles with an ultrasound contrast agent. This study aimed to evaluate needle priming methods using the ultrasound contrast agent sulfur hexafluoride and a 1 mL syringe. MATERIAL AND METHODS: Two kinds of biopsy needles, side-notch and full core, and one kind of introducer needle were primed using non-primed needles as controls (n = 180). Recordings of punctures were performed in a water bath phantom to which the ultrasound contrast agent had also been added. Contrast-specific imaging-mode needle visibility was evaluated for the entire needles and the needle tips, respectively, quantitatively by calculating the contrast-to-noise ratio and qualitatively via grading by three radiologists. RESULTS: The contrast-to-noise ratio following the ultrasound contrast agent priming was superior compared to the controls for the entire needles of all three types (p < 0.001) and for the needle tips of the core biopsy needles and introducer needles (p < 0.001). However, the ratio was equal to the controls for the needle tips of the side-notch biopsy needles (p = 0.19). Needle visibility following the ultrasound contrast agent priming was qualitatively superior compared to the controls for both the entire needles and the needle tips, and the difference was considered clinically relevant by the assessors (p < 0.001). CONCLUSION: The ultrasound contrast agent needle priming methods described increased the contrast-specific imaging-mode needle visibility in a phantom model. Nonetheless, the results also need to be confirmed in vivo. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00270-023-03500-3.
format Online
Article
Text
id pubmed-10382408
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-103824082023-07-30 Ultrasound Contrast Agent Priming of Biopsy and Introducer Needles by Using a Small Syringe to Improve Needle Visibility in a Phantom Model Thunswärd, Per Österberg, Karin Ahlström, Håkan Cardiovasc Intervent Radiol Laboratory Investigation PURPOSE: Biopsy under the guidance of contrast-enhanced ultrasound is sometimes useful. Needle visualization in contrast-specific imaging-mode is often poor; however, it may be improved by priming the needles with an ultrasound contrast agent. This study aimed to evaluate needle priming methods using the ultrasound contrast agent sulfur hexafluoride and a 1 mL syringe. MATERIAL AND METHODS: Two kinds of biopsy needles, side-notch and full core, and one kind of introducer needle were primed using non-primed needles as controls (n = 180). Recordings of punctures were performed in a water bath phantom to which the ultrasound contrast agent had also been added. Contrast-specific imaging-mode needle visibility was evaluated for the entire needles and the needle tips, respectively, quantitatively by calculating the contrast-to-noise ratio and qualitatively via grading by three radiologists. RESULTS: The contrast-to-noise ratio following the ultrasound contrast agent priming was superior compared to the controls for the entire needles of all three types (p < 0.001) and for the needle tips of the core biopsy needles and introducer needles (p < 0.001). However, the ratio was equal to the controls for the needle tips of the side-notch biopsy needles (p = 0.19). Needle visibility following the ultrasound contrast agent priming was qualitatively superior compared to the controls for both the entire needles and the needle tips, and the difference was considered clinically relevant by the assessors (p < 0.001). CONCLUSION: The ultrasound contrast agent needle priming methods described increased the contrast-specific imaging-mode needle visibility in a phantom model. Nonetheless, the results also need to be confirmed in vivo. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00270-023-03500-3. Springer US 2023-07-12 2023 /pmc/articles/PMC10382408/ /pubmed/37438650 http://dx.doi.org/10.1007/s00270-023-03500-3 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Laboratory Investigation
Thunswärd, Per
Österberg, Karin
Ahlström, Håkan
Ultrasound Contrast Agent Priming of Biopsy and Introducer Needles by Using a Small Syringe to Improve Needle Visibility in a Phantom Model
title Ultrasound Contrast Agent Priming of Biopsy and Introducer Needles by Using a Small Syringe to Improve Needle Visibility in a Phantom Model
title_full Ultrasound Contrast Agent Priming of Biopsy and Introducer Needles by Using a Small Syringe to Improve Needle Visibility in a Phantom Model
title_fullStr Ultrasound Contrast Agent Priming of Biopsy and Introducer Needles by Using a Small Syringe to Improve Needle Visibility in a Phantom Model
title_full_unstemmed Ultrasound Contrast Agent Priming of Biopsy and Introducer Needles by Using a Small Syringe to Improve Needle Visibility in a Phantom Model
title_short Ultrasound Contrast Agent Priming of Biopsy and Introducer Needles by Using a Small Syringe to Improve Needle Visibility in a Phantom Model
title_sort ultrasound contrast agent priming of biopsy and introducer needles by using a small syringe to improve needle visibility in a phantom model
topic Laboratory Investigation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10382408/
https://www.ncbi.nlm.nih.gov/pubmed/37438650
http://dx.doi.org/10.1007/s00270-023-03500-3
work_keys_str_mv AT thunswardper ultrasoundcontrastagentprimingofbiopsyandintroducerneedlesbyusingasmallsyringetoimproveneedlevisibilityinaphantommodel
AT osterbergkarin ultrasoundcontrastagentprimingofbiopsyandintroducerneedlesbyusingasmallsyringetoimproveneedlevisibilityinaphantommodel
AT ahlstromhakan ultrasoundcontrastagentprimingofbiopsyandintroducerneedlesbyusingasmallsyringetoimproveneedlevisibilityinaphantommodel