Cargando…
Diffractive Achromat with Freeform Slope for Broadband Imaging over a Long Focal Depth
We propose a method for designing a long-focal-depth diffractive achromat (LFDA). By applying rotational symmetric parameterization, an LFDA with a diameter of 10.89 mm is designed over three wavelengths at six focal planes. The smoothly changed slope designed by the binary variable slope search (BV...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10383085/ https://www.ncbi.nlm.nih.gov/pubmed/37512712 http://dx.doi.org/10.3390/mi14071401 |
_version_ | 1785080820082409472 |
---|---|
author | Yi, Donghui Zhou, Fengbin Hua, Jianyu Chen, Linsen Qiao, Wen |
author_facet | Yi, Donghui Zhou, Fengbin Hua, Jianyu Chen, Linsen Qiao, Wen |
author_sort | Yi, Donghui |
collection | PubMed |
description | We propose a method for designing a long-focal-depth diffractive achromat (LFDA). By applying rotational symmetric parameterization, an LFDA with a diameter of 10.89 mm is designed over three wavelengths at six focal planes. The smoothly changed slope designed by the binary variable slope search (BVSS) algorithm greatly reduces the discontinuity in depth, thus it is a fabrication-friendly process for grayscale laser direct writing lithography, involving less fabrication error and cost. The deviation between the designed and fabricated profiles amounts to 9.68%. The LFDA operates at multiple wavelengths (654 nm, 545 nm, and 467 nm) with a DOF of 500 mm~7.65λ × 10(5) (λ = 654 nm). The simulated and measured full-width at half-maximum (FWHM) of the focused beam is close to the diffraction limit. Experimental studies suggest that the LFDA possesses a superior capability to form high-quality chromatic images in a wide range of depths of field. The LFDA opens a new avenue to achieve compact achromatic systems for imaging, sensing, and 3D display. |
format | Online Article Text |
id | pubmed-10383085 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-103830852023-07-30 Diffractive Achromat with Freeform Slope for Broadband Imaging over a Long Focal Depth Yi, Donghui Zhou, Fengbin Hua, Jianyu Chen, Linsen Qiao, Wen Micromachines (Basel) Article We propose a method for designing a long-focal-depth diffractive achromat (LFDA). By applying rotational symmetric parameterization, an LFDA with a diameter of 10.89 mm is designed over three wavelengths at six focal planes. The smoothly changed slope designed by the binary variable slope search (BVSS) algorithm greatly reduces the discontinuity in depth, thus it is a fabrication-friendly process for grayscale laser direct writing lithography, involving less fabrication error and cost. The deviation between the designed and fabricated profiles amounts to 9.68%. The LFDA operates at multiple wavelengths (654 nm, 545 nm, and 467 nm) with a DOF of 500 mm~7.65λ × 10(5) (λ = 654 nm). The simulated and measured full-width at half-maximum (FWHM) of the focused beam is close to the diffraction limit. Experimental studies suggest that the LFDA possesses a superior capability to form high-quality chromatic images in a wide range of depths of field. The LFDA opens a new avenue to achieve compact achromatic systems for imaging, sensing, and 3D display. MDPI 2023-07-09 /pmc/articles/PMC10383085/ /pubmed/37512712 http://dx.doi.org/10.3390/mi14071401 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Yi, Donghui Zhou, Fengbin Hua, Jianyu Chen, Linsen Qiao, Wen Diffractive Achromat with Freeform Slope for Broadband Imaging over a Long Focal Depth |
title | Diffractive Achromat with Freeform Slope for Broadband Imaging over a Long Focal Depth |
title_full | Diffractive Achromat with Freeform Slope for Broadband Imaging over a Long Focal Depth |
title_fullStr | Diffractive Achromat with Freeform Slope for Broadband Imaging over a Long Focal Depth |
title_full_unstemmed | Diffractive Achromat with Freeform Slope for Broadband Imaging over a Long Focal Depth |
title_short | Diffractive Achromat with Freeform Slope for Broadband Imaging over a Long Focal Depth |
title_sort | diffractive achromat with freeform slope for broadband imaging over a long focal depth |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10383085/ https://www.ncbi.nlm.nih.gov/pubmed/37512712 http://dx.doi.org/10.3390/mi14071401 |
work_keys_str_mv | AT yidonghui diffractiveachromatwithfreeformslopeforbroadbandimagingoveralongfocaldepth AT zhoufengbin diffractiveachromatwithfreeformslopeforbroadbandimagingoveralongfocaldepth AT huajianyu diffractiveachromatwithfreeformslopeforbroadbandimagingoveralongfocaldepth AT chenlinsen diffractiveachromatwithfreeformslopeforbroadbandimagingoveralongfocaldepth AT qiaowen diffractiveachromatwithfreeformslopeforbroadbandimagingoveralongfocaldepth |