Cargando…

Diffractive Achromat with Freeform Slope for Broadband Imaging over a Long Focal Depth

We propose a method for designing a long-focal-depth diffractive achromat (LFDA). By applying rotational symmetric parameterization, an LFDA with a diameter of 10.89 mm is designed over three wavelengths at six focal planes. The smoothly changed slope designed by the binary variable slope search (BV...

Descripción completa

Detalles Bibliográficos
Autores principales: Yi, Donghui, Zhou, Fengbin, Hua, Jianyu, Chen, Linsen, Qiao, Wen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10383085/
https://www.ncbi.nlm.nih.gov/pubmed/37512712
http://dx.doi.org/10.3390/mi14071401
_version_ 1785080820082409472
author Yi, Donghui
Zhou, Fengbin
Hua, Jianyu
Chen, Linsen
Qiao, Wen
author_facet Yi, Donghui
Zhou, Fengbin
Hua, Jianyu
Chen, Linsen
Qiao, Wen
author_sort Yi, Donghui
collection PubMed
description We propose a method for designing a long-focal-depth diffractive achromat (LFDA). By applying rotational symmetric parameterization, an LFDA with a diameter of 10.89 mm is designed over three wavelengths at six focal planes. The smoothly changed slope designed by the binary variable slope search (BVSS) algorithm greatly reduces the discontinuity in depth, thus it is a fabrication-friendly process for grayscale laser direct writing lithography, involving less fabrication error and cost. The deviation between the designed and fabricated profiles amounts to 9.68%. The LFDA operates at multiple wavelengths (654 nm, 545 nm, and 467 nm) with a DOF of 500 mm~7.65λ × 10(5) (λ = 654 nm). The simulated and measured full-width at half-maximum (FWHM) of the focused beam is close to the diffraction limit. Experimental studies suggest that the LFDA possesses a superior capability to form high-quality chromatic images in a wide range of depths of field. The LFDA opens a new avenue to achieve compact achromatic systems for imaging, sensing, and 3D display.
format Online
Article
Text
id pubmed-10383085
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103830852023-07-30 Diffractive Achromat with Freeform Slope for Broadband Imaging over a Long Focal Depth Yi, Donghui Zhou, Fengbin Hua, Jianyu Chen, Linsen Qiao, Wen Micromachines (Basel) Article We propose a method for designing a long-focal-depth diffractive achromat (LFDA). By applying rotational symmetric parameterization, an LFDA with a diameter of 10.89 mm is designed over three wavelengths at six focal planes. The smoothly changed slope designed by the binary variable slope search (BVSS) algorithm greatly reduces the discontinuity in depth, thus it is a fabrication-friendly process for grayscale laser direct writing lithography, involving less fabrication error and cost. The deviation between the designed and fabricated profiles amounts to 9.68%. The LFDA operates at multiple wavelengths (654 nm, 545 nm, and 467 nm) with a DOF of 500 mm~7.65λ × 10(5) (λ = 654 nm). The simulated and measured full-width at half-maximum (FWHM) of the focused beam is close to the diffraction limit. Experimental studies suggest that the LFDA possesses a superior capability to form high-quality chromatic images in a wide range of depths of field. The LFDA opens a new avenue to achieve compact achromatic systems for imaging, sensing, and 3D display. MDPI 2023-07-09 /pmc/articles/PMC10383085/ /pubmed/37512712 http://dx.doi.org/10.3390/mi14071401 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Yi, Donghui
Zhou, Fengbin
Hua, Jianyu
Chen, Linsen
Qiao, Wen
Diffractive Achromat with Freeform Slope for Broadband Imaging over a Long Focal Depth
title Diffractive Achromat with Freeform Slope for Broadband Imaging over a Long Focal Depth
title_full Diffractive Achromat with Freeform Slope for Broadband Imaging over a Long Focal Depth
title_fullStr Diffractive Achromat with Freeform Slope for Broadband Imaging over a Long Focal Depth
title_full_unstemmed Diffractive Achromat with Freeform Slope for Broadband Imaging over a Long Focal Depth
title_short Diffractive Achromat with Freeform Slope for Broadband Imaging over a Long Focal Depth
title_sort diffractive achromat with freeform slope for broadband imaging over a long focal depth
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10383085/
https://www.ncbi.nlm.nih.gov/pubmed/37512712
http://dx.doi.org/10.3390/mi14071401
work_keys_str_mv AT yidonghui diffractiveachromatwithfreeformslopeforbroadbandimagingoveralongfocaldepth
AT zhoufengbin diffractiveachromatwithfreeformslopeforbroadbandimagingoveralongfocaldepth
AT huajianyu diffractiveachromatwithfreeformslopeforbroadbandimagingoveralongfocaldepth
AT chenlinsen diffractiveachromatwithfreeformslopeforbroadbandimagingoveralongfocaldepth
AT qiaowen diffractiveachromatwithfreeformslopeforbroadbandimagingoveralongfocaldepth