Cargando…

Integrated High-Temporal-Resolution and High-Density Subretinal Prosthesis Using a Correlated Double-Sampling Technique

This paper presents a 1600-pixel integrated neural stimulator with a correlated double-sampling readout (DSR) circuit for a subretinal prosthesis. The retinal stimulation chip inserted beneath the photoreceptor layer comprises an array of an active pixel sensor (APS) and biphasic pulse shaper. The D...

Descripción completa

Detalles Bibliográficos
Autores principales: Kang, Hosung, Kim, Jungyeon, Kim, Jungsuk
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10383336/
https://www.ncbi.nlm.nih.gov/pubmed/37514794
http://dx.doi.org/10.3390/s23146501
_version_ 1785080884619116544
author Kang, Hosung
Kim, Jungyeon
Kim, Jungsuk
author_facet Kang, Hosung
Kim, Jungyeon
Kim, Jungsuk
author_sort Kang, Hosung
collection PubMed
description This paper presents a 1600-pixel integrated neural stimulator with a correlated double-sampling readout (DSR) circuit for a subretinal prosthesis. The retinal stimulation chip inserted beneath the photoreceptor layer comprises an array of an active pixel sensor (APS) and biphasic pulse shaper. The DSR circuit achieves a high signal-to-noise ratio (SNR) of the APS with a short integration time to simultaneously improve the temporal and spatial resolutions of restored vision. This DSR circuit is adopted along with a 5 × 5-pixel tile, which reduces pixel size and improves the SNR by increasing the area occupied by storage capacitors. Moreover, a low-mismatch reference generator enables a low standard deviation between individual pulse shapers. The 1600-pixel retinal chip, fabricated using the 0.18 μm 1P6M CMOS process, occupies a total area of 4.3 mm × 3.3 mm and dissipates an average power of 3.4 mW; this was demonstrated by determining the stimulus current patterns corresponding to the illuminations of an LCD projector. Experimental results show that the proposed high-density stimulation array chip can achieve a high temporal resolution owing to its short integration time.
format Online
Article
Text
id pubmed-10383336
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103833362023-07-30 Integrated High-Temporal-Resolution and High-Density Subretinal Prosthesis Using a Correlated Double-Sampling Technique Kang, Hosung Kim, Jungyeon Kim, Jungsuk Sensors (Basel) Communication This paper presents a 1600-pixel integrated neural stimulator with a correlated double-sampling readout (DSR) circuit for a subretinal prosthesis. The retinal stimulation chip inserted beneath the photoreceptor layer comprises an array of an active pixel sensor (APS) and biphasic pulse shaper. The DSR circuit achieves a high signal-to-noise ratio (SNR) of the APS with a short integration time to simultaneously improve the temporal and spatial resolutions of restored vision. This DSR circuit is adopted along with a 5 × 5-pixel tile, which reduces pixel size and improves the SNR by increasing the area occupied by storage capacitors. Moreover, a low-mismatch reference generator enables a low standard deviation between individual pulse shapers. The 1600-pixel retinal chip, fabricated using the 0.18 μm 1P6M CMOS process, occupies a total area of 4.3 mm × 3.3 mm and dissipates an average power of 3.4 mW; this was demonstrated by determining the stimulus current patterns corresponding to the illuminations of an LCD projector. Experimental results show that the proposed high-density stimulation array chip can achieve a high temporal resolution owing to its short integration time. MDPI 2023-07-18 /pmc/articles/PMC10383336/ /pubmed/37514794 http://dx.doi.org/10.3390/s23146501 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Kang, Hosung
Kim, Jungyeon
Kim, Jungsuk
Integrated High-Temporal-Resolution and High-Density Subretinal Prosthesis Using a Correlated Double-Sampling Technique
title Integrated High-Temporal-Resolution and High-Density Subretinal Prosthesis Using a Correlated Double-Sampling Technique
title_full Integrated High-Temporal-Resolution and High-Density Subretinal Prosthesis Using a Correlated Double-Sampling Technique
title_fullStr Integrated High-Temporal-Resolution and High-Density Subretinal Prosthesis Using a Correlated Double-Sampling Technique
title_full_unstemmed Integrated High-Temporal-Resolution and High-Density Subretinal Prosthesis Using a Correlated Double-Sampling Technique
title_short Integrated High-Temporal-Resolution and High-Density Subretinal Prosthesis Using a Correlated Double-Sampling Technique
title_sort integrated high-temporal-resolution and high-density subretinal prosthesis using a correlated double-sampling technique
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10383336/
https://www.ncbi.nlm.nih.gov/pubmed/37514794
http://dx.doi.org/10.3390/s23146501
work_keys_str_mv AT kanghosung integratedhightemporalresolutionandhighdensitysubretinalprosthesisusingacorrelateddoublesamplingtechnique
AT kimjungyeon integratedhightemporalresolutionandhighdensitysubretinalprosthesisusingacorrelateddoublesamplingtechnique
AT kimjungsuk integratedhightemporalresolutionandhighdensitysubretinalprosthesisusingacorrelateddoublesamplingtechnique