Integrated High-Temporal-Resolution and High-Density Subretinal Prosthesis Using a Correlated Double-Sampling Technique
This paper presents a 1600-pixel integrated neural stimulator with a correlated double-sampling readout (DSR) circuit for a subretinal prosthesis. The retinal stimulation chip inserted beneath the photoreceptor layer comprises an array of an active pixel sensor (APS) and biphasic pulse shaper. The D...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10383336/ https://www.ncbi.nlm.nih.gov/pubmed/37514794 http://dx.doi.org/10.3390/s23146501 |
_version_ | 1785080884619116544 |
---|---|
author | Kang, Hosung Kim, Jungyeon Kim, Jungsuk |
author_facet | Kang, Hosung Kim, Jungyeon Kim, Jungsuk |
author_sort | Kang, Hosung |
collection | PubMed |
description | This paper presents a 1600-pixel integrated neural stimulator with a correlated double-sampling readout (DSR) circuit for a subretinal prosthesis. The retinal stimulation chip inserted beneath the photoreceptor layer comprises an array of an active pixel sensor (APS) and biphasic pulse shaper. The DSR circuit achieves a high signal-to-noise ratio (SNR) of the APS with a short integration time to simultaneously improve the temporal and spatial resolutions of restored vision. This DSR circuit is adopted along with a 5 × 5-pixel tile, which reduces pixel size and improves the SNR by increasing the area occupied by storage capacitors. Moreover, a low-mismatch reference generator enables a low standard deviation between individual pulse shapers. The 1600-pixel retinal chip, fabricated using the 0.18 μm 1P6M CMOS process, occupies a total area of 4.3 mm × 3.3 mm and dissipates an average power of 3.4 mW; this was demonstrated by determining the stimulus current patterns corresponding to the illuminations of an LCD projector. Experimental results show that the proposed high-density stimulation array chip can achieve a high temporal resolution owing to its short integration time. |
format | Online Article Text |
id | pubmed-10383336 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-103833362023-07-30 Integrated High-Temporal-Resolution and High-Density Subretinal Prosthesis Using a Correlated Double-Sampling Technique Kang, Hosung Kim, Jungyeon Kim, Jungsuk Sensors (Basel) Communication This paper presents a 1600-pixel integrated neural stimulator with a correlated double-sampling readout (DSR) circuit for a subretinal prosthesis. The retinal stimulation chip inserted beneath the photoreceptor layer comprises an array of an active pixel sensor (APS) and biphasic pulse shaper. The DSR circuit achieves a high signal-to-noise ratio (SNR) of the APS with a short integration time to simultaneously improve the temporal and spatial resolutions of restored vision. This DSR circuit is adopted along with a 5 × 5-pixel tile, which reduces pixel size and improves the SNR by increasing the area occupied by storage capacitors. Moreover, a low-mismatch reference generator enables a low standard deviation between individual pulse shapers. The 1600-pixel retinal chip, fabricated using the 0.18 μm 1P6M CMOS process, occupies a total area of 4.3 mm × 3.3 mm and dissipates an average power of 3.4 mW; this was demonstrated by determining the stimulus current patterns corresponding to the illuminations of an LCD projector. Experimental results show that the proposed high-density stimulation array chip can achieve a high temporal resolution owing to its short integration time. MDPI 2023-07-18 /pmc/articles/PMC10383336/ /pubmed/37514794 http://dx.doi.org/10.3390/s23146501 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Communication Kang, Hosung Kim, Jungyeon Kim, Jungsuk Integrated High-Temporal-Resolution and High-Density Subretinal Prosthesis Using a Correlated Double-Sampling Technique |
title | Integrated High-Temporal-Resolution and High-Density Subretinal Prosthesis Using a Correlated Double-Sampling Technique |
title_full | Integrated High-Temporal-Resolution and High-Density Subretinal Prosthesis Using a Correlated Double-Sampling Technique |
title_fullStr | Integrated High-Temporal-Resolution and High-Density Subretinal Prosthesis Using a Correlated Double-Sampling Technique |
title_full_unstemmed | Integrated High-Temporal-Resolution and High-Density Subretinal Prosthesis Using a Correlated Double-Sampling Technique |
title_short | Integrated High-Temporal-Resolution and High-Density Subretinal Prosthesis Using a Correlated Double-Sampling Technique |
title_sort | integrated high-temporal-resolution and high-density subretinal prosthesis using a correlated double-sampling technique |
topic | Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10383336/ https://www.ncbi.nlm.nih.gov/pubmed/37514794 http://dx.doi.org/10.3390/s23146501 |
work_keys_str_mv | AT kanghosung integratedhightemporalresolutionandhighdensitysubretinalprosthesisusingacorrelateddoublesamplingtechnique AT kimjungyeon integratedhightemporalresolutionandhighdensitysubretinalprosthesisusingacorrelateddoublesamplingtechnique AT kimjungsuk integratedhightemporalresolutionandhighdensitysubretinalprosthesisusingacorrelateddoublesamplingtechnique |