Cargando…
Design of Photonic Crystal Biosensors for Cancer Cell Detection
A photonic crystal biosensor is a compact device fabricated from photonic crystal materials, which enables the detection and monitoring of the presence and concentration changes of biological molecules or chemical substances. In this paper, we propose a biosensor for cancer cell detection based on a...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10383766/ https://www.ncbi.nlm.nih.gov/pubmed/37512789 http://dx.doi.org/10.3390/mi14071478 |
_version_ | 1785080991756320768 |
---|---|
author | Yang, Yang Xiang, Yang Qi, Xubin |
author_facet | Yang, Yang Xiang, Yang Qi, Xubin |
author_sort | Yang, Yang |
collection | PubMed |
description | A photonic crystal biosensor is a compact device fabricated from photonic crystal materials, which enables the detection and monitoring of the presence and concentration changes of biological molecules or chemical substances. In this paper, we propose a biosensor for cancer cell detection based on a silicon photonic crystal with a hexagonal resonant cavity introduced in a triangular lattice array. One of the bandgap ranges of this structure is [Formula: see text]. When the incident light wavelength is within the range of [Formula: see text] , the transmission coefficient of this structure at the resonant wavelength of 1469.58 nm is found to reach 99.62% through the finite difference time domain method, with a quality factor of 980. Subsequently, a biosensor is designed from this structure, with its sensing mechanism relying on the change in refractive index leading to a shift in the resonant wavelength. The target sample can be identified by observing the shift in the resonant wavelength. As cancer cells and normal cells possess different refractive indices, this biosensor can be used for their detection. The maximum sensitivity of the sensor is 915.75 nm/RIU and the minimum detection limit is 0.000236 RIU. |
format | Online Article Text |
id | pubmed-10383766 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-103837662023-07-30 Design of Photonic Crystal Biosensors for Cancer Cell Detection Yang, Yang Xiang, Yang Qi, Xubin Micromachines (Basel) Article A photonic crystal biosensor is a compact device fabricated from photonic crystal materials, which enables the detection and monitoring of the presence and concentration changes of biological molecules or chemical substances. In this paper, we propose a biosensor for cancer cell detection based on a silicon photonic crystal with a hexagonal resonant cavity introduced in a triangular lattice array. One of the bandgap ranges of this structure is [Formula: see text]. When the incident light wavelength is within the range of [Formula: see text] , the transmission coefficient of this structure at the resonant wavelength of 1469.58 nm is found to reach 99.62% through the finite difference time domain method, with a quality factor of 980. Subsequently, a biosensor is designed from this structure, with its sensing mechanism relying on the change in refractive index leading to a shift in the resonant wavelength. The target sample can be identified by observing the shift in the resonant wavelength. As cancer cells and normal cells possess different refractive indices, this biosensor can be used for their detection. The maximum sensitivity of the sensor is 915.75 nm/RIU and the minimum detection limit is 0.000236 RIU. MDPI 2023-07-23 /pmc/articles/PMC10383766/ /pubmed/37512789 http://dx.doi.org/10.3390/mi14071478 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Yang, Yang Xiang, Yang Qi, Xubin Design of Photonic Crystal Biosensors for Cancer Cell Detection |
title | Design of Photonic Crystal Biosensors for Cancer Cell Detection |
title_full | Design of Photonic Crystal Biosensors for Cancer Cell Detection |
title_fullStr | Design of Photonic Crystal Biosensors for Cancer Cell Detection |
title_full_unstemmed | Design of Photonic Crystal Biosensors for Cancer Cell Detection |
title_short | Design of Photonic Crystal Biosensors for Cancer Cell Detection |
title_sort | design of photonic crystal biosensors for cancer cell detection |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10383766/ https://www.ncbi.nlm.nih.gov/pubmed/37512789 http://dx.doi.org/10.3390/mi14071478 |
work_keys_str_mv | AT yangyang designofphotoniccrystalbiosensorsforcancercelldetection AT xiangyang designofphotoniccrystalbiosensorsforcancercelldetection AT qixubin designofphotoniccrystalbiosensorsforcancercelldetection |