Few-Shot Learning-Based Light-Weight WDCNN Model for Bearing Fault Diagnosis in Siamese Network
In this study, bearing fault diagnosis is performed with a small amount of data through few-shot learning. Recently, a fault diagnosis method based on deep learning has achieved promising results. Most studies required numerous training samples for fault diagnosis. However, at manufacturing sites, i...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10383807/ https://www.ncbi.nlm.nih.gov/pubmed/37514880 http://dx.doi.org/10.3390/s23146587 |
_version_ | 1785081001719889920 |
---|---|
author | Lee, Daehwan Jeong, Jongpil |
author_facet | Lee, Daehwan Jeong, Jongpil |
author_sort | Lee, Daehwan |
collection | PubMed |
description | In this study, bearing fault diagnosis is performed with a small amount of data through few-shot learning. Recently, a fault diagnosis method based on deep learning has achieved promising results. Most studies required numerous training samples for fault diagnosis. However, at manufacturing sites, it is impossible to have enough training samples to represent all fault types under all operating conditions. In addition, most studies consider only accuracy, and models are complex and computationally expensive. Research that only considers accuracy is inefficient since manufacturing sites change rapidly. Therefore, in this study, we propose a few-shot learning model that can effectively learn with small data. In addition, a Depthwise Separable Convolution layer that can effectively reduce parameters is used together. In order to find an efficient model, the optimal hyperparameters were found by adjusting the number of blocks and hyperparameters, and by using a Depthwise Separable Convolution layer for the optimal hyperparameters, it showed higher accuracy and fewer parameters than the existing model. |
format | Online Article Text |
id | pubmed-10383807 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-103838072023-07-30 Few-Shot Learning-Based Light-Weight WDCNN Model for Bearing Fault Diagnosis in Siamese Network Lee, Daehwan Jeong, Jongpil Sensors (Basel) Article In this study, bearing fault diagnosis is performed with a small amount of data through few-shot learning. Recently, a fault diagnosis method based on deep learning has achieved promising results. Most studies required numerous training samples for fault diagnosis. However, at manufacturing sites, it is impossible to have enough training samples to represent all fault types under all operating conditions. In addition, most studies consider only accuracy, and models are complex and computationally expensive. Research that only considers accuracy is inefficient since manufacturing sites change rapidly. Therefore, in this study, we propose a few-shot learning model that can effectively learn with small data. In addition, a Depthwise Separable Convolution layer that can effectively reduce parameters is used together. In order to find an efficient model, the optimal hyperparameters were found by adjusting the number of blocks and hyperparameters, and by using a Depthwise Separable Convolution layer for the optimal hyperparameters, it showed higher accuracy and fewer parameters than the existing model. MDPI 2023-07-21 /pmc/articles/PMC10383807/ /pubmed/37514880 http://dx.doi.org/10.3390/s23146587 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lee, Daehwan Jeong, Jongpil Few-Shot Learning-Based Light-Weight WDCNN Model for Bearing Fault Diagnosis in Siamese Network |
title | Few-Shot Learning-Based Light-Weight WDCNN Model for Bearing Fault Diagnosis in Siamese Network |
title_full | Few-Shot Learning-Based Light-Weight WDCNN Model for Bearing Fault Diagnosis in Siamese Network |
title_fullStr | Few-Shot Learning-Based Light-Weight WDCNN Model for Bearing Fault Diagnosis in Siamese Network |
title_full_unstemmed | Few-Shot Learning-Based Light-Weight WDCNN Model for Bearing Fault Diagnosis in Siamese Network |
title_short | Few-Shot Learning-Based Light-Weight WDCNN Model for Bearing Fault Diagnosis in Siamese Network |
title_sort | few-shot learning-based light-weight wdcnn model for bearing fault diagnosis in siamese network |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10383807/ https://www.ncbi.nlm.nih.gov/pubmed/37514880 http://dx.doi.org/10.3390/s23146587 |
work_keys_str_mv | AT leedaehwan fewshotlearningbasedlightweightwdcnnmodelforbearingfaultdiagnosisinsiamesenetwork AT jeongjongpil fewshotlearningbasedlightweightwdcnnmodelforbearingfaultdiagnosisinsiamesenetwork |