Novel Multi-Parametric Sensor System for Comprehensive Multi-Wavelength Photoplethysmography Characterization

Photoplethysmography (PPG) is widely used to assess cardiovascular health. However, its usage and standardization are limited by the impact of variable contact force and temperature, which influence the accuracy and reliability of the measurements. Although some studies have evaluated the impact of...

Descripción completa

Detalles Bibliográficos
Autores principales: Lambert Cause, Joan, Solé Morillo, Ángel, da Silva, Bruno, García-Naranjo, Juan C., Stiens, Johan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10384342/
https://www.ncbi.nlm.nih.gov/pubmed/37514922
http://dx.doi.org/10.3390/s23146628
_version_ 1785081133930643456
author Lambert Cause, Joan
Solé Morillo, Ángel
da Silva, Bruno
García-Naranjo, Juan C.
Stiens, Johan
author_facet Lambert Cause, Joan
Solé Morillo, Ángel
da Silva, Bruno
García-Naranjo, Juan C.
Stiens, Johan
author_sort Lambert Cause, Joan
collection PubMed
description Photoplethysmography (PPG) is widely used to assess cardiovascular health. However, its usage and standardization are limited by the impact of variable contact force and temperature, which influence the accuracy and reliability of the measurements. Although some studies have evaluated the impact of these phenomena on signal amplitude, there is still a lack of knowledge about how these perturbations can distort the signal morphology, especially for multi-wavelength PPG (MW-PPG) measurements. This work presents a modular multi-parametric sensor system that integrates continuous and real-time acquisition of MW-PPG, contact force, and temperature signals. The implemented design solution allows for a comprehensive characterization of the effects of the variations in these phenomena on the contour of the MW-PPG signal. Furthermore, a dynamic DC cancellation circuitry was implemented to improve measurement resolution and obtain high-quality raw multi-parametric data. The accuracy of the MW-PPG signal acquisition was assessed using a synthesized reference PPG optical signal. The performance of the contact force and temperature sensors was evaluated as well. To determine the overall quality of the multi-parametric measurement, an in vivo measurement on the index finger of a volunteer was performed. The results indicate a high precision and accuracy in the measurements, wherein the capacity of the system to obtain high-resolution and low-distortion MW-PPG signals is highlighted. These findings will contribute to developing new signal-processing approaches, advancing the accuracy and robustness of PPG-based systems, and bridging existing gaps in the literature.
format Online
Article
Text
id pubmed-10384342
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103843422023-07-30 Novel Multi-Parametric Sensor System for Comprehensive Multi-Wavelength Photoplethysmography Characterization Lambert Cause, Joan Solé Morillo, Ángel da Silva, Bruno García-Naranjo, Juan C. Stiens, Johan Sensors (Basel) Article Photoplethysmography (PPG) is widely used to assess cardiovascular health. However, its usage and standardization are limited by the impact of variable contact force and temperature, which influence the accuracy and reliability of the measurements. Although some studies have evaluated the impact of these phenomena on signal amplitude, there is still a lack of knowledge about how these perturbations can distort the signal morphology, especially for multi-wavelength PPG (MW-PPG) measurements. This work presents a modular multi-parametric sensor system that integrates continuous and real-time acquisition of MW-PPG, contact force, and temperature signals. The implemented design solution allows for a comprehensive characterization of the effects of the variations in these phenomena on the contour of the MW-PPG signal. Furthermore, a dynamic DC cancellation circuitry was implemented to improve measurement resolution and obtain high-quality raw multi-parametric data. The accuracy of the MW-PPG signal acquisition was assessed using a synthesized reference PPG optical signal. The performance of the contact force and temperature sensors was evaluated as well. To determine the overall quality of the multi-parametric measurement, an in vivo measurement on the index finger of a volunteer was performed. The results indicate a high precision and accuracy in the measurements, wherein the capacity of the system to obtain high-resolution and low-distortion MW-PPG signals is highlighted. These findings will contribute to developing new signal-processing approaches, advancing the accuracy and robustness of PPG-based systems, and bridging existing gaps in the literature. MDPI 2023-07-24 /pmc/articles/PMC10384342/ /pubmed/37514922 http://dx.doi.org/10.3390/s23146628 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lambert Cause, Joan
Solé Morillo, Ángel
da Silva, Bruno
García-Naranjo, Juan C.
Stiens, Johan
Novel Multi-Parametric Sensor System for Comprehensive Multi-Wavelength Photoplethysmography Characterization
title Novel Multi-Parametric Sensor System for Comprehensive Multi-Wavelength Photoplethysmography Characterization
title_full Novel Multi-Parametric Sensor System for Comprehensive Multi-Wavelength Photoplethysmography Characterization
title_fullStr Novel Multi-Parametric Sensor System for Comprehensive Multi-Wavelength Photoplethysmography Characterization
title_full_unstemmed Novel Multi-Parametric Sensor System for Comprehensive Multi-Wavelength Photoplethysmography Characterization
title_short Novel Multi-Parametric Sensor System for Comprehensive Multi-Wavelength Photoplethysmography Characterization
title_sort novel multi-parametric sensor system for comprehensive multi-wavelength photoplethysmography characterization
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10384342/
https://www.ncbi.nlm.nih.gov/pubmed/37514922
http://dx.doi.org/10.3390/s23146628
work_keys_str_mv AT lambertcausejoan novelmultiparametricsensorsystemforcomprehensivemultiwavelengthphotoplethysmographycharacterization
AT solemorilloangel novelmultiparametricsensorsystemforcomprehensivemultiwavelengthphotoplethysmographycharacterization
AT dasilvabruno novelmultiparametricsensorsystemforcomprehensivemultiwavelengthphotoplethysmographycharacterization
AT garcianaranjojuanc novelmultiparametricsensorsystemforcomprehensivemultiwavelengthphotoplethysmographycharacterization
AT stiensjohan novelmultiparametricsensorsystemforcomprehensivemultiwavelengthphotoplethysmographycharacterization