A Sage–Husa Prediction Algorithm-Based Approach for Correcting the Hall Sensor Position in DC Brushless Motors

Accurate knowledge of the rotor position is essential for the control of brushless DC motors (BLDCM). Any deviation in this identification can cause fluctuations in motor current and torque, increase noise, and lead to reduced motor efficiency. This paper focused on a BLDCM equipped with a three-pha...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Lu, Cheng, Yong, Yin, Wei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10384790/
https://www.ncbi.nlm.nih.gov/pubmed/37514898
http://dx.doi.org/10.3390/s23146604
_version_ 1785081243809873920
author Wang, Lu
Cheng, Yong
Yin, Wei
author_facet Wang, Lu
Cheng, Yong
Yin, Wei
author_sort Wang, Lu
collection PubMed
description Accurate knowledge of the rotor position is essential for the control of brushless DC motors (BLDCM). Any deviation in this identification can cause fluctuations in motor current and torque, increase noise, and lead to reduced motor efficiency. This paper focused on a BLDCM equipped with a three-phase binary Hall sensor. Based on the principle of minimum deviation, this paper estimated the relative installation offset between the Hall sensors. It also provided a clear method for ideal phase commutation position recognition and eliminated the Hall sensor installation position deviation. The proposed pre-calibration method identified and eliminated the offset of the permanent magnet poles, the delay time caused by the Hall signal conditioning circuit, and the offset of the sensor signal identification due to armature response under different loads. Based on the pre-calibration results, a correction strategy for correcting the rotor position information of BLDCMs was proposed. This paper presented a self-adaptive position information prediction algorithm based on the Sage–Husa method. This filters out rotor position information deviations that are not eliminated in pre-calibration. Experimental results on a hydrogen circulation pump motor showed that, after the pre-calibration method was adopted, the Mean Square Error (MSE) of motor speed fluctuations decreased by 92.0%, motor vibration was significantly reduced, average phase current decreased by 62.8%, and the efficiency of the hydrogen circulation pump system was significantly improved. Compared to the traditional KF prediction algorithm, the Sage–Husa adaptive position information prediction algorithm reduced the speed fluctuation during the uniform speed operation stage and speed adjustment stage, the speed curve overshoot, and the commutation time deviation throughout the process by 44.8%, 56.0%, 54.9%, and 14.7%, respectively. This indicates a higher disturbance rejection ability and a more accurate and stable prediction of the commutation moment.
format Online
Article
Text
id pubmed-10384790
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103847902023-07-30 A Sage–Husa Prediction Algorithm-Based Approach for Correcting the Hall Sensor Position in DC Brushless Motors Wang, Lu Cheng, Yong Yin, Wei Sensors (Basel) Article Accurate knowledge of the rotor position is essential for the control of brushless DC motors (BLDCM). Any deviation in this identification can cause fluctuations in motor current and torque, increase noise, and lead to reduced motor efficiency. This paper focused on a BLDCM equipped with a three-phase binary Hall sensor. Based on the principle of minimum deviation, this paper estimated the relative installation offset between the Hall sensors. It also provided a clear method for ideal phase commutation position recognition and eliminated the Hall sensor installation position deviation. The proposed pre-calibration method identified and eliminated the offset of the permanent magnet poles, the delay time caused by the Hall signal conditioning circuit, and the offset of the sensor signal identification due to armature response under different loads. Based on the pre-calibration results, a correction strategy for correcting the rotor position information of BLDCMs was proposed. This paper presented a self-adaptive position information prediction algorithm based on the Sage–Husa method. This filters out rotor position information deviations that are not eliminated in pre-calibration. Experimental results on a hydrogen circulation pump motor showed that, after the pre-calibration method was adopted, the Mean Square Error (MSE) of motor speed fluctuations decreased by 92.0%, motor vibration was significantly reduced, average phase current decreased by 62.8%, and the efficiency of the hydrogen circulation pump system was significantly improved. Compared to the traditional KF prediction algorithm, the Sage–Husa adaptive position information prediction algorithm reduced the speed fluctuation during the uniform speed operation stage and speed adjustment stage, the speed curve overshoot, and the commutation time deviation throughout the process by 44.8%, 56.0%, 54.9%, and 14.7%, respectively. This indicates a higher disturbance rejection ability and a more accurate and stable prediction of the commutation moment. MDPI 2023-07-22 /pmc/articles/PMC10384790/ /pubmed/37514898 http://dx.doi.org/10.3390/s23146604 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wang, Lu
Cheng, Yong
Yin, Wei
A Sage–Husa Prediction Algorithm-Based Approach for Correcting the Hall Sensor Position in DC Brushless Motors
title A Sage–Husa Prediction Algorithm-Based Approach for Correcting the Hall Sensor Position in DC Brushless Motors
title_full A Sage–Husa Prediction Algorithm-Based Approach for Correcting the Hall Sensor Position in DC Brushless Motors
title_fullStr A Sage–Husa Prediction Algorithm-Based Approach for Correcting the Hall Sensor Position in DC Brushless Motors
title_full_unstemmed A Sage–Husa Prediction Algorithm-Based Approach for Correcting the Hall Sensor Position in DC Brushless Motors
title_short A Sage–Husa Prediction Algorithm-Based Approach for Correcting the Hall Sensor Position in DC Brushless Motors
title_sort sage–husa prediction algorithm-based approach for correcting the hall sensor position in dc brushless motors
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10384790/
https://www.ncbi.nlm.nih.gov/pubmed/37514898
http://dx.doi.org/10.3390/s23146604
work_keys_str_mv AT wanglu asagehusapredictionalgorithmbasedapproachforcorrectingthehallsensorpositionindcbrushlessmotors
AT chengyong asagehusapredictionalgorithmbasedapproachforcorrectingthehallsensorpositionindcbrushlessmotors
AT yinwei asagehusapredictionalgorithmbasedapproachforcorrectingthehallsensorpositionindcbrushlessmotors
AT wanglu sagehusapredictionalgorithmbasedapproachforcorrectingthehallsensorpositionindcbrushlessmotors
AT chengyong sagehusapredictionalgorithmbasedapproachforcorrectingthehallsensorpositionindcbrushlessmotors
AT yinwei sagehusapredictionalgorithmbasedapproachforcorrectingthehallsensorpositionindcbrushlessmotors