Cargando…
Single-Center Experience of Control of Ventilator-Circuit-Transmitted Burkholderia cepacia Outbreak in an Intensive Care Unit
Burkholderia cepacia is an emerging nosocomial pathogen frequently associated with outbreaks, but the exact transmission route of this pathogen can at times be elusive in spite of extensive environmental investigative cultures. Active surveillance for sputum cultures was performed for all patients f...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10384831/ https://www.ncbi.nlm.nih.gov/pubmed/37505631 http://dx.doi.org/10.3390/tropicalmed8070335 |
Sumario: | Burkholderia cepacia is an emerging nosocomial pathogen frequently associated with outbreaks, but the exact transmission route of this pathogen can at times be elusive in spite of extensive environmental investigative cultures. Active surveillance for sputum cultures was performed for all patients from September 2008 to September 2009 in an intensive care unit (ICU) with B. cepacia outbreak. With evidence of persistent positive conversion of sputum cultures (colonization) and infections among patients, discontinuing re-usable ventilator circuits was introduced. A total of 689 patients were admitted to this unit for a mean duration of 8.7 ± 7.5 days. There were 489 patients (71.0%) with a stay for one to ten days; 161 (23.4%) patients for 11 to 20 days; and 39 (5.7%) with over 20 days. In the first group, 13.5% of patients had cultures converting from negative to positive, in contrast to 66.7% in the last group (p < 0.01). With intervention of using disposable ventilator circuits since June 2009, the incidence of isolated B. cepacia decreased gradually. The estimated 30-day isolation-free probabilities of the groups before, during, one month (August 2009) after, and two months (September 2009) after this intervention were 38.5%, 47.3%, 66.5%, and 96.0%, respectively (p < 0.01). Furthermore, the effect of discontinuing reusable ventilator circuit persisted in the following 6 years; both total isolates of B. cepacia and the infection caused by it were much lower compared to the outbreak period. In summary, this six-year outbreak in a medical ICU persisted until reusable ventilator circuits were discontinued in 2009. The effect of disposable circuits on the decreased incidence of B. cepacia infection maintained in the following years. |
---|