Cargando…
Simulation and Optimization of the Auxiliary Cathode for Inter-Electrode Discharge Electric Field in Microarc Oxidation
Currently, research on the edge effect issue in the micro-arc oxidation process primarily focuses on investigating process conditions and enhancing additives. However, some scholars have utilized finite element analysis software to simulate the edge effect during the simulation process, overlooking...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10385251/ https://www.ncbi.nlm.nih.gov/pubmed/37512337 http://dx.doi.org/10.3390/ma16145065 |
_version_ | 1785081359783428096 |
---|---|
author | Lv, Pengxiang Zhang, Xiaozhou Chen, Lei Wang, Shixuan Wang, Zhen He, Rongguo Guan, Le |
author_facet | Lv, Pengxiang Zhang, Xiaozhou Chen, Lei Wang, Shixuan Wang, Zhen He, Rongguo Guan, Le |
author_sort | Lv, Pengxiang |
collection | PubMed |
description | Currently, research on the edge effect issue in the micro-arc oxidation process primarily focuses on investigating process conditions and enhancing additives. However, some scholars have utilized finite element analysis software to simulate the edge effect during the simulation process, overlooking the investigation of the morphology of the auxiliary cathode. This study analyzes the growth characteristics of the oxide film on aluminum alloy 2A12 during micro-arc oxidation. Additionally, the inter-electrode discharge electric field is simulated using the finite element analysis method. The auxiliary cathode is optimized to mitigate the influence of the edge effect on the film layer. The findings indicate that employing a cylindrical shape as the auxiliary cathode instead of a rectangular groove leads to an increased thickness of the micro-arc oxidation film. However, it also results in an augmented length of the film layer affected by the edge effect at both ends of the workpiece. Decreasing the distance between the auxiliary cathode and the workpiece surface leads to a higher thickness of the obtained micro-arc oxidation film. Decreasing the length of the auxiliary cathode results in a reduction in both the thickness of the film layer on the workpiece surface and the area affected by the edge effect. Increasing the eccentric cone ratio of the auxiliary cathode enhances the uniformity of the micro-arc oxidation film layer. In this study, we present a novel auxiliary cathode model that incorporates a smaller cylindrical shell at the center and eccentric cone shells on each side. This model has the potential to enhance the optimization rate of the micro-arc oxidation film layer on cylindrical workpieces by 17.77%. |
format | Online Article Text |
id | pubmed-10385251 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-103852512023-07-30 Simulation and Optimization of the Auxiliary Cathode for Inter-Electrode Discharge Electric Field in Microarc Oxidation Lv, Pengxiang Zhang, Xiaozhou Chen, Lei Wang, Shixuan Wang, Zhen He, Rongguo Guan, Le Materials (Basel) Article Currently, research on the edge effect issue in the micro-arc oxidation process primarily focuses on investigating process conditions and enhancing additives. However, some scholars have utilized finite element analysis software to simulate the edge effect during the simulation process, overlooking the investigation of the morphology of the auxiliary cathode. This study analyzes the growth characteristics of the oxide film on aluminum alloy 2A12 during micro-arc oxidation. Additionally, the inter-electrode discharge electric field is simulated using the finite element analysis method. The auxiliary cathode is optimized to mitigate the influence of the edge effect on the film layer. The findings indicate that employing a cylindrical shape as the auxiliary cathode instead of a rectangular groove leads to an increased thickness of the micro-arc oxidation film. However, it also results in an augmented length of the film layer affected by the edge effect at both ends of the workpiece. Decreasing the distance between the auxiliary cathode and the workpiece surface leads to a higher thickness of the obtained micro-arc oxidation film. Decreasing the length of the auxiliary cathode results in a reduction in both the thickness of the film layer on the workpiece surface and the area affected by the edge effect. Increasing the eccentric cone ratio of the auxiliary cathode enhances the uniformity of the micro-arc oxidation film layer. In this study, we present a novel auxiliary cathode model that incorporates a smaller cylindrical shell at the center and eccentric cone shells on each side. This model has the potential to enhance the optimization rate of the micro-arc oxidation film layer on cylindrical workpieces by 17.77%. MDPI 2023-07-18 /pmc/articles/PMC10385251/ /pubmed/37512337 http://dx.doi.org/10.3390/ma16145065 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lv, Pengxiang Zhang, Xiaozhou Chen, Lei Wang, Shixuan Wang, Zhen He, Rongguo Guan, Le Simulation and Optimization of the Auxiliary Cathode for Inter-Electrode Discharge Electric Field in Microarc Oxidation |
title | Simulation and Optimization of the Auxiliary Cathode for Inter-Electrode Discharge Electric Field in Microarc Oxidation |
title_full | Simulation and Optimization of the Auxiliary Cathode for Inter-Electrode Discharge Electric Field in Microarc Oxidation |
title_fullStr | Simulation and Optimization of the Auxiliary Cathode for Inter-Electrode Discharge Electric Field in Microarc Oxidation |
title_full_unstemmed | Simulation and Optimization of the Auxiliary Cathode for Inter-Electrode Discharge Electric Field in Microarc Oxidation |
title_short | Simulation and Optimization of the Auxiliary Cathode for Inter-Electrode Discharge Electric Field in Microarc Oxidation |
title_sort | simulation and optimization of the auxiliary cathode for inter-electrode discharge electric field in microarc oxidation |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10385251/ https://www.ncbi.nlm.nih.gov/pubmed/37512337 http://dx.doi.org/10.3390/ma16145065 |
work_keys_str_mv | AT lvpengxiang simulationandoptimizationoftheauxiliarycathodeforinterelectrodedischargeelectricfieldinmicroarcoxidation AT zhangxiaozhou simulationandoptimizationoftheauxiliarycathodeforinterelectrodedischargeelectricfieldinmicroarcoxidation AT chenlei simulationandoptimizationoftheauxiliarycathodeforinterelectrodedischargeelectricfieldinmicroarcoxidation AT wangshixuan simulationandoptimizationoftheauxiliarycathodeforinterelectrodedischargeelectricfieldinmicroarcoxidation AT wangzhen simulationandoptimizationoftheauxiliarycathodeforinterelectrodedischargeelectricfieldinmicroarcoxidation AT herongguo simulationandoptimizationoftheauxiliarycathodeforinterelectrodedischargeelectricfieldinmicroarcoxidation AT guanle simulationandoptimizationoftheauxiliarycathodeforinterelectrodedischargeelectricfieldinmicroarcoxidation |