Cargando…

Clinical Use of Continuous Glucose Monitoring in Critically Ill Pediatric Patients with Diabetic Ketoacidosis

BACKGROUND: The use of continuous glucose monitoring (CGM) in pediatric patients with diabetic ketoacidosis (DKA) remains investigational, and data on its accuracy in pediatric intensive care units (PICU) are limited. This study evaluated the accuracy of three CGM devices in pediatric patients with...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Esther, Kim, Minsun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Mary Ann Liebert, Inc., publishers 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10387156/
https://www.ncbi.nlm.nih.gov/pubmed/37155338
http://dx.doi.org/10.1089/dia.2023.0012
_version_ 1785081822227464192
author Park, Esther
Kim, Minsun
author_facet Park, Esther
Kim, Minsun
author_sort Park, Esther
collection PubMed
description BACKGROUND: The use of continuous glucose monitoring (CGM) in pediatric patients with diabetic ketoacidosis (DKA) remains investigational, and data on its accuracy in pediatric intensive care units (PICU) are limited. This study evaluated the accuracy of three CGM devices in pediatric patients with DKA in the PICU. METHODS: We compared 399 matched pairs of CGM and point-of-care capillary glucose (POC) values and grouped patients based on whether they changed their CGM sensor during their PICU stay. RESULTS: Eighteen patients with a mean age of 10.98 ± 4.20 years were included, with three patients in the sensor change group. The overall mean absolute relative difference (MARD) was 13.02%. The Medtronic Guardian Sensor 3 (n = 331), Dexcom G6 (n = 41), and Abbott FreeStyle Libre 1 (n = 27) showed MARD values of 13.40%, 11.12%, and 11.33%, respectively. The surveillance error grid (SEG), Bland–Altman plot, and Pearson's correlation coefficient demonstrated satisfactory clinical accuracy of the CGM devices (SEG zones A and B, 98.5%; mean difference, 15.5 mg/dL; Pearson's correlation coefficient [r(2)], 0.76, P < 0.0001). MARD was significantly lower in subjects who did not experience a sensor change (11.74% vs. 17.31%, P = 0.048). Also, a statistically significant negative correlation was found between serum bicarbonate levels and POC–CGM values (r = −0.34, P < 0.001). CONCLUSIONS: The severity of DKA has a major effect on reducing the accuracy of the CGM, especially during the first several days in the intensive care unit. The reduced accuracy appears to be related to acidosis, as reflected in the serum bicarbonate levels.
format Online
Article
Text
id pubmed-10387156
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Mary Ann Liebert, Inc., publishers
record_format MEDLINE/PubMed
spelling pubmed-103871562023-07-31 Clinical Use of Continuous Glucose Monitoring in Critically Ill Pediatric Patients with Diabetic Ketoacidosis Park, Esther Kim, Minsun Diabetes Technol Ther Original Articles BACKGROUND: The use of continuous glucose monitoring (CGM) in pediatric patients with diabetic ketoacidosis (DKA) remains investigational, and data on its accuracy in pediatric intensive care units (PICU) are limited. This study evaluated the accuracy of three CGM devices in pediatric patients with DKA in the PICU. METHODS: We compared 399 matched pairs of CGM and point-of-care capillary glucose (POC) values and grouped patients based on whether they changed their CGM sensor during their PICU stay. RESULTS: Eighteen patients with a mean age of 10.98 ± 4.20 years were included, with three patients in the sensor change group. The overall mean absolute relative difference (MARD) was 13.02%. The Medtronic Guardian Sensor 3 (n = 331), Dexcom G6 (n = 41), and Abbott FreeStyle Libre 1 (n = 27) showed MARD values of 13.40%, 11.12%, and 11.33%, respectively. The surveillance error grid (SEG), Bland–Altman plot, and Pearson's correlation coefficient demonstrated satisfactory clinical accuracy of the CGM devices (SEG zones A and B, 98.5%; mean difference, 15.5 mg/dL; Pearson's correlation coefficient [r(2)], 0.76, P < 0.0001). MARD was significantly lower in subjects who did not experience a sensor change (11.74% vs. 17.31%, P = 0.048). Also, a statistically significant negative correlation was found between serum bicarbonate levels and POC–CGM values (r = −0.34, P < 0.001). CONCLUSIONS: The severity of DKA has a major effect on reducing the accuracy of the CGM, especially during the first several days in the intensive care unit. The reduced accuracy appears to be related to acidosis, as reflected in the serum bicarbonate levels. Mary Ann Liebert, Inc., publishers 2023-08-01 2023-07-31 /pmc/articles/PMC10387156/ /pubmed/37155338 http://dx.doi.org/10.1089/dia.2023.0012 Text en © Esther Park and Minsun Kim, 2023; Published by Mary Ann Liebert, Inc. https://creativecommons.org/licenses/by/4.0/This Open Access article is distributed under the terms of the Creative Commons License (http://creativecommons.org/licenses/by/4.0 (https://creativecommons.org/licenses/by/4.0/) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited.
spellingShingle Original Articles
Park, Esther
Kim, Minsun
Clinical Use of Continuous Glucose Monitoring in Critically Ill Pediatric Patients with Diabetic Ketoacidosis
title Clinical Use of Continuous Glucose Monitoring in Critically Ill Pediatric Patients with Diabetic Ketoacidosis
title_full Clinical Use of Continuous Glucose Monitoring in Critically Ill Pediatric Patients with Diabetic Ketoacidosis
title_fullStr Clinical Use of Continuous Glucose Monitoring in Critically Ill Pediatric Patients with Diabetic Ketoacidosis
title_full_unstemmed Clinical Use of Continuous Glucose Monitoring in Critically Ill Pediatric Patients with Diabetic Ketoacidosis
title_short Clinical Use of Continuous Glucose Monitoring in Critically Ill Pediatric Patients with Diabetic Ketoacidosis
title_sort clinical use of continuous glucose monitoring in critically ill pediatric patients with diabetic ketoacidosis
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10387156/
https://www.ncbi.nlm.nih.gov/pubmed/37155338
http://dx.doi.org/10.1089/dia.2023.0012
work_keys_str_mv AT parkesther clinicaluseofcontinuousglucosemonitoringincriticallyillpediatricpatientswithdiabeticketoacidosis
AT kimminsun clinicaluseofcontinuousglucosemonitoringincriticallyillpediatricpatientswithdiabeticketoacidosis